Estimation of photoneutron yield in linear accelerator with different collimation systems by Geant4 and MCNPX simulation codes

被引:10
|
作者
Kim, Yoon Sang [1 ]
Khazaei, Zeinab [2 ]
Ko, Junho [1 ]
Afarideh, Hossein [2 ]
Ghergherehchi, Mitra [3 ]
机构
[1] Korea Univ Technol & Educ, Dept Comp Sci & Engn, Cheonan, England
[2] Amirkabir Univ Technol, Dept Energy Engn & Phys, Tehran, Iran
[3] Sungkyunkwan Univ, Sch Elect & Elect Engn, Coll Informat & Commun Engn, Suwon, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 07期
关键词
Monte Carlo simulation code; linear accelerator; collimator; photoneutron convertor; neutron yield; MONTE-CARLO-SIMULATION; NEUTRON; TARGETS; SPECTRA; BERYLLIUM; TUNGSTEN; COPPER;
D O I
10.1088/0031-9155/61/7/2762
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At present, the bremsstrahlung photon beams produced by linear accelerators are the most commonly employed method of radiotherapy for tumor treatments. A photoneutron source based on three different energies (6, 10 and 15 MeV) of a linac electron beam was designed by means of Geant4 and Monte Carlo N-Particle eXtended (MCNPX) simulation codes. To obtain maximum neutron yield, two arrangements for the photo neutron convertor were studied: (a) without a collimator, and (b) placement of the convertor after the collimator. The maximum photon intensities in tungsten were 0.73, 1.24 and 2.07 photon/e at 6, 10 and 15 MeV, respectively. There was no considerable increase in the photon fluence spectra from 6 to 15 MeV at the optimum thickness between 0.8 mm and 2 mm of tungsten. The optimum dimensions of the collimator were determined to be a length of 140 mm with an aperture of 5 mm x 70 mm for iron in a slit shape. According to the neutron yield, the best thickness obtained for the studied materials was 30 mm. The number of neutrons generated in BeO achieved the maximum value at 6 MeV, unlike that in Be, where the highest number of neutrons was observed at 15 MeV. Statistical uncertainty in all simulations was less than 0.3% and 0.05% for MCNPX and the standard electromagnetic (EM) physics packages of Geant4, respectively. Differences among spectra in various regions are due to various cross-section and stopping power data and different simulations of the physics processes.
引用
收藏
页码:2762 / 2779
页数:18
相关论文
共 50 条
  • [41] Photo-neutron production of medical linear accelerator Elekta, precise model: A study with the Geant4 MC toolkit
    Farrag, Emad A. M.
    Wadi-Ramahi, Shada
    Hamad, Morad Kh.
    ANNALS OF NUCLEAR ENERGY, 2023, 194
  • [42] Development and Validation of a 0.35T MR-Guided Linear Accelerator Monte Carlo Model in GEANT4
    Khan, A.
    Simiele, E.
    Yadav, P.
    MEDICAL PHYSICS, 2020, 47 (06) : E741 - E741
  • [43] An experimental and GEANT4 simulation study on design of a broad energy-range magnetic spectrograph for laser plasma accelerator
    Mishra, S.
    Hazra, D.
    Moorti, A.
    Chakera, J. A.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (01):
  • [44] Investigation of the use of external aluminium targets for portal imaging in a medical accelerator using Geant4 Monte Carlo simulation
    Kim, Hyungdong
    Kim, Byungyong
    Baek, Jonggeun
    Oh, Youngkee
    Yun, Sangmo
    Jang, Hyunsoo
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):
  • [45] Simulation of Leksell Gamma Knife-4C System with Different Phantoms Using PHITS and Geant4
    Hung, B. T.
    Duong, T. T.
    Ha, B. N.
    ATOM INDONESIA, 2023, 49 (01) : 13 - 20
  • [46] A novel embedded spherical semiconductor neutron detector efficiency estimation using GEANT4 simulation methodology
    Nayak, Avinash
    Kumar, Vikas
    Parida, Manoj Kumar
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (03)
  • [47] CPU time optimization and precise adjustment of the Geant4 physics parameters for a VARIAN 2100 C/D gamma radiotherapy linear accelerator simulation using GAMOS
    Arce, Pedro
    Ignacio Lagares, Juan
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [48] Optimization of Target Design and Dose Rates for FLASH-RT of An 18 MV Medical Linear Accelerator Model Via GEANT4 Monte Carlo Simulation
    Li, A.
    Kutsaev, S.
    Yu, V.
    Boucher, S.
    Sheng, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E548 - E548
  • [49] An investigation of the simulation response of GEM-based detector for the fast neutrons by employment of GEANT4 & MCNP MC codes
    Ahmad, Farzana
    Zubair, M.
    Thanh-Mai, Vu
    Jamil, M.
    PHYSICA SCRIPTA, 2024, 99 (02)
  • [50] GEANT4 SIMULATION FOR THE ZENITH ANGLE DEPENDENCE OF COSMIC MUON INTENSITIES AT TWO DIFFERENT GEOMAGNETIC LOCATIONS
    Arslan, Halil
    Bektasoglu, Mehmet
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2013, 28 (16):