Thermoluminescence dosimetry for in-vivo verification of high dose rate brachytherapy for prostate cancer

被引:0
|
作者
R. Das
W. Toye
T. Kron
S. Williams
G. Duchesne
机构
[1] RMIT University,Department of Applied Physics
[2] Radiation Oncology Victoria,School of Medicine and Health Sciences
[3] University of Melbourne,Department of Physical Sciences
[4] Peter MacCallum Cancer Centre,undefined
关键词
HDR brachytherapy; prostate cancer; in-vivo dosimetry; TLD; treatment planning; rectum dose; urethra dose;
D O I
暂无
中图分类号
学科分类号
摘要
It was the aim of the study to verify dose delivered in urethra and rectum during High Dose Rate brachytherapy boost (HDRBB) of prostate cancer patients. During the first fraction of HDRBB measurement catheters were placed in the urethra and rectum of prostate cancer patients. These contained LiF:Mg,Ti Thermoluminescence Dosimetry (TLD) rods of 1mm diameter, with up to 11 detectors positioned every 16 mm separated by radio-opaque markers. A Lorentzian peak function was used to fit the data. Measurements from 50 patients were evaluated and measured doses were compared with predictions from the treatment planning system (Plato Vs 13.5 to 14.1). Prospective urinary and rectal toxicity scores were collected following treatment. In more than 90% of cases, the Lorentzian peak function provided a good fit to both experimental and planning urethral data (r2 > 0.9). In general there was good agreement between measured and predicted doses with the average difference between measured and planned maximum dose being 0.1Gy. No significant association between dose and any clinical endpoints was observed in 43 patients available for clinical evaluation. An average inferior shift of 2 mm between the plan and the measurement performed approximately 1 hour after the planning CT scan was found for the dose distribution in the cohort of patients for the urethra measurements. Rectal measurements proved to be more difficult to interpret as there is more variability of TLD position between planning and treatment. TLD in-vivo measurements are easily performed in urethra and rectum during HDR brachytherapy of prostate patients. They verify the delivery and provide information about the dose delivered to critical structures. The latter may be of particular interest if higher doses are to be given per fraction such as in HDR monotherapy.
引用
收藏
页码:178 / 184
页数:6
相关论文
共 50 条
  • [21] High dose rate brachytherapy in the treatment of prostate cancer
    Frank Vicini
    Carlos Vargas
    Gary Gustafson
    Gregory Edmundson
    Alvaro Martinez
    World Journal of Urology, 2003, 21 : 220 - 228
  • [22] High dose rate brachytherapy in the treatment of prostate cancer
    Rodriguez, RR
    Demanes, J
    Altieri, GA
    HEMATOLOGY-ONCOLOGY CLINICS OF NORTH AMERICA, 1999, 13 (03) : 503 - +
  • [23] In-vivo diode dosimetry for IMRT treatment dose verification
    Tong, S
    Li, T
    Lei, S
    Grant, D
    Mazzilli, T
    Papadopoulos, D
    Chu, K
    MEDICAL PHYSICS, 2005, 32 (06) : 1984 - 1984
  • [24] High dose rate brachytherapy of localized prostate cancer
    Deger, S
    Boehmer, D
    Türk, I
    Roigas, J
    Wernecke, KD
    Wiegel, T
    Hinkelbein, W
    Dinges, S
    Budach, V
    Loening, SA
    EUROPEAN UROLOGY, 2002, 41 (04) : 420 - 426
  • [25] Radiotherapy dose verification using in-vivo dosimetry systems
    Alshaikh, S.
    Kinsara, A. A.
    Moftah, B.
    Altaher, Z.
    Naseem, M.
    Safar, W.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S515 - S515
  • [26] High dose rate brachytherapy in the treatment of prostate cancer
    Vicini, F
    Vargas, C
    Gustafson, G
    Edmundson, G
    Martinez, A
    WORLD JOURNAL OF UROLOGY, 2003, 21 (04) : 220 - 228
  • [27] Real-time in-vivo dosimetry in HDR prostate brachytherapy
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S27 - S28
  • [28] Real-time in-vivo dosimetry for HDR prostate brachytherapy
    Mamo, A.
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Okkalides, D.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S85 - S86
  • [29] Dosimetry of anal radiation in high-dose brachytherapy for prostate cancer
    Kalkner, Karl Mikael
    Bengtsson, Emil
    Eriksson, Simone
    Holmberg, Carina
    Nilsson, Sten
    Levitt, Seymour
    Lundell, Marie
    BRACHYTHERAPY, 2007, 6 (01) : 49 - 52
  • [30] Dosimetry and cancer control after low-dose-rate prostate brachytherapy
    Lee, WR
    DeGuzman, AF
    McMullen, KP
    McCullough, DL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01): : 52 - 59