Numerical Simulations of Construction of Shield Tunnel with Small Clearance to Adjacent Tunnel without and with Isolation Pile Reinforcement

被引:49
|
作者
Lv, Jianbing [1 ]
Li, Xulong [1 ]
Li, Zhanrong [2 ]
Fu, Helin [3 ]
机构
[1] Guangdong Univ Technol, Coll Civil & Transportat Engn, Guangzhou 510000, Guangdong, Peoples R China
[2] China Tunnel Construct Co Ltd, Guangzhou 510000, Guangdong, Peoples R China
[3] Cent S Univ, Sch Civil Engn, Changsha 410012, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Small spacing; Shield construction; Bored pile reinforcement; Numerical simulation; Settlement; Deformation monitoring; DISTANCE;
D O I
10.1007/s12205-020-1167-y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the process of building subways in many cities, the technology of shield tunneling has become more widely used. In large cities, it is inevitable for the tunnels to pass through the foundations of buildings or between deep piles of bridges. Due to the many restrictions on urban space in China, the clearance between two tunnels has also become smaller. Hence, it is an urgent technical problem to resolve the mutual influence of the close construction of two tunnels using shield technology. In this study, the shield construction project of two tunnels with a small clearance of 2.6 m has been analyzed. The project is between Tongdewei Station and Shangbu Station in the northern extension section of the Guangzhou Metro Line 8. The main parameters used in the analyses are the tunnel lining deformation and the ground settlement. The construction without and with the isolation pile reinforcement have been simulated numerically. The simulation results have been compared with the on-site monitoring data. Based on the comparison, it shows that with the reinforcement, the tunnel lining deformation and the ground settlement can be reduced significantly. The effect of subway shield construction on the construction of the first subway tunnel will significantly reduce. The deformation of the shield excavation net width and the mutual influence can also be greatly reduced. The findings from this study can be used as technical foundation and reference for the construction of similar projects, i.e. shield tunnel construction with a small clearance between tunnels.
引用
收藏
页码:295 / 309
页数:15
相关论文
共 50 条
  • [1] Numerical Simulations of Construction of Shield Tunnel with Small Clearance to Adjacent Tunnel without and with Isolation Pile Reinforcement
    Jianbing Lv
    Xulong Li
    Zhanrong Li
    Helin Fu
    KSCE Journal of Civil Engineering, 2020, 24 : 295 - 309
  • [2] Deformation and Reinforcement of the Existing Tunnel Affected by New Shield Tunnel Construction with Small Clearance
    Zhang, Junchao
    Yu, Jiacheng
    Li, Cunjun
    Liu, Yizhou
    Tian, Longgang
    He, Yonglin
    Zhang, Qi
    BUILDINGS, 2025, 15 (02)
  • [3] Numerical analysis of influence of pile foundation construction on adjacent metro tunnel
    Ding Z.
    Zhang X.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (02): : 390 - 399
  • [4] Reinforcement Effects of Isolation Piles on the Adjacent Existing Tunnel in Building Construction
    Yao, Aijun
    Lu, Jian
    Guo, Yanfei
    Zhang, Jiantao
    Guo, Haifeng
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2019, 2019
  • [5] Numberical Analysis in the Deformation of Adjacent Buildings and Underground Pile caused by Tunnel Shield Construction
    Zhang, Jianxin
    Wu, Tingliang
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 1444 - 1449
  • [6] Numerical simulation of heat-supplying tunnel adjacent to subway shield tunnel
    Li, C. H.
    He, S. H.
    Chen, X. D.
    ROCK MECHANICS: ACHIEVEMENTS AND AMBITIONS, 2012, : 297 - 300
  • [7] Numerical analysis of Hefei metro shield tunnel construction crossing pile foundation of building
    Ding, Kewei
    Man, Dawei
    CIVIL ENGINEERING AND URBAN PLANNING III, 2014, : 245 - 248
  • [8] Numerical investigation of tunnel deformation due to adjacent loaded pile and pile-soil-tunnel interaction
    Lueprasert, Prateep
    Jongpradist, Pornkasem
    Jongpradist, Pattaramon
    Suwansawat, Suchatvee
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2017, 70 : 166 - 181
  • [9] Three-dimensional numerical analysis of effect of tunnel construction on adjacent pile foundation
    Department of Geotechnical Engineering, Tongji University, Shanghai 200092, China
    不详
    Yanshilixue Yu Gongcheng Xuebao, SUPPL. 1 (2601-2607):
  • [10] Mechanical behaviours of a shield tunnel adjacent to existing viaduct pile foundations
    Yuan, Haiping
    Wang, Bin
    Zhu, Dayong
    Chen, Shuimei
    Han, Zhiyong
    Yao, Huayan
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2014, 33 (07): : 1457 - 1464