Extraction of mechanical properties of articular cartilage from osmotic swelling behavior monitored using high frequency ultrasound

被引:16
|
作者
Wang, Q. [1 ]
Zheng, Y. P.
Niu, H. J.
Mak, A. F. T.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Hong Kong, Hong Kong, Peoples R China
[2] Beihang Univ, Dept Biomed Engn, Beijing, Peoples R China
关键词
articular cartilage; ultrasound; elastography; biomechanics; triphasic theory; proteoglycan; fixed charge density; osmotic loading; osteoarthritis;
D O I
10.1115/1.2720919
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Articular cartilage is a biological weight-bearing tissue covering the bony ends of articulating joints. Negatively charged proteoglycan (PG) in articular cartilage is one of the main factors that govern its compressive mechanical behavior and swelling phenomenon. PG is nonuniformly distributed throughout the depth direction, and its amount or distribution may change in the degenerated articular cartilage such as osteoarthritis. In this paper we used a 50 MHz ultrasound system to study the depth-dependent strain of articular cartilage under the osmotic loading induced by the decrease of the bathing saline concentration. The swelling-induced strains under the osmotic loading were used to determine the layered material properties of articular cartilage based on a triphasic model of the free-swelling. Fourteen cylindrical cartilage-bone samples prepared from fresh normal bovine patellae were tested in situ in this study. A layered triphasic model was proposed to describe the depth distribution of the swelling strain for the cartilage and to determine its aggregate modulus H-a at two different layers, within which H-a was assumed to be linearly dependent on the depth. The results showed that H-a was 3.0 +/- 3.2, 7.0 +/- 7.4, 24.5 +/- 11.1 MPa at the cartilage surface, layer interface, and deep region, respectively. They are significantly different (p < 0.01). The layer interface located at 70% +/- 20% Of the overall thickness from the uncalcified-calcified cartilage interface. Parametric analysis demonstrated that the depth-dependent distribution of the water,fraction had a significant effect on the modeling results but not the fixed charge density This study showed that high-frequency ultrasound measurement together with triphasic modeling is practical for quantifying the layered mechanical properties of articular cartilage nondestructively and has the potential for providing useful information for the detection of the early signs of osteoarthritis.
引用
收藏
页码:413 / 422
页数:10
相关论文
共 50 条
  • [31] Localized delivery of compounds into articular cartilage by using high-intensity focused ultrasound
    Heikki J. Nieminen
    Eetu Lampsijärvi
    Gonçalo Barreto
    Mikko A. J. Finnilä
    Ari Salmi
    Anu J. Airaksinen
    Kari K. Eklund
    Simo Saarakkala
    Kenneth P. H. Pritzker
    Edward Hæggström
    Scientific Reports, 9
  • [32] Ultrasound Elastography to Determine the Layered Mechanical Properties of Articular Cartilage and the Importance of Such Structural Characteristics under Load
    McCredie, Alexandra J.
    Stride, Eleanor
    Saffari, Nader
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4262 - 4265
  • [33] OSCILLATORY COMPRESSIONAL BEHAVIOR OF ARTICULAR-CARTILAGE AND ITS ASSOCIATED ELECTRO-MECHANICAL PROPERTIES
    LEE, RC
    FRANK, EH
    GRODZINSKY, AJ
    ROYLANCE, DK
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (04): : 280 - 292
  • [34] Comparison of articular cartilage images assessed by high-frequency ultrasound microscope and scanning acoustic microscope
    Yoshihiro Hagiwara
    Yoshifumi Saijo
    Akira Ando
    Yoshito Onoda
    Hideaki Suda
    Eiichi Chimoto
    Kouki Hatori
    Eiji Itoi
    International Orthopaedics, 2012, 36 : 185 - 190
  • [35] Comparison of articular cartilage images assessed by high-frequency ultrasound microscope and scanning acoustic microscope
    Hagiwara, Yoshihiro
    Saijo, Yoshifumi
    Ando, Akira
    Onoda, Yoshito
    Suda, Hideaki
    Chimoto, Eiichi
    Hatori, Kouki
    Itoi, Eiji
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (01) : 185 - 190
  • [36] COMPARISON OF NORMAL ARTICULAR CARTILAGE IMAGES ASSESSED BY HIGH FREQUENCY ULTRASOUND MICROSCOPE AND SCANNING ACOUSTIC MICROSCOPE
    Hagiwara, Y.
    Saijo, Y.
    Ando, A.
    Onoda, Y.
    Suda, H.
    Chimoto, E.
    Hatori, K.
    Itoi, E.
    OSTEOARTHRITIS AND CARTILAGE, 2011, 19 : S183 - S183
  • [37] Quantitative assessment of arthritic cartilage using high-frequency ultrasound
    Saïed, A
    Bossy, E
    Watrin, A
    Pellaumail, B
    Loeuille, D
    Laugier, P
    Netter, P
    Berger, G
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1375 - 1378
  • [38] A Guide for Using Mechanical Stimulation to Enhance Tissue-Engineered Articular Cartilage Properties
    Salinas, Evelia Y.
    Hu, Jerry C.
    Athanasiou, Kyriacos
    TISSUE ENGINEERING PART B-REVIEWS, 2018, 24 (05) : 345 - 358
  • [39] METHODS OF MEASURING MECHANICAL PROPERTIES OF PLASTICS WITH HIGH FREQUENCY ULTRASOUND
    MCSKIMIN, HJ
    CHAMBERS, RP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1964, SU11 (02): : 109 - &
  • [40] Determining Tension–Compression Nonlinear Mechanical Properties of Articular Cartilage from Indentation Testing
    Xingyu Chen
    Yilu Zhou
    Liyun Wang
    Michael H. Santare
    Leo Q. Wan
    X. Lucas Lu
    Annals of Biomedical Engineering, 2016, 44 : 1148 - 1158