Nonproportionality of electron response using CCT: Plastic scintillator

被引:17
|
作者
Limkitjaroenporrn, P. [2 ]
Kaewkhao, J. [1 ]
Limsuwan, P. [2 ,3 ]
Chewpraditkul, W. [2 ]
机构
[1] Nakorn Pathom Rajabhat Univ, Fac Sci & Technol, Ctr Excellence Glass Technol & Mat Sci, Nakorn 73000, Pathom, Thailand
[2] King Mongkuts Univ Technol, Fac Sci, Dept Phys, Bangkok 10140, Thailand
[3] Thailand Ctr Excellence Phys, CHE, Bangkok 10400, Thailand
关键词
Plastic scintillator; Electron response; Energy resolution;
D O I
10.1016/j.apradiso.2010.02.015
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The scintillation response of a plastic scintillator (NE102) has been characterized using compton coincidence technique. The coincidence technique allowed detection of nearly monoenergetic internal electrons resulting from the scattering of incident 662 key gamma-rays within a primary NE102 detector. Scattered gamma-rays were detected using a secondary Nal(Tl) detector in a coincidence mode. The electron response nonproportionality of NE102 plastic scintillator was measured using this technique for electron energies ranging from 28 to 436 key, by varying the scattering angle. The NE102 showed a good proportionality of light yield within 3% at energies between 90 and 436 key. Below 90 keV, the light yield decreases by about 20% upon lowering the electron energy to 28 keV. The electron energy resolution of NE102 was also measured using this technique in the energy range from 68 to 436 key. It has been found that the energy resolution varies from 25.2% at 68 key to 11.8% at 436 key. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1780 / 1784
页数:5
相关论文
共 50 条
  • [11] Response of plastic scintillator to gamma sources
    Tajudin, Suffian M.
    Namito, Y.
    Sanami, T.
    Hirayama, H.
    APPLIED RADIATION AND ISOTOPES, 2020, 159
  • [12] The response of plastic scintillator to protons and deuterons
    OReilly, GV
    Kolb, NR
    Pywell, RE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03): : 745 - 749
  • [13] Response of plastic scintillator to protons and deuterons
    Nucl Instrum Methods Phys Res Sect A, 3 (745):
  • [14] Nonproportionality of Scintillator Detectors: Theory and Experiment. II
    Payne, Stephen A.
    Moses, William W.
    Sheets, Steven
    Ahle, Larry
    Cherepy, Nerine J.
    Sturm, Benjamin
    Dazeley, Steven
    Bizarri, Gregory
    Choong, Woon-Seng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (06) : 3392 - 3402
  • [15] Light yield nonproportionality component of scintillator energy resolution
    Univ of Cincinnati, Cincinnati, United States
    IEEE Trans Nucl Sci, 3 pt 1 (512-517):
  • [16] On possible temperature dependence of plastic scintillator response
    Beddar, Sam
    MEDICAL PHYSICS, 2012, 39 (10) : 6522 - 6522
  • [17] A MODEL FOR THE OPTICAL-RESPONSE OF PLASTIC SCINTILLATOR
    INTROZZI, G
    RATTI, SP
    COTEUS, PW
    CULY, S
    CUMALAT, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (01): : 161 - 166
  • [18] Measurement of the plastic scintillator response in the magnetic field
    Balalykin, NI
    Golutvin, IA
    Kochetov, OI
    Kuznetsov, VD
    Makoveev, VK
    Myshinski, GV
    Novgorodov, AF
    Shabratov, VG
    Volodko, AG
    Klimenko, VS
    Kurilin, AS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (03): : 286 - 292
  • [19] Plastic fiber scintillator response to fast neutrons
    Danly, C. R.
    Sjue, S.
    Wilde, C. H.
    Merrill, F. E.
    Haight, R. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [20] RADIOACTIVE SENSOR USING PLASTIC SCINTILLATOR
    TANAKA, A
    KOJIMA, Y
    KOBUNSHI RONBUNSHU, 1993, 50 (06) : 523 - 527