Aortic strain in bicuspid aortic valve: an analysis

被引:0
|
作者
Tomás Carlos
André Azul Freitas
Patrícia Marques Alves
Rui Martins
Lino Gonçalves
机构
[1] Universidade de Coimbra,Faculty of Medicine
[2] Centro Hospitalar e Universitário de Coimbra,Department of Cardiology
关键词
Bicuspid aortic valve; Speckle‐tracking echocardiography; Strain; Aortic valve insufficiency; Prognosis;
D O I
暂无
中图分类号
学科分类号
摘要
Bicuspid aortic valve (BAV) is monitored by transthoracic echocardiography and computed tomography (CT) angiography. However, it does not have any early marker of disease progression. This study evaluated speckle-tracking echocardiography (STE) aortic and left ventricular (LV) strain prognostic values, their discriminative power, and their correlation with the degree of valvular regurgitation. We conducted a retrospective analysis of a prospectively enrolled cohort of 45 diagnosed with BAV and 20 gender and age matched controls. We performed 2D-STE aortic and LV strain analysis of the selected population. The cohort was followed-up during a median period of 19.9 months (IQR 12.9–25.2), and outcomes (hospital admission for heart failure (HF), aortic valve replacement (AVR), and death) were determined. The mean patient age was 46.6 ± 15.5 years and 80 % were male. LV indexed volumes and aortic diameter were higher in BAV patients. LV global longitudinal strain (GLS) was impaired (p < 0.001) and aortic GLS was significantly augmented (p = 0.027) in BAV patients. Aortic global circumferential strain (GCS) did not vary between groups. Aortic diameter was the best parameter related to BAV (AUC 0.92) and aortic GLS was best correlated with significant AR (AUC 0.76). AVR was the only outcome observed and its only predictor was indexed LV end-diastolic volume. BAV had impaired LV-GLS values. Aortic GLS was abnormally augmented in BAV patients, which might reflect higher aortic diameters that distorted strain calculations. STE aortic strain is related to AR but does not appear to be a reliable predictor of surgery in BAV patients, at 19 months.
引用
收藏
页码:2399 / 2408
页数:9
相关论文
共 50 条
  • [31] Transcatheter aortic valve replacement in bicuspid aortic valve patients
    Fernando Nascimento Ferreira, F.
    Rodrigues, I.
    Figueiredo, M.
    Teixeira, B.
    Albuquerque, F.
    Carvalheiro, R.
    Mendonca, T.
    Grazina, A.
    Cacela, D.
    Ramos, R.
    Fiarresga, A.
    Cruz Ferreira, R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 553 - 553
  • [32] AORTIC-VALVE PROLAPSE IN BICUSPID AORTIC-VALVE
    STEWART, WJ
    KING, ME
    LIBERTHSON, RR
    WEYMAN, AE
    CIRCULATION, 1982, 66 (04) : 162 - 162
  • [33] Transcatheter aortic valve replacement for bicuspid aortic valve stenosis
    Kayani, Waleed T.
    Blaustein, Alvin
    Denktas, Ali
    Jneid, Hani
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 2018, 85 (10) : 786 - 788
  • [34] Transcatheter Aortic Valve Replacement in a Bicuspid Aortic Valve With Type A Aortic Dissection
    Putthapiban, Prapaipan
    Alani, Anas
    Jutzy, Kenneth
    Abudayyeh, Islam
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (18) : E243 - E245
  • [35] Tricuspidalization of a bicuspid aortic valve with severe aortic valve insufficiency
    Kalangos, A
    Beghetti, M
    Christenson, JT
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (04): : 964 - 966
  • [36] Transcatheter aortic valve replacement in bicuspid aortic valve disease
    Kochman, Janusz
    Rymuza, Bartosz
    Huczek, Zenon
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (06) : 594 - 602
  • [37] Transcatheter aortic valve implantation in bicuspid aortic valve stenosis
    Perlman, Gidon Y.
    Blanke, Philipp
    Webb, John G.
    EUROINTERVENTION, 2016, 12 : Y42 - Y45
  • [39] TRANSCATHETER AORTIC VALVE REPLACEMENT IN BICUSPID AORTIC VALVE DISEASE
    Mylotte, Darren
    Lefevre, Thierry
    Watanabe, Yusuke
    Sondergaard, Lars
    Windecker, Stephan
    Bosmans, Johan
    Tchetche, Didier
    Kornowski, Ran
    Modine, Thomas
    Sinning, Jan-Malte
    O'Sullivan, Crochan
    Barbanti, Marco
    Codner, Pablo
    Dorfmeister, Magdalena
    Martucci, Joseph
    Wenaweser, Peter
    Tamburino, Corrado
    Grube, Eberhard
    Webb, John
    Lange, Ruediger
    Piazza, Nicolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1939 - A1939
  • [40] Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve with Aortic Stenosis: a Meta-Analysis and Trial Sequential Analysis
    Chan, Jeffrey Shi Kai
    Singh, Sukhdeep
    Eriksen, Peter
    Tsui, Lok Him
    Harky, Amer
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 37 (01) : 88 - 98