Retention of arsenate using genetically modified coryneform bacteria and determination of arsenic in solid samples by ICP-MS

被引:19
|
作者
Villadangos, A. F. [2 ]
Ordonez, E. [2 ]
Munoz, M. I. [1 ]
Pastrana, I. M. [1 ]
Fiuza, M. [2 ]
Gil, J. A. [2 ]
Mateos, L. M. [2 ]
Aller, A. J. [1 ]
机构
[1] Univ Leon, Dept Appl Chem & Phys, Area Analyt Chem, E-24071 Leon, Spain
[2] Univ Leon, Area Microbiol, Dept Mol Biol, E-24071 Leon, Spain
关键词
Arsenate; Corynebacterium glutamicum; Genetically modified bacteria; Mathematical modeling; ICP-MS; ATOMIC-ABSORPTION-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; PLASMA-MASS-SPECTROMETRY; CORYNEBACTERIUM-GLUTAMICUM; ESCHERICHIA-COLI; PSEUDOMONAS-PUTIDA; TRACE-ELEMENTS; SPECIATION; CELLS; PRECONCENTRATION;
D O I
10.1016/j.talanta.2009.09.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the retention of arsenate [As(V)l combining time-controlled solid-phase extraction with living bacterial biomass is presented. As(V) retention was carried out by exposing the extractant, consisting of a living double-mutant of Corynebacterium glutamicum strain ArsC1-C2, to the sample for a retention time of 1-7 min, before the arsenic distribution equilibrium between the sample solution and the extractant was established. The amount of As(V) retained in the biomass was measured by inductively coupled plasma-mass spectrometry (ICP-MS) after the sample had been treated with nitric acid. A theoretical model of the retention process was developed to describe the experimental retention-time profiles obtained with the bacterial cells. This relationship provided a feasible quantification of the retention process before steady-state was reached, providing that the agitation conditions and the retention time had been controlled. An analytical procedure for the retention/quantification of As(V) was then developed; the detection limit was 0.1 ng As(V) mL(-1) and the relative standard deviation 2.4-3.0%. The maximum effective retention capacity for As(V) was about 12.5 mg As (g biomass)(-1). The developed procedure was applied to the determination of total arsenic in coal fly ash, using a sample that had undergone oxidative pre-treatment. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1421 / 1427
页数:7
相关论文
共 50 条
  • [1] Application of ICP-MS to arsenic determination in solid samples containing silica
    Diaz-Somoano, M
    Martinez-Tarazona, MR
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1439 - 1442
  • [2] Accurate determination of arsenic and selenium in plant food samples by using ICP-MS/MS
    Hu, Xianqiao
    Cao, Zhaoyun
    Sun, Weihua
    Yang, Huan
    Xu, Ping
    Zhu, Zhiwei
    ANALYTICAL METHODS, 2016, 8 (32) : 6150 - 6157
  • [3] Determination of arsenic by ICP-MS after retention on thoria nanoparticles
    Pereira, F. J.
    Vazquez, M. D.
    Deban, L.
    Aller, A. J.
    ANALYTICAL METHODS, 2015, 7 (02) : 598 - 606
  • [4] Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS
    Verola Mataveli, Lidiane Raquel
    Buzzo, Marcia Liane
    de Arauz, Luciana Juncioni
    Henriques Carvalho, Maria de Fatima
    Kumagai Arakaki, Edna Emy
    Matsuzaki, Richard
    Tiglea, Paulo
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [5] Determination of total arsenic concentration in clinical samples for epidemiological studies using ICP-MS
    Sekhar, C
    Chary, NS
    Kamala, CT
    Anupama, M
    Reddy, MRP
    ATOMIC SPECTROSCOPY, 2002, 23 (05) : 170 - 175
  • [6] Accurate Determination of Arsenic and Selenium in Environmental Samples using the Thermo Scientific iCAP TQ ICP-MS
    Manecki, Marcus
    Lofthouse, Simon
    Boening, Philipp
    Ducos, Shona McSheehy
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 5 (18): : 62 - 67
  • [7] Direct Determination of Arsenic and Chromium in Seawater Samples Using On-Line Dilution and ICP-MS Analysis
    Carmen Barciela-Alonso, Maria
    Castrelo Otero, Marta
    Dominguez Gonzalez, Maria Raquel
    Pena-Vazquez, Elena
    Bermejo-Barrera, Pilar
    ATOMIC SPECTROSCOPY, 2016, 37 (03) : 91 - 95
  • [8] DETERMINATION OF ARSENIC IN NATURAL AND TAP WATERS BY ICP-MS
    TAKAKU, Y
    MASUDA, K
    KOBAYASHI, T
    SHIMAMURA, T
    BUNSEKI KAGAKU, 1994, 43 (11) : 897 - 903
  • [9] Quantitative Determination of Bromine and Iodine in Food Samples Using ICP-MS
    Thi Kim Dzung Nguyen
    Rainer Ludwig
    Analytical Sciences, 2014, 30 : 1089 - 1092
  • [10] Quantitative Determination of Bromine and Iodine in Food Samples Using ICP-MS
    Thi Kim Dzung Nguyen
    Ludwig, Rainer
    ANALYTICAL SCIENCES, 2014, 30 (11) : 1089 - 1092