Application of non-specific gas sensors for detecting odour abatement process failure

被引:0
|
作者
Stuetz, RM [1 ]
Bourgeois, W [1 ]
机构
[1] Univ New S Wales, Sch Civil & Environm Engn, Sydney, NSW 2052, Australia
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An array of non-specific gas sensors were used to continuously monitor for changes in the compositions of an odorous emission. Wastewater was sparged to generate a headspace gas which was subsequently transferred to an online flowcell for periodic anatysis by an array of conducting polymer sensors. Response patterns between the different sensors were used to detect for the presence of changes in the composition of the headspace gas. In order to stimulate process failure, the wastewater was periodically spiked with known concentration of different chemicals to promote abnormalities in the wastewater headspace gas. A model was developed for the detection and identification of sudden changes in the sensor responses and was successfully tested using large datasets acquired over several months. The results demonstrated that a chemical sensor array can act as an online monitoring system for the detection of odour treatment process failures and could be more widely accepted for monitoring the treatment performance of odour abatement systems.
引用
收藏
页码:463 / 471
页数:9
相关论文
共 50 条
  • [31] Application of a combined methodology with tecar therapy for non-specific pain in the lumbosacral region
    Georgieva, Dilyana
    Avramova, Margarita
    Mitova, Stamenka
    JOURNAL OF IMAB, 2022, 22 : 108 - 110
  • [32] DEVELOPMENT OF FAULT SPECIFIC SOFT SENSORS WITH APPLICATION TO GAS TURBINE DIAGNOSIS
    Scheianu, Dorin
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 1, 2012, : 895 - 902
  • [33] Ventricular arrhythmias in patients with congestive heart failure: Non-specific predictors of sudden death
    Teerlink, JR
    Jalaluddin, M
    Anderson, SA
    Kukin, ML
    Eichhorn, EJ
    Massie, BM
    CIRCULATION, 1997, 96 (08) : 2186 - 2186
  • [34] Non-specific conducting polymer-based array capable of monitoring odour emissions from a biofiltration system in a piggery building
    Sohn, Jae Ho
    Dunlop, Mark
    Hudson, Neale
    Kim, Tae Il
    Yoo, Yong Hee
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 135 (02): : 455 - 464
  • [35] Investigation of non-specific signals in nanoporous flow-through and flow-over based sensors
    Kumar, Neeraj
    Froner, Elena
    Guider, Romain
    Scarpa, Marina
    Bettotti, Paolo
    ANALYST, 2014, 139 (06) : 1345 - 1349
  • [36] Application of aspartic acid as a non-specific binding inhibitor in the enrichment of phosphopeptides with titanium dioxide
    Chi Ming
    Bi Wei
    Lu Zhuang
    Song Lina
    Jia Wei
    Zhang Yangjun
    Qian Xiaohong
    Cai Yun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (02) : 152 - 157
  • [37] CORTICOTROPHIN RELEASE IN MICE - FAILURE OF PETOBARBITAL-MORPHINE TO BLOCK EFFECT OF NON-SPECIFIC STRESS
    RERUP, C
    ACTA ENDOCRINOLOGICA, 1964, 46 (03): : 387 - &
  • [38] Non-specific retention characteristics of dissolved β-cyclodextrin derivatives in open tubular column gas chromatography
    Kiridena, W
    Poole, CF
    Nawas, MI
    Koziol, WW
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (12-13): : 1111 - 1118
  • [39] Characterization of an Algerian diatomite by inverse gas chromatography: Specific and non-specific contribution and Lewis acid-base parameters
    Daoui, Hanifa
    Boutoumi, Hocine
    Bouhamidi, Yasmine
    Boucherit, Ahmed
    Zouikri, Mohamed
    INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 2018, 23 (05) : 463 - 473
  • [40] EVALUATING THE CAPACITY OF HUMAN SERUM ALBUMIN TO REDUCE NON-SPECIFIC BINDING OF MELOXICAM IN THE ULTRAFILTRATION PROCESS
    Imre, Silvia
    Toma, Camelia-Maria
    Vari, Camil-Eugen
    FARMACIA, 2021, 69 (06) : 1066 - 1072