Study on the voltammetric behavior of metronidazole and its determination at a Co/GC modified electrode

被引:1
|
作者
Zhi, Y [1 ]
Hu, JB [1 ]
Wu, ZD [1 ]
Li, QL [1 ]
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
关键词
ion implantation; modified electrode; metronidazole; linear sweep voltammetry;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In 0.1mol/LKCl+0.02mol/LHCl solution pH=1.66,the electrochemical behaviour of metronidazole has been studied by linear-sweep voltammetry and cyclic voltammertry at a Co/Glassy Carbon (GC) ion implantation modified electrode. The experiments showed that the electrode had good stability and reproducibility. The peak height was proportional to the concentration of metronidazole over the range of 4.0 x 10(-7) to 1.0 x 10(-4) mol/L and the detection limit was 2.0 x 10(-7) mol/L. This method has been used for the direct determination of metronidazole in tablets. Recoveries were in the range from 94.0% to 104.2%. The reduction of metronidazole at a Co/GC electrode was an irreversible process.
引用
收藏
页码:429 / 437
页数:9
相关论文
共 50 条
  • [41] Electrochemical behavior and voltammetric determination of pyrazinamide using a poly-histidine modified electrode
    Bergamini, Marcio F.
    Santos, Daniela P.
    Zanoni, Maria Valnice B.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 690 : 47 - 52
  • [42] Voltammetric behavior and determination of estrogens at carbamylcholine modified paraffin-impregnated graphite electrode
    Jin, GP
    Lin, XQ
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3556 - 3562
  • [43] Electrochemical behavior and voltammetric determination of metol using a multiwall carbon nanotubes modified electrode
    Li, J
    Wang, Y
    Liu, Z
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2006, 42 (01) : 27 - 30
  • [44] Electrochemical behavior of hemoglobin at a lipid-lauric acid modified GC electrode and its application to the determination of proteins
    Jin, SZ
    Wang, T
    Zhang, CX
    Shen, HX
    ACTA CHIMICA SINICA, 2002, 60 (07) : 1269 - 1273
  • [45] Voltammetric behavior of dicynonum at poly (4-aminopyridine) film modified electrode and its determination by adsorptive stripping voltammetry
    Wang, ZH
    Zhang, D
    Zhang, Y
    Zhou, SP
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (01) : 83 - 86
  • [46] Studies on the electrochemical behavior of cytochrome c and its interaction with DNA at a Co/GC ion implantation modified electrode
    Sun, ZJ
    Hu, JB
    Lu, YQ
    Li, QL
    ANALYST, 2003, 128 (07) : 930 - 934
  • [47] Voltammetric Determination of Guaifenesin on a MWCNT Modified Pt Electrode
    Jos, Theresa
    Lonappan, Laina
    Rasheed, Zafna
    Vikraman, Anuja Elevathoor
    Kumarz, Krishnapillai Girish
    ECS ELECTROCHEMISTRY LETTERS, 2014, 3 (12) : B23 - B25
  • [48] Voltammetric determination of nitrendipine on composite film modified electrode
    Yingliang Wei
    Lan Zhang
    Luping Zhang
    Chen Shao
    Chao Li
    Journal of Analytical Chemistry, 2011, 66 : 969 - 973
  • [49] Differential Pulse Stripping Voltammetric Determination of Metronidazole with Graphene-Sodium Dodecyl Sulfate Modified Carbon Paste Electrode
    Zhu, Mingfang
    Ye, Hongqing
    Lai, Mushen
    Ye, Jianshan
    Kuang, Jiemin
    Chen, Yuping
    Wang, Jingyue
    Mei, Qianyi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05): : 4100 - 4114
  • [50] Voltammetric Determination of Nitrendipine on Composite Film Modified Electrode
    Wei, Yingliang
    Zhang, Lan
    Zhang, Luping
    Shao, Chen
    Li, Chao
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (10) : 969 - 973