A PERFORMANCE TEST RESULT OF CHORDAL TYPE FLOWMETER USING HIGH REYNOLDS NUMBER FACILITY IN NMIJ

被引:0
|
作者
Furuichi, Noriyuki [1 ]
Terao, Yoshiya [1 ]
Takamoto, Masaki [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Fluid Flow Div, Tsukuba, Ibaraki, Japan
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, test result of two performance tests of the "Chordal Type" ultrasonic flowmeter made by Cameron inc. using NMIJ's high Reynolds number calibration facility will be presented. This type flowmeter have been introduced to nuclear power plant in USA to MUR uprating. First test is the investigation of the effect of the inner roughness of the upstream pipe. In this test, the difference of the K-factor, which is one of correction factors of a flowmeter, between Ra=1.7 (mm) and 14.2 (mm) is about 0.1%. To obtain the high efficiency of MUR uprating, actual flow calibration is recommended. Second test is the investigation of the relationship between "Profile Factor" and "Velocity Ratio". As a result, the correlation obtained by calibration for many upstream conditions at Re=3.0 x 10(6) can estimate "Profile Factor" at Re=1.4 x 10(7) within +/-0.25% However, the correlation with Reynolds number does not behave as expected by theorem. To obtain the correction factor of flowmeter with high accuracy and reliability, the actual flow calibration under the same Reynolds number at the actual plant condition is the only effective method.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [1] Actual flow calibration of a feedwater flowmeter using a high Reynolds number facility at NMIJ
    Furuichi, Noriyuki
    Terao, Yoshiya
    Takamoto, Masaki
    NUCLEAR ENGINEERING AND DESIGN, 2009, 239 (07) : 1304 - 1313
  • [2] FEASIBILITY OF A FLOWMETER TEST FACILITY TO OPERATE AT HIGH REYNOLDS NUMBERS.
    Neale, L.C.
    Nystrom, J
    Ferron, A.G.
    Hutnicke Listy, 1979,
  • [3] A CALIBRATION OF A FEEDWATER FLOWMETER INSTALLED TO MODEL LOOP OF A NUCLEAR POWER PLANT USING HIGH REYNOLDS NUMBER FACILITY
    Furuichi, Noriyuki
    Terao, Yoshiya
    Takamoto, Masaki
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 145 - 151
  • [4] High Reynolds Number Experimental Facilities for Turbulent Pipe Flow at NMIJ
    Furuichi, Noriyuki
    Terao, Yoshiya
    Tsuji, Yoshiyuki
    PROGRESS IN TURBULENCE VII, 2017, 196 : 95 - 100
  • [5] Comparison of high temperature and high Reynolds number water flows between PTB and NMIJ
    Furuichi, Noriyuki
    Cordova, Leopoldo
    Lederer, Thomas
    Terao, Yoshiya
    FLOW MEASUREMENT AND INSTRUMENTATION, 2016, 52 : 157 - 162
  • [6] An investigation into the effects of the Reynolds number on high-speed trains using a low temperature wind tunnel test facility
    Han Y.
    Chen D.
    Liu S.
    Xu G.
    Han, Yundong (hanley1984@126.com), 2020, Tech Science Press (16): : 1 - 19
  • [7] An Investigation into the Effects of the Reynolds Number on High-Speed Trains Using a Low Temperature Wind Tunnel Test Facility
    Han, Yundong
    Chen, Dawei
    Liu, Shaoqing
    Xu, Gang
    FDMP-FLUID DYNAMICS & MATERIALS PROCESSING, 2020, 16 (01): : 1 - 19
  • [8] Effect of Reynolds number and boundary layer thickness on the performance of V-cone flowmeter using CFD
    Sheikh, Nasiruddin
    Singh, S. N.
    Veeravalli, S. V.
    Hegde, S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2020, 73
  • [9] A new calibration facility for water flowrate at high Reynolds number
    Furuichi, Noriyuki
    Sato, Hiroshi
    Terao, Yoshiya
    Takamoto, Masaki
    FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (01) : 38 - 47
  • [10] Performance test result of superfluid shock tube facility
    Murakami, M
    Nagai, H
    Yang, H
    Takano, N
    Furukawa, T
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 504 - 509