Virtual placement of posterior C1-C2 transarticular screw fixation

被引:0
|
作者
Peter Spangenberg
Volker Coenen
Joachim Michael Gilsbach
Veit Rohde
机构
[1] Universitätsklinik RWTH,Neurochirurgische Klinik
来源
Neurosurgical Review | 2006年 / 29卷
关键词
Atlantoaxial instability; Transarticular screw fixation; 3D model; Virtual screw placement;
D O I
暂无
中图分类号
学科分类号
摘要
We wanted to evaluate how often safe and effective posterior C1-C2 transarticular screw placement is realizable when it is performed according to guidelines given in the literature. In 50 adult patients, computerized tomography scan data from C0 to C3 were transformed into a 3D spine model. Virtually, bilateral screws were placed from the medial third of the C2-C3 facet joint towards the rim of the C1 anterior arc parallel to midline. Three categories of virtual screw position were rated: optimal (virtual screw inside the C2 pars interarticularis, transversing the middle third of the atlantoaxial joint, and sparing the vertebral artery canal), suboptimal (virtual screw violating the C2 pars interarticularis, and/or transversing the lower or upper third of the C1-C2 joint, and sparing vertebral artery canal), and unacceptable (virtual screw breaching the vertebral artery canal). Optimal placement was seen in 74, suboptimal placement in 11, and unacceptable locations in 15 sites. We conclude that due to the variability of the anatomy of the upper cervical spine, optimal transarticular C1-C2 screw placement is not possible in up to 26%, and even hazardous in up to 15%.
引用
收藏
页码:114 / 117
页数:3
相关论文
共 50 条
  • [1] Virtual placement of posterior C1-C2 transarticular screw fixation
    Spangenberg, P
    Coenen, V
    Gilsbach, JM
    Rohde, V
    NEUROSURGICAL REVIEW, 2006, 29 (02) : 114 - 117
  • [2] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [3] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Kanat, A
    Aydin, Y
    NEUROSURGERY, 1999, 44 (03) : 687 - 688
  • [4] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Comment
    McCormick, PC
    NEUROSURGERY, 1998, 43 (02) : 280 - 280
  • [5] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Reply
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1999, 44 (03) : 688 - 689
  • [6] C1-C2 transarticular screw fixation for treatment of C1-C2 instability
    Coyne, TJ
    Fehlings, MG
    Martin, RJ
    JOURNAL OF CLINICAL NEUROSCIENCE, 1996, 3 (03) : 243 - 246
  • [7] Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation
    Jun, BY
    SPINE, 1998, 23 (15) : 1703 - 1707
  • [8] C1-c2 transarticular screw fixation: Technical aspects
    Haid, RW
    NEUROSURGERY, 2001, 49 (01) : 71 - 74
  • [9] C1-C2 transarticular screw fixation for atlantoaxial instability
    Fountas, KN
    Kapsalaki, EZ
    Karampelas, I
    Dimopoulos, VG
    Feltes, CH
    Kassam, MA
    Boev, AN
    Johnston, KW
    Smisson, HF
    Troup, EC
    Robinson, JS
    SOUTHERN MEDICAL JOURNAL, 2004, 97 (11) : 1042 - 1048
  • [10] Posterior C1-C2 transarticular screw fixation for instability of the C0-C2 complex
    Martín-Ferrer, S
    Rimbau, J
    Joly, MC
    Teruel, J
    Pont, J
    NEUROCIRUGIA, 2000, 11 (01): : 43 - 49