A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty

被引:4
|
作者
Kawaguchi, Kohei [1 ]
Inui, Hiroshi [1 ]
Yamagami, Ryota [1 ]
Kenichi, Kono [1 ]
Sameshima, Shin [1 ]
Kage, Tomofumi [1 ]
Taketomi, Shuji [1 ]
Tanaka, Sakae [1 ]
机构
[1] Tokyo Univ Hosp, Dept Orthopaed, Tokyo, Japan
来源
KNEE | 2021年 / 29卷
关键词
Tibial component rotation; Range of motion technique; Total knee arthroplasty; Navigation system; Akagi's line; REPLACEMENT; KINEMATICS;
D O I
10.1016/j.knee.2021.02.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We evaluated the effectiveness of our new technique "Range of motion-anatomical (ROM-A) technique" which is the combination of the self-positioning technique "Range of motion (ROM) technique" and the anatomical landmarks technique in determining the tibial component (TC) rotation alignment in total knee arthroplasty (TKA) using a navigation system. Methods: This retrospective study included 103 knees who underwent TKA. The ROM-A technique was consisted of two steps. First, the TC was set and marked by the ROM technique in knee extension. Second, the TC was set according to the marking in the knee flexion and the component rotational angle relative to the anatomical tibial anteroposterior (AP) axis was adjusted between 0 degrees and 10 degrees external rotation using the navigation system. The rotational angle of TC relative to the anatomical AP axis was measured using postoperative computed tomography. Moreover, the hypothetical rotational angle of the TC in the ROM technique was calculated only from the intraoperative difference between the two techniques. Results: The actual rotational angle by the ROM-A technique was externally rotated 3.0 degrees, and the rotational outlier occurred in 3.0%. A significant difference in outlier rate was observed between the two techniques (p = 0.03). The hypothetical rotational angle of TC determined by the ROM technique (the first step only in the ROM-A technique) was externally rotated 4.6 degrees and the TC rotational outlier (difference to AP axis: >10 degrees) occurred in 11.7%. Conclusion: Using the ROM-A technique, the TC was finally fixed in almost all targeted rotational positions, and this technique could reduce the anatomical rotational outlier compared with the ROM technique. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [41] Femoral rotational alignment using the tibial shaft axis in total knee arthroplasty
    Stiehl, JB
    Cherveny, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (331) : 47 - 55
  • [42] Component rotational alignment in unexplained painful primary total knee arthroplasty
    Bell, Stuart W.
    Young, Peter
    Drury, Colin
    Smith, Jules
    Anthony, Iain
    Jones, Bryn
    Blyth, Mark
    McLean, Angus
    KNEE, 2014, 21 (01): : 272 - 277
  • [43] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Florian Geiger
    Dominik Parsch
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 267 - 270
  • [44] A clinical study of the rotational alignment of the femoral component in total knee arthroplasty
    Ding, Liangjia
    Liu, Xiaomin
    Liu, Changlu
    Liu, Yingli
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2077 - 2081
  • [45] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Geiger, Florian
    Parsch, Dominik
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (03) : 267 - 270
  • [46] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Kim, Joong Il
    Jang, Jak
    Lee, Ki Woong
    Han, Hyuk Soo
    Lee, Sahnghoon
    Lee, Myung Chul
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [47] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Joong Il Kim
    Jak Jang
    Ki Woong Lee
    Hyuk Soo Han
    Sahnghoon Lee
    Myung Chul Lee
    BMC Musculoskeletal Disorders, 18
  • [48] Change in tibiofemoral rotational alignment during total knee arthroplasty
    Watanabe, Satoshi
    Sato, Takashi
    Omori, Go
    Koga, Yoshio
    Endo, Naoto
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (04) : 571 - 578
  • [49] Knee alignment in the transverse plane during weight-bearing activity and its implication for the tibial rotational alignment in total knee arthroplasty
    Yin, Li
    Chen, Kaining
    Guo, Lin
    Cheng, Liangjun
    Wang, Fuyou
    Yang, Liu
    CLINICAL BIOMECHANICS, 2015, 30 (06) : 565 - 571
  • [50] The Effect of Coronal Alignment on Tibial Component Migration Following Total Knee Arthroplasty
    van Hamersveld, Koen T.
    Marang-van de Mheen, Perla J.
    Nelissen, Rob G. H. H.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (13): : 1203 - 1212