Effects of increased slenderness in short heat-damaged RC columns confined with FRP composites

被引:0
|
作者
Hanan Al-Nimry
Mohammad Jawarneh
机构
[1] Jordan University of Science and Technology,Department of Civil Engineering
来源
Materials and Structures | 2017年 / 50卷
关键词
Circular RC columns; Heat-damaged columns; Slenderness; Confinement; Axial compression; Fiber reinforced polymers;
D O I
暂无
中图分类号
学科分类号
摘要
Twenty-six circular RC columns were tested under axial compression to explore the confinement effects of fiber reinforced polymer (FRP) sheets on the performance of heat-damaged short columns. The effects of increased column slenderness, level of heat-induced damage and stiffness of the FRP wrapping system were examined. Columns with l/r ratios of 12.5 and 18.75 were subjected to 500 °C for 1, 2 and 3 h. Eighteen heat-damaged columns were wrapped using unidirectional carbon and glass FRP sheets over their full heights. Test results showed that FRP wrapping significantly enhanced the axial resistance, toughness, ductility and deformation capacity of the heat-damaged columns but failed to restore their axial stiffness. Increasing the stiffness of the FRP jacket resulted in further enhancements in axial resistance, stiffness and toughness of the heat-damaged columns while adversely affecting their ductility. Carbon fiber reinforced polymer jackets with a confinement modulus of 0.65 GPa managed to reinstate, and even exceed, the original strength of heat-damaged columns. The effectiveness of FRP confinement of heat-damaged columns increased significantly with increasing damage level and decreasing column slenderness. The heat- and confinement-induced increases in column slenderness had no tangible effects on buckling stability of the test columns that were originally of low slenderness.
引用
收藏
相关论文
共 50 条
  • [31] An Experimental Investigation of Circular RC Columns with Various Slenderness Confined with CFRP Sheets
    Chikh, N.
    Benzaid, R.
    Mesbah, H.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (02): : 315 - 323
  • [32] Strength model for heat-damaged reinforced concrete circular columns confined with carbon fibre reinforced polymer fabrics
    Al-Kamaki, Yaman S. S.
    Al-Mahaidi, Riadh
    Bennetts, Ian
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2015, 34 (22) : 1833 - 1855
  • [33] An Experimental Investigation of Circular RC Columns with Various Slenderness Confined with CFRP Sheets
    N. Chikh
    R. Benzaid
    H. Mesbah
    Arabian Journal for Science and Engineering, 2012, 37 : 315 - 323
  • [34] Concentrically Loaded Circular RC Columns Partially Confined with FRP
    Sahar Y. Ghanem
    Issam E. Harik
    International Journal of Concrete Structures and Materials, 2018, 12
  • [35] Seismic Performance of FRP-Confined Circular RC Columns
    Wang, Z. Y.
    Wang, D. Y.
    Sheikh, S. A.
    Liu, J. T.
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 810 - +
  • [36] Modelling plastic hinge of FRP-confined RC columns
    Yuan, Fang
    Wu, Yu-Fei
    Li, Chun-Qing
    ENGINEERING STRUCTURES, 2017, 131 : 651 - 668
  • [37] Concentrically Loaded Circular RC Columns Partially Confined with FRP
    Ghanem, Sahar Y.
    Harik, Issam E.
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2018, 12 (01)
  • [38] Experimental investigation of damaged square short RC columns with low slenderness retrofitted by CFRP strips under axial load
    Ghoroubi, Rahim
    Mercimek, Omer
    Ozdemir, Anil
    Anil, Ozgur
    STRUCTURES, 2020, 28 : 170 - 180
  • [39] Axial behavior of RC columns retrofitted with FRP composites
    Ilki, Alper
    Peker, Onder
    Karamuk, Emre
    Demir, Cem
    Kumbasar, Nahit
    ADVANCES IN EARTHQUAKE ENGINEERING FOR URBAN RISK REDUCTION, 2006, 66 : 301 - +
  • [40] Comparative behaviour of hollow columns confined with FRP composites
    Kusumawardaningsih, Yuliarti
    Hadi, M. N. S.
    COMPOSITE STRUCTURES, 2010, 93 (01) : 198 - 205