Retention of arsenate using genetically modified coryneform bacteria and determination of arsenic in solid samples by ICP-MS

被引:19
|
作者
Villadangos, A. F. [2 ]
Ordonez, E. [2 ]
Munoz, M. I. [1 ]
Pastrana, I. M. [1 ]
Fiuza, M. [2 ]
Gil, J. A. [2 ]
Mateos, L. M. [2 ]
Aller, A. J. [1 ]
机构
[1] Univ Leon, Dept Appl Chem & Phys, Area Analyt Chem, E-24071 Leon, Spain
[2] Univ Leon, Area Microbiol, Dept Mol Biol, E-24071 Leon, Spain
关键词
Arsenate; Corynebacterium glutamicum; Genetically modified bacteria; Mathematical modeling; ICP-MS; ATOMIC-ABSORPTION-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; PLASMA-MASS-SPECTROMETRY; CORYNEBACTERIUM-GLUTAMICUM; ESCHERICHIA-COLI; PSEUDOMONAS-PUTIDA; TRACE-ELEMENTS; SPECIATION; CELLS; PRECONCENTRATION;
D O I
10.1016/j.talanta.2009.09.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the retention of arsenate [As(V)l combining time-controlled solid-phase extraction with living bacterial biomass is presented. As(V) retention was carried out by exposing the extractant, consisting of a living double-mutant of Corynebacterium glutamicum strain ArsC1-C2, to the sample for a retention time of 1-7 min, before the arsenic distribution equilibrium between the sample solution and the extractant was established. The amount of As(V) retained in the biomass was measured by inductively coupled plasma-mass spectrometry (ICP-MS) after the sample had been treated with nitric acid. A theoretical model of the retention process was developed to describe the experimental retention-time profiles obtained with the bacterial cells. This relationship provided a feasible quantification of the retention process before steady-state was reached, providing that the agitation conditions and the retention time had been controlled. An analytical procedure for the retention/quantification of As(V) was then developed; the detection limit was 0.1 ng As(V) mL(-1) and the relative standard deviation 2.4-3.0%. The maximum effective retention capacity for As(V) was about 12.5 mg As (g biomass)(-1). The developed procedure was applied to the determination of total arsenic in coal fly ash, using a sample that had undergone oxidative pre-treatment. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1421 / 1427
页数:7
相关论文
共 50 条
  • [21] Determination of Se in blood and tissue of animal samples by normal ICP-MS and ICP-MS with Octupole Reaction System
    Ying-feng, Wang
    Cui-mei, Liu
    shao-qing, Liu
    Yan-zhi, Shi
    Yu-hong, Chen
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (09) : 2173 - 2176
  • [22] Electrothermal vaporization using a tungsten filament followed by ICP-MS for the determination of arsenic in microsamples
    Tanaka, T
    Furuhashi, K
    Matsuo, D
    Hiraide, M
    BUNSEKI KAGAKU, 2000, 49 (02) : 125 - 127
  • [23] Determination of five arsenic species in aqueous samples by HPLC coupled with a hexapole collision cell ICP-MS
    Xie, QL
    Kerrich, R
    Irving, E
    Liber, K
    Abou-Shakra, F
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) : 1037 - 1041
  • [24] On-line chloride interference removal for arsenic determination in waste water and urine by ICP-MS using a modified capillary
    Malik, AK
    Gómez, M
    Cámara, C
    Riepe, HG
    Bettmer, J
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2002, 82 (11-12) : 795 - 804
  • [26] Determination of five arsenic species in aqueous samples by HPLC coupled with a hexapole collision cell ICP-MS
    Xie, Q. (xieq@duke.usask.ca), 1600, Royal Society of Chemistry (17):
  • [27] DETERMINATION OF INORGANIC AND ORGANIC ARSENIC COMPOUNDS IN URINE USING ION CHROMATOGRAPHY WITH ICP-MS
    INOUE, Y
    KAWABATA, K
    TAKAHASHI, H
    ENDO, G
    BUNSEKI KAGAKU, 1995, 44 (03) : 203 - 208
  • [28] Determination of boron and lithium in ferroelectric samples by ICP-OES and ICP-MS
    Vuollo, Pekka
    Honkamo, Johanna
    Niemela, Matti
    Peramaki, Paavo
    Jantunen, Heli
    MICROCHIMICA ACTA, 2009, 164 (1-2) : 217 - 224
  • [29] Determination of boron and lithium in ferroelectric samples by ICP-OES and ICP-MS
    Pekka Vuollo
    Johanna Honkamo
    Matti Niemelä
    Paavo Perämäki
    Heli Jantunen
    Microchimica Acta, 2009, 164 : 217 - 224
  • [30] Determination of lead isotopes ratio in rock samples by ICP-MS
    Zheng, Pei-Xi
    Zhou, Yan
    Wang, Tie-Fu
    Liu, Li
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1522 - A1522