Switching transients caused by vacuum circuit breakers in collection grids of offshore wind farms

被引:5
|
作者
Tao, Jiayuan [1 ]
Yang, Qing [2 ]
Zheng, Xuena [3 ]
He, Yanxiao [4 ]
Wang, Ruixue [3 ]
Lv, Hefei [5 ]
Zhang, Jie [6 ]
机构
[1] Chongqing Coll Elect Engn, Chongqing, Peoples R China
[2] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing, Peoples R China
[3] Chongqing Metropolitan Coll Sci & Technol, Chongqing, Peoples R China
[4] Chongqing Univ Technol, Liangjiang Int Coll, Chongqing, Peoples R China
[5] NR Elect Co Ltd, Nanjing, Peoples R China
[6] State Grid Chongqing Elect Power Co, Chongqing, Peoples R China
关键词
multiple prestrike and reignition; offshore wind farms; overvoltage; suppression measure; switching transients; vacuum circuit breaker;
D O I
10.1002/we.2643
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, transients that can occur in the collection grids of offshore wind farms were investigated. On the basis of the multiple prestrike and reignition model that can reflect the actual operation of a vacuum circuit breaker (VCB), a switching transient simulation model of a typical offshore wind farm was built. The developed model included a VCB, a transformer, a cable, and an arrester. Issues concerning the closing time, length of the feeder, and topology of the collection grid were discussed. Results showed that the relationship between overvoltage amplitude and closing time was approximately sinusoidal and the maximum value was obtained when the closing time was near the peak of the power source. In addition, the overvoltage at the end of a feeder terminal was the largest among all of the transformer overvoltages of the same feeder. The overvoltage of the main transformer and that of the transformer located at the end of a feeder decreased slowly with the increase in feeder length during the closing of VCB. However, these overvoltages were positively related to feeder length during the opening of VCB. The star topology was superior to the other topologies in terms of coping with the overvoltage caused by switching transients. The effectiveness of a suppression measure, namely, installation of a resistance-capacitor filter, was also verified.
引用
收藏
页码:1501 / 1516
页数:16
相关论文
共 50 条
  • [21] Analysis of Restrike Overvoltage of Circuit Breakers in Wind Farms
    Zhou, Qi Bin
    Zhao, Yang
    Cheng, Yu
    Bian, Xiao Yan
    Liu, Fei Fan
    2015 IEEE INTERNATIONAL CONFERENCE ON APPLIED SUPERCONDUCTIVITY AND ELECTROMAGNETIC DEVICES (ASEMD), 2015, : 232 - 233
  • [22] High Frequency Transients Propagation and the Multiple Reflections Effect in Collection Grids for Offshore Wind Parks
    Villar, F. S.
    Reza, M.
    Srivastava, K.
    da Silva, L. C. P.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [23] Synchronous Capacitor Bank Switching with Vacuum Circuit Breakers
    Schellekens, Hans
    Bono, Mathieu
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 2, 2018, : 567 - 570
  • [24] Faults in the collection grid of offshore wind farms
    Lunow, Morten Erlandsson
    Holboell, Joachim
    Henriksen, Mogens
    2008 ANNUAL IEEE STUDENT PAPER CONFERENCE, 2008, : 116 - +
  • [25] Control and design of DC grids for offshore wind farms
    Meyer, Christoph
    Hoeing, Markus
    Peterson, Anders
    De Doncker, Rik W.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (06) : 1475 - 1482
  • [26] SWITCHING SURGE AND APPLICATION OF VACUUM CONTACTORS AND VACUUM CIRCUIT-BREAKERS
    OHASHI, H
    KOIKE, H
    OKAWA, M
    IMAJYO, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (03): : 762 - 762
  • [27] Review on DC collection grids for offshore wind farms with high-voltage DC transmission system
    Musasa, Kabeya
    Nwulu, Nnamdi I.
    Gitau, Michael N.
    Bansal, Ramesh C.
    IET POWER ELECTRONICS, 2017, 10 (15) : 2104 - 2115
  • [28] Interconnection of Offshore Wind Farms using Variable Frequency in Offshore AC Grids
    Sortsi, Dimitra-Chrysie I.
    Gkavanoudis, Spyros I.
    Demoulias, Charis S.
    2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [29] Field Experiments on Overvoltage Caused by 12-kV Vacuum Circuit Breakers Switching Shunt Reactors
    Yang, Qing
    Zhang, Zhaohui
    Sima, Wenxia
    Yang, Ming
    Wei, Gang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (02) : 657 - 664
  • [30] Analysis of Transients in Simulations of Vacuum Circuit Breaker Switching
    Bongiolo, Guilherme Grazziotin
    Zanetta Junior, Luiz Cera
    2018 13TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2018, : 354 - 360