Accuracy of total knee arthroplasty using the modified gap technique based on the bone gap: an evaluation of the bone gap with a distal femoral trial component

被引:0
|
作者
Goki Kamei
Shigeki Ishibashi
Koki Yoshioka
Satoru Sakurai
Hiroyuki Inoue
Masakazu Ishikawa
Yu Mochizuki
Nobuo Adachi
机构
[1] Hiroshima University,Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences
[2] Hiroshima Prefectural Hospital,Department of Orthopaedic Surgery
[3] Hiroshima University,Department of Artificial Joints and Biomaterials, Graduate School of Biomedical and Health Sciences
来源
关键词
Modified gap technique; Joint gap size; Joint gap inclination; Distal femoral trial component;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty
    Dennis, Douglas A.
    Komistek, Richard D.
    Kim, Raymond H.
    Sharma, Adrija
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 102 - 107
  • [32] Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances
    Blakeney, William
    Beaulieu, Yann
    Puliero, Benjamin
    Kiss, Marc-Olivier
    Vendittoli, Pascal-Andre
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1532 - 1541
  • [33] The Reliability of Navigation-guided Gap Technique in Total Knee Arthroplasty
    Han, Seung-Beom
    Nha, Kyung-Wook
    Yoon, Jung-Ro
    Lee, Dae-Hee
    Chae, In-Jung
    ORTHOPEDICS, 2008, 31 (10) : 40 - 44
  • [34] Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances
    William Blakeney
    Yann Beaulieu
    Benjamin Puliero
    Marc-Olivier Kiss
    Pascal-André Vendittoli
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1532 - 1541
  • [35] Relationship Between Femoral Component Rotation and Total Knee Flexion Gap Balance on Modified Axial Radiographs
    Hatayama, Kazuhisa
    Terauchi, Masanori
    Higuchi, Hiroshi
    Yanagisawa, Shinya
    Saito, Kenichi
    Takagishi, Kenji
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04): : 649 - 653
  • [36] Femoral Component Axial Rotation in the Gap-Balancing Approach to Total Knee Arthroplasty: Measurement by Computed Tomography
    Aihara, Andre Y.
    Cardoso, Fabiano N.
    Debiex, Pedro
    Castro, Antonio M.
    Luzo, Marcus V. M.
    Fernandes, Artur R. C.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1222 - +
  • [37] Staged Bilateral Total Knee Arthroplasty for Neglected Blount Disease Using a Gap Balancing Technique
    Taylor, Adam J.
    Carpenter, William
    Runner, Robert P.
    ARTHROPLASTY TODAY, 2021, 11 : 25 - 31
  • [38] Gap Balancing vs. Measured Resection Technique in Total Knee Arthroplasty
    Daines, Brian K.
    Dennis, Douglas A.
    CLINICS IN ORTHOPEDIC SURGERY, 2014, 6 (01) : 1 - 8
  • [39] Spacer-Based Gap Balancing in Total Knee Arthroplasty: Clinical Success with a Reproducible Technique
    Lavoie, Frederic
    JOURNAL OF KNEE SURGERY, 2017, 30 (08) : 798 - 806
  • [40] The Effect of Patellar Positioning on Femoral Component Rotation when Performing Flexion Gap Balancing Using a Tensioning Device for Total Knee Arthroplasty
    Ernstbrunner, Lukas
    Andronic, Octavian
    Grubhofer, Florian
    Jundt-Ecker, Michele
    Fucentese, Sandro F.
    JOURNAL OF KNEE SURGERY, 2022, 35 (02) : 185 - 189