Accuracy of glaucoma detection with frequency-doubling perimetry

被引:75
|
作者
Trible, JR [1 ]
Schultz, RO [1 ]
Robinson, JC [1 ]
Rothe, TL [1 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Milwaukee, WI 53226 USA
关键词
D O I
10.1016/S0002-9394(00)00354-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the accuracy of glaucoma detection by frequency-doubling perimetry. METHODS: Stereoview optic nerve photographs, visual field examination, intraocular pressure measurements, medical and ocular history, and a screening and full threshold frequency-doubling perimetry examination were performed in a prospective study of consecutive subjects, Inclusion criteria included age of 45 years or older, absence of ocular disease other than glaucoma, cataract, or mild drusen, and Snellen visual acuity of 20/60 or better. A total of 125 eyes in 102 glaucoma subjects and 95 eyes of 95 normal subjects were included. Each eye was classified as "normal," "glaucoma," Or "uncertain" by each of three ophthalmologists on the basis of all available clinical information with the exception of frequency-doubling perimetry results. Those in the glaucoma group were subclassified as having early (n = 51), moderate (n = 42), or severe (n = 32) glaucoma on the basis of automated Humphrey visual field criteria. In the glaucoma group, two eyes from a subject were allowed to be included (23 of 102 subjects) if they differed in level of damage because they were never analyzed within the same statistical analysis. RESULTS: Several diagnostic algorithms were evaluated. Algorithms based on the most depressed single point, pair of adjacent points, and cluster of three points performed nearly identically. For the screening test, if any abnormality was identified, specificity was 95%, whereas sensitivity was 39%, 86%, and 100% for early, moderate, and severe glaucoma, respectively. For the full threshold test, with at least one point depressed to the P < 0.5% level, specificity measured 91%, whereas sensitivity was 35%, 88%, and 100% for early, moderate, and severe glaucoma, respectively, The two global indices, mean deviation and pattern standard deviation, were also evaluated and were generally less accurate. CONCLUSION: Frequency-doubling perimetry, which is rapid and easily administered, is effective at detecting moderate and severe disease and appears well suited for glaucoma screening. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 50 条
  • [31] Impact of cataract on the results of frequency-doubling technology perimetry
    Tanna, AP
    Abraham, C
    Lai, J
    Shen, J
    OPHTHALMOLOGY, 2004, 111 (08) : 1504 - 1507
  • [32] Frequency-doubling perimetry in young children - Author reply
    Blumenthal, EZ
    Haddad, A
    Horani, A
    Anteby, I
    OPHTHALMOLOGY, 2005, 112 (01) : 169 - 170
  • [33] Relationship Between Retinal Nerve Fiber Layer Parameters and Frequency-Doubling Perimetry in Glaucoma Patients
    Fuertes, M. I.
    Ferreras, A.
    Pablo, L. E.
    Larrosa, J. M.
    Polo, V.
    Garcia-Martin, E.
    Calvo, P.
    Idoipe, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [34] Is reading disability likely to interfere with glaucoma screening of adults using frequency-doubling technology perimetry?
    Edwards, JD
    De Leon-Ortega, J
    Bearden, WH
    Rumble, ME
    Girkin, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) : 816 - 820
  • [35] Fast test procedures for frequency-doubling perimetry.
    Turpin, AH
    Johnson, CA
    Vingrys, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S293 - S293
  • [36] Long-term fluctuation of standard automatic perimetry, pulsar Perimetry and frequency-doubling technology in early glaucoma diagnosis
    Gonzalez-Hernandez, M.
    de la Rosa, M. Gonzalez
    de la Vega, R. Rodriguez
    Hernandez-Vidal, A.
    OPHTHALMIC RESEARCH, 2007, 39 (06) : 338 - 343
  • [37] Diagnostic Accuracy of Frequency-Doubling Technology and the Moorfields Motion Displacement Test for Glaucoma
    Richardson, Quintin R.
    Kumar, Rajesh S.
    Ramgopal, Balu
    V. Rackenchath, Mahalakshmi
    Devi, A. V. Sathi
    Mannil, Suria S.
    Nagaraj, Sriharsha
    Moe, Caitlin A.
    Wittberg, Dionna M.
    O'Brien, Kieran S.
    Oatts, Julius T.
    Stamper, Robert L.
    Keenan, Jeremy D.
    OPHTHALMOLOGY GLAUCOMA, 2023, 6 (03): : 239 - 246
  • [38] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [39] Performance of frequency doubling perimetry in screening for glaucoma
    Weih, L
    Sakellariou, A
    Rait, J
    McCarty, C
    Taylor, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S477 - S477
  • [40] Structure-Function Relationship between Frequency-Doubling Technology Perimetry and Optical Coherence Tomography in Glaucoma
    Fuertes-Lazaro, Isabel
    Sanchez-Cano, Ana
    Ferreras, Antonio
    Ferrandez, Blanca
    Calvo, Pilar
    Abadia, Beatriz
    Otin, Sofia
    Pablo, Luis E.
    OPHTHALMOLOGICA, 2014, 232 (04) : 230 - 238