Value of C3d assay and IgG subclass in the prediction of the flow cytometry cross-match result for renal transplantation

被引:3
|
作者
Contreras, Alan G. [1 ]
Casillas-Abundis, Aurora [1 ]
Alberu, Josefina [1 ,5 ]
Llorente, Luis [2 ]
Lima, Guadalupe [2 ]
Arvizu, Adriana [3 ]
de Santiago, Adrian [3 ]
Vilatoba, Mario [1 ]
Granados, Julio [1 ]
Morales-Buenrostro, Luis E. [4 ]
Cruz, Rodrigo [1 ]
Arreola-Guerra, Jose M. [1 ,5 ]
机构
[1] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Transplantat, Vasco Quiroga 15,Colonia Belisario Dominguez, Mexico City 14080, DF, Mexico
[2] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Immunol & Rheumatol, Vasco Quiroga 15,Colonia Belisario Dominguez, Mexico City 14080, DF, Mexico
[3] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Histocompatibil Lab, Vasco Quiroga 15,Colonia Belisario Dominguez, Mexico City 14080, DF, Mexico
[4] Inst Nacl Ciencias Med & Nutr Salvador Zubiran, Dept Nephrol Mineral Metab, Vasco Quiroga 15,Colonia Belisario Dominguez, Mexico City 14080, DF, Mexico
[5] Inst Mexicano Invest Nefrol, AC Juan Badiano 1,Colonia Belisario Dominguez, Mexico City 14080, DF, Mexico
关键词
DONOR-SPECIFIC ANTIBODIES; ANTI-HLA ANTIBODIES; RISK STRATIFICATION; ALLOGRAFT SURVIVAL; MEDIATED REJECTION; GRAFT LOSS; RECIPIENTS; C1Q; STRENGTH;
D O I
10.1016/j.trim.2018.05.002
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The aim of this study is to compare the association and the predictive capacity of DSA MFI, complement fixing capacity (C3d assay) and IgG subclasses determination in the prediction of FCxM result. Methods: We used cryopreserved (-70C) sera from potential renal transplant recipients, containing DSA against their respective potential donors. All patients showed negative AHG-CDC CxM and either positive or negative FCxM. Class I and Class II HLA-DSA were determined by Luminex SAB. C3d were detected by Luminex (Lifecodes (R) Immucor), DSA IgG 1-4 subclasses were evaluated using monoclonal antibodies specific for IgG subclasses (Luminex). Results: 93 donor/recipient tests were evaluated; 32 (35.9%) patients presented at least one C3d + Ab, of which only 11 (11.8%) were donor specific. At least one IgG subclass was identified in 45 samples (48.3%). Twenty-seven FCxM tests (29%) were positive. On multivariate analysis HLA mismatches, the IgG subclass detection, DSA MFI and class II PRA remain associated to FCxM whereas C3d + Ab was not associated. For the FCxM prediction, the IgG subclass detection in combination with the DSA-MFI > 2800, had the best negative predictive value 93.9 (CI 95%, 84.2-100). Conclusion: Neither the C3d assay nor the IgG subclasses detection alone had an adequate predictive capacity for the FCxM. In the absence of IgG subclass detection and DSA-MFI < 2000, the probability of a negative FCxM was near 94%.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [31] RENAL-TRANSPLANTATION DESPITE A POSITIVE ANTIGLOBULIN CROSS-MATCH WITH AND WITHOUT PROPHYLACTIC OKT3
    DAFOE, DC
    BROMBERG, JS
    GROSSMAN, RA
    TOMASZEWSKI, JE
    ZMIJEWSKI, CM
    PERLOFF, LJ
    NAJI, A
    ASPLUND, MW
    ALFREY, EJ
    SACK, M
    ZELLERS, L
    KEARNS, J
    BARKER, CF
    TRANSPLANTATION, 1991, 51 (04) : 762 - 768
  • [32] Effect of ABO incompatibility on T-cell flow cytometry cross-match results prior to living donor kidney transplantation
    Lindemann, M.
