Numerical investigation on the performance, sustainability, and efficiency of the deep borehole heat exchanger system for building heating

被引:0
|
作者
Chaofan Chen
Haibing Shao
Dmitri Naumov
Yanlong Kong
Kun Tu
Olaf Kolditz
机构
[1] Helmholtz Centre for Environmental Research (UFZ),Applied Environmental Systems Analysis
[2] Dresden University of Technology,Institute of Geology and Geophysics
[3] Freiberg University of Mining and Technology,Department of Environmental Sciences
[4] Chinese Academy of Sciences,undefined
[5] China University of Mining and Technology (Beijing),undefined
[6] University of California,undefined
来源
关键词
Deep borehole heat exchanger system; Performance; Sustainability; Temperature recovery ratio; Coefficient of system performance (CSP);
D O I
暂无
中图分类号
学科分类号
摘要
In densely inhabited urban areas, deep borehole heat exchangers (DBHE) have been proposed to be integrated with the heat pump in order to utilize geothermal energy for building heating purposes. In this work, a comprehensive numerical model was constructed with the OpenGeoSys (OGS) software applying the dual-continuum approach. The model was verified against analytical solution, as well as by comparing with the integrated heat flux distribution. A series of modeling scenarios were designed and simulated in this study to perform the DBHE system analysis and to investigate the influence of pipe materials, grout thermal conductivity, geothermal gradient, soil thermal conductivity, and groundwater flow. It was found that the soil thermal conductivity is the most important parameter for the DBHE system performance. Both thermally enhanced grout and the thermally insulated inner pipe will elevate the outflow temperature of the DBHE. With an elevated geothermal gradient of 0.04 °C m−1, the short-term sustainable specific heat extraction rate imposed on the DBHE can be increased to 150–200 W m−1. The quantification of maximum heat extraction rate was conducted based on the modeling of 30-year-long operation scenarios. With a standard geothermal gradient of 0.03 °C m−1, the extraction rate has to be kept below 125 W m−1 in the long-term operation. To reflect the electricity consumption by circulating pump, the coefficient of system performance (CSP) was proposed in this work to better quantify the system efficiency. With the typical pipe structure and flow rate specified in this study, it is found that the lower limit of the DBHE system is at a CSP value of 3.7. The extended numerical model presented in this study can be applied to the design and optimization of DBHE-coupled ground source heat pump systems.
引用
收藏
相关论文
共 50 条
  • [31] Thermal Performance Analysis and Multi-Factor Optimization of Middle-Deep Coaxial Borehole Heat Exchanger System for Low-Carbon Building Heating
    Liang, Mingshan
    Tu, Jianhua
    Zeng, Lingwen
    Zhang, Zhaoqing
    Cheng, Nan
    Luo, Yongqiang
    SUSTAINABILITY, 2023, 15 (21)
  • [32] Properly shortening design time scale of medium-deep borehole heat exchanger for high building heating performances with high computational efficiency
    Zhang, Sheng
    Liu, Jun
    Zhang, Xia
    Wang, Fenghao
    ENERGY, 2024, 290
  • [33] Multi-faceted performance analysis and optimization of a hybrid deep borehole heat exchanger heating system with latent heat thermal energy storage
    Wang, Zeyuan
    Wang, Fenghao
    Bai, Mengmeng
    Zhang, Sheng
    Xie, Zhentao
    Han, Baocheng
    Li, Yizhen
    Liu, Jun
    Cai, Wanlong
    Zhang, Yixuan
    Ma, Zhenjun
    ENERGY CONVERSION AND MANAGEMENT, 2024, 315
  • [34] Numerical investigation on heat extraction performance of a downhole heat exchanger geothermal system
    Shi, Yu
    Song, Xianzhi
    Li, Gensheng
    Li, Ruixia
    Zhang, Yiqun
    Wang, Gaosheng
    Zheng, Rui
    Lyu, Zehao
    APPLIED THERMAL ENGINEERING, 2018, 134 : 513 - 526
  • [35] Numerical investigation of a novel tube design for the geothermal borehole heat exchanger
    Bouhacina, Benamar
    Saim, Rachid
    Oztop, Hakan F.
    APPLIED THERMAL ENGINEERING, 2015, 79 : 153 - 162
  • [36] Heat transfer performance of a deep ground heat exchanger for building heating in long-term service
    Li, Chao
    Guan, Yanling
    Liu, Jianhong
    Jiang, Chao
    Yang, Ruitao
    Hou, Xueming
    RENEWABLE ENERGY, 2020, 166 : 20 - 34
  • [37] Numerical study on the heat transfer performance of coaxial shallow borehole heat exchanger
    Li G.
    Yang J.
    Zhu X.
    Shen Z.
    Energy and Built Environment, 2021, 2 (04): : 445 - 455
  • [38] Heat transfer performance of deep borehole heat exchanger with different operation modes
    Huang, Shuai
    Zhu, Ke
    Dong, Jiankai
    Li, Ji
    Kong, Weizheng
    Jiang, Yiqiang
    Fang, Zhaohong
    RENEWABLE ENERGY, 2022, 193 : 645 - 656
  • [39] Effects of building load characteristics on heating performance of the medium-deep U-type borehole heat exchanger coupled heat pumps: A coupled dynamic simulation
    Huang, Shuai
    Lin, Duotong
    Dong, Jiankai
    Li, Ji
    APPLIED ENERGY, 2025, 377
  • [40] Field Test and Numerical Simulation on Heat Transfer Performance of Coaxial Borehole Heat Exchanger
    Li, Peng
    Guan, Peng
    Zheng, Jun
    Dou, Bin
    Tian, Hong
    Duan, Xinsheng
    Liu, Hejuan
    ENERGIES, 2020, 13 (20)