High-Precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging

被引:100
|
作者
Shi, Xuetao [1 ]
Li, Weichen [1 ]
You, Fusheng [1 ]
Huo, Xuyang [2 ]
Xu, Canhua [1 ]
Ji, Zhenyu [1 ]
Liu, Ruigang [1 ]
Liu, Benyuan [1 ]
Li, Yandong [1 ]
Fu, Feng [1 ]
Dong, Xiuzhen [1 ]
机构
[1] Fourth Mil Med Univ, Sch Biomed Engn, Dept Biomed Engn, Xian 710032, Shaanxi, Peoples R China
[2] Jilin Med Coll, Fac Biomed Engn, Jilin 132013, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrical impedance; brain imaging; data acquisition; imaging monitoring; EIT SYSTEM; CALIBRATION; ELECTRODES; DESIGN; EEG;
D O I
10.1109/JSEN.2018.2836336
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In electrical impedance tomography (EIT), it is difficult to obtain the intracranial impedance due to the highly resistive skull enclosing the brain. Therefore, a high-precision data acquisition system is required for brain EIT. In this paper, we used a high-precision digital synthesis method and a digital demodulation technique with high noise immunity to eliminate random errors. Moreover, we focused on two problems encountered during EIT data acquisition: 1) the shunt effect on the excitation current due to the distributed capacitance between electrodes and ground and 2) high common-mode voltages in the boundary measurements. We designed a new electrode interface to reduce the influence of the distributed capacitance and a programmable current source to accurately compensate for the excited current. We also proposed a new voltmeter circuit with improved CMRR. Overall, this EIT data acquisition system can produce a programmable current with SNR greater than 89 dB. It can also measure the voltage difference precisely with CMRR higher than 75 dB with a 1-k Omega impedance imbalance. The results on a calibration model show that this system has a high SNR of 83 dB and a low reciprocity error of 0.125%. In addition, EIT imaging results were acquired using a brain physical phantom. The system can detect small disturbances of 0.35% in volume (1.99% of the cross-sectional area) and 17% in resistivity. Experiments on healthy volunteers also suggest that small intracranial impedance variations due to temporary occlusion and reperfusion of the unilateral carotid artery may be monitored by the system.
引用
收藏
页码:5974 / 5984
页数:11
相关论文
共 50 条
  • [21] Study on human brain impedance imaging using electrical impedance tomography
    Xu, GZ
    Dong, GY
    Yan, WL
    Yang, QX
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 378 - 380
  • [22] Design of the high-speed, high-precision and large-scale data acquisition system
    Hou, XM
    Wang, XH
    Tong, L
    2004 7TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS, VOLS 1-3, 2004, : 563 - 566
  • [23] The design of acquisition hardware system based on electrical impedance tomography
    Xu, GZ
    Yu, Q
    Liu, ZH
    Xing, QG
    Zhang, Q
    Yan, WL
    APPLIED ELECTROMAGNETICS (III), 2001, 10 : 471 - 474
  • [24] Design and Implementation of Embedded Remote Control System in High-precision Time Data Acquisition
    Fang Zhao
    Zhao Jianjun
    Tang Haifeng
    Wu Guangmin
    2015 11TH INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND SECURITY (CIS), 2015, : 125 - 128
  • [25] Lung Imaging Acquisition with Electrical Impedance Tomography: Tackling Common Pitfalls
    Santiago, Roberta Ribeiro De Santis
    Xin, Yi
    Gaulton, Timothy G.
    Alcala, Glasiele
    Leon Bueno de Camargo, Erick Dario
    Cereda, Maurizio
    Passos Amato, Marcelo Britto
    Berra, Lorenzo
    ANESTHESIOLOGY, 2023, 139 (03) : 329 - 341
  • [26] High-Precision Synchronous Implementation during Seismic Data Acquisition
    Wang, Qi
    Deng, Ming
    Zhang, Qisheng
    Yang, Rui
    ACHIEVEMENTS IN ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL BASED ON INFORMATION TECHNOLOGY, PTS 1 AND 2, 2011, 171-172 : 764 - 768
  • [27] Research on a high-precision delay circuit in data acquisition systems
    School of Mechanical, Electronic and Information Engineering, China University of Mining and Technology, Beijing 100083, China
    不详
    J. China Univ. Min. Technol., 2006, 2 (171-174):
  • [28] A broadband high-frequency electrical impedance tomography system for breast Imaging
    Halter, Ryan J.
    Hartov, Alex
    Paulsen, Keith D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (02) : 650 - 659
  • [29] Electrical impedance tomography for high speed chest imaging
    Lionheart, WRB
    Lidgey, FJ
    McLeod, CN
    Paulson, KS
    Pidcock, MK
    Shi, Y
    PHYSICA MEDICA, 1997, 13 : 247 - 249
  • [30] A complex programmable logic device-based high-precision electrical capacitance tomography system
    Zhou, Haili
    Xu, Lijun
    Cao, Zhang
    Liu, XiaoLei
    Liu, Shi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)