    Lenz, V.
    Nyadu, B.
    Heinemann, F. M.
    Heinold, A.
    Guberina, H.
    Eisenberger, U.
    Lachmann, N.
    Schoenemann, C.
    Kribben, A.
    Paul, A.
    Horn, P. A.
    Witzke, O.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2018, 94 (04) : 623 - 630
  • [33] CORRELATION BETWEEN FLOW-CYTOMETRY CROSS-MATCH RESULTS AND SUBSEQUENT REJECTION EPISODES IN CADAVER RENAL-ALLOGRAFT RECIPIENTS
    LAZDA, VA
    POLLAK, R
    HUMAN IMMUNOLOGY, 1986, 17 (02) : 148 - 148
  • [34] EFFECT OF FLOW-CYTOMETRY, COMPLEMENT-DEPENDENT CYTOTOXICITY, AND AUTO CROSS-MATCH ON CADAVERIC RENAL-TRANSPLANT OUTCOME
    CHRISTIAANS, M
    VANDENBERGLOONEN, E
    TENHAAFT, A
    NIEMAN, F
    VANHOOFF, J
    TRANSPLANTATION PROCEEDINGS, 1995, 27 (01) : 1028 - 1030
  • [35] Flow cytometry is more sensitive at detecting RBC-associated C3d than the tube agglutination assay.
    Stroncek, DF
    Njoroge, JM
    Procter, JL
    Griffith, LM
    Childs, RW
    Miller, J
    BLOOD, 2001, 98 (11) : 61A - 62A
  • [36] REDUCTION IN EARLY CADAVERIC RENAL-ALLOGRAFT FAILURE IN PATIENTS WITH POSITIVE FLOW-CYTOMETRY CROSS-MATCH BY PRETRANSPLANT ALG THERAPY
    NORIN, A
    SADEGHIAN, M
    SUMRANI, N
    CACCIARELLI, T
    SOMMER, B
    HONG, J
    HUMAN IMMUNOLOGY, 1993, 37 : 71 - 71
  • [37] Does the C1q Assay Predict the Result of Lymphocyte Flow Cross-Match (FCxM) in Potential Renal Transplant Recipients With HLA-DSA and AHG-CDC CxM negative?
    Arreola-Guerra, J.
    de Santiago, A.
    Arvizu, A.
    Gonzalez-Tableros, N.
    Lopez, M.
    Vilatoba, M.
    Morales-Buenrostro, L.
    Alberu, J.
    Castelan, N.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2015, 15
  • [38] THE USE OF THE T-CELL FLOW-CYTOMETRY CROSS-MATCH TO EVALUATE THE SIGNIFICANCE OF POSITIVE B-CELL SEROLOGIC CROSS-MATCHES IN CADAVERIC DONOR RENAL-TRANSPLANTATION
    THISTLETHWAITE, JR
    HEFFRON, TG
    STEVENS, L
    BUCKINGHAM, M
    STUART, JK
    STUART, FP
    TRANSPLANTATION PROCEEDINGS, 1990, 22 (04) : 1897 - 1898
  • [39] LIVING DONOR KIDNEY TRANSPLANTATION IN T-CELL FLOW CYTOMETRY CROSS-MATCH POSITIVE PATIENTS AFTER DESENSITIZATION WITHOUT INTRAVENOUS IMMUNOGLOBULIN
    Park, Jae Berm
    Kim, Young Hoon
    Song, Ki Byung
    Chung, Young Soo
    Jung, Joo Hee
    Oh, Heung-Bum
    Kwon, Seog-Woon
    Park, Su Kil
    Kim, Song-Cheol
    Han, Duck Jong
    TRANSPLANT INTERNATIONAL, 2011, 24 : 335 - 335
  • [40] Relationship between the flow cytometry cross-match and labscreen only-defined donor-specific antibodies (DSA) in renal transplant patients
    Singleton, Deborah
    Rees, Margaret T.
    Darke, Christopher
    TISSUE ANTIGENS, 2010, 75 (05): : 575 - 576