Design of an x-ray FEL undulator

被引:0
|
作者
Carr, R [1 ]
机构
[1] Stanford Linear Accelerator Ctr, Stanford Synchrotron Radiat Lab, Stanford, CA 94309 USA
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An undulator designed to be used far an x-ray free electron laser has to meet a set of stringent requirements. With no optical cavity, an x-ray FEL operates in the single pass Self Amplified Spontaneous Emission (SASE) mode; an electron macropulse is microbunched by an undulator and the radiation it creates. The microbunched pulse emits spontaneous radiation and coherent FEL radiation, whose power may reach saturation in a sufficiently long and perfect undulator. The pulse must have low emittance and high current, and its trajectory in the undulator must keep the radiation and the pulse together with a very high degree of overlap. In this paper we use the case of the Linear Coherent Light Source (LCLS) x-ray free electron laser to illustrate design concepts for long free electron laser undulators. [1,2] The LCLS is intended to create 1.5 Angstrom x-rays using an electron beam with 15 GeV energy, 1.5 pi mm-mrad normalized emittance, 3400 A peak current, and 280 fsec FWHM bunch duration. According to our simulations, this 2 sigma(r) = 65 mm rms diameter beam must overlap its radiation with a walkoff of no more than 5 mu m RMS per 11.7 meter field gain length for efficient gain. The energy spread of the beam is sigma(E) = 0.0002 E-L. This places severe limitations on the magnetic field errors and on mechanical tolerances. In this paper we shall discuss how to meet these requirements.
引用
收藏
页码:143 / 154
页数:12
相关论文
共 50 条
  • [41] Influence of higher harmonics of the undulator in X-ray polarimetry and crystal monochromator design
    Marx-Glowna, Berit
    Schulze, Kai S.
    Uschmann, Ingo
    Kaempfer, Tino
    Weber, Guenter
    Hahn, Christoph
    Wille, Hans-Christian
    Schlage, Kai
    Roehlsberger, Ralf
    Foerster, Eckhart
    Stoehlker, Thomas
    Paulus, Gerhard G.
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1151 - 1154
  • [42] Exploiting undulator radiation for X-ray interferometry
    Talman, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 519 - 542
  • [43] XAFS using tunable X-ray undulator
    Oyanagi, H.
    Ishii, M.
    Lee, Chul-Ho
    Saini, N.L.
    Kuwahara, Y.
    Saito, A.
    Hashimato, H.
    Izumi, Y.
    Kiri, M.
    Jinno, M.
    Ueno, Y.
    Denshi Gijutsu Sogo Kenkyusho Iho/Bulletin of the Electrotechnical Laboratory, 1999, 62 (09): : 9 - 20
  • [44] Progress toward a soft X-ray FEL
    Pellegrini, C.
    Nuclear instruments and methods in physics research, 1988, 272 (1-2): : 364 - 367
  • [45] AMO instrumentation for the LCLS X-ray FEL
    Bozek, J. D.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2009, 169 : 129 - 132
  • [46] A compact laser FEL in a X-ray regime
    Kumada, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (01): : 41 - 45
  • [47] Undulator systems for the TESLA X-FEL
    Pflüger, J
    Tischer, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2): : 388 - 393
  • [48] The x-ray FEL: An experimenter's dilemma
    McPherson, A
    X-RAY FEL OPTICS AND INSTRUMENTATION, 2001, 4143 : 20 - 25
  • [49] Optimization of an X-ray SASE-FEL
    Pellegrini, C
    Reiche, S
    Rosenzweig, J
    Schroeder, C
    Varfolomeev, A
    Tolmachev, S
    Nuhn, HD
    PHYSICS OF, AND SCIENCE WITH, THE X-RAY FREE-ELECTRON LASER, 2001, 581 : 221 - 228
  • [50] Quantum limit in X-ray FEL theory
    Smetanin, IV
    LASER PHYSICS, 1997, 7 (02) : 318 - 322