Robust Sensing of Distal Pulse Waveforms on a Modified Weighing Scale for Ubiquitous Pulse Transit Time Measurement

被引:14
|
作者
Carek, Andrew M. [1 ]
Inan, Omer T. [1 ,2 ]
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
基金
美国国家卫生研究院;
关键词
Cardiovascular health; home monitoring; photoplethysmogram; pulse measurements; pulse transit time; BLOOD-PRESSURE; ARTERIAL STIFFNESS; VELOCITY; PHOTOPLETHYSMOGRAPHY; FORCE;
D O I
10.1109/TBCAS.2017.2683801
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of aortic pulse transit time (PTT), the time for the arterial pulse wave to travel from the carotid to the femoral artery, can provide valuable insight into cardiovascular health, specifically regarding arterial stiffness and blood pressure (BP). To measure aortic PTT, both proximal and distal arterial pulse timings are required. Recently, our group has demonstrated that the ballistocardiogram signal measured on a modified weighing scale can provide an unobtrusive, yet accurate, means of obtaining a proximal timing reference; however, there are no convenient, reliablemethods to extract the distal timing from a subject standing on themodified weighing scale. It is common to use a photoplethysmograph (PPG) attached to a toe to measure this distal pulse, but we discovered that this signal is greatly deteriorated as the subject stands on the scale. In this paper, we propose a novel method to measure the distal pulse using a custom reflective PPG array attached to the dorsum side of the foot (D-PPG). A total of 12 subjects of varying skin tones were recruited to assess the preliminary validation of this approach. Pulse measurements using the D-PPG were taken from seated and standing subjects, and the commercially available PPG were measured for facilitating comparison of timing measurements. We show that the D-PPG was the only sensor to retain the high detection rate of feasible timing values. To further test and optimize the system, various factors such as applied pressure, measurement location, and LED/photodiode configuration were tested.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [1] Direct Pulse Transit Time Measurement from an Electronic Weighing Scale
    Gomez-Clapers, Joan
    Casanella, Ramon
    Pallas-Areny, Ramon
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 773 - 776
  • [2] Live Demonstration: Pulse Transit Time Measurement on a Modified Weighing Scale for Cuffless Blood Pressure Estimation
    Carek, Andrew M.
    Conant, Jordan
    Inan, Omer T.
    2016 IEEE SENSORS, 2016,
  • [3] Evaluation of Pulse Transit Time for Different Sensing Methodologies of Arterial Waveforms
    Janjua, Ghalib Muhammad Waqas
    Finlay, Dewar
    Guldenring, Daniel
    Ul Haq, Atta
    McLaughlin, James
    IEEE ACCESS, 2023, 11 : 33928 - 33933
  • [4] Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time
    Martin, Stephanie L. -O.
    Carek, Andrew M.
    Kim, Chang-Sei
    Ashouri, Hazar
    Inan, Omer T.
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    SCIENTIFIC REPORTS, 2016, 6
  • [5] Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time
    Stephanie L.-O. Martin
    Andrew M. Carek
    Chang-Sei Kim
    Hazar Ashouri
    Omer T. Inan
    Jin-Oh Hahn
    Ramakrishna Mukkamala
    Scientific Reports, 6
  • [6] Improved pulse transit time estimation by system identification analysis of proximal and distal arterial waveforms
    Xu, Da
    Ryan, Kathy L.
    Rickards, Caroline A.
    Zhang, Guanqun
    Convertino, Victor A.
    Mukkamala, Ramakrishna
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 301 (04): : H1389 - H1395
  • [7] Pulse Transit Time Estimation from Anacrotic Photoplethysmography waveforms
    Sameen, Aws Zuhair
    Jaafar, Rosmina
    Yahya, M. A. M.
    2017 INTERNATIONAL CONFERENCE ON ROBOTICS, AUTOMATION AND SCIENCES (ICORAS), 2017,
  • [8] Author Correction: Weighing Scale-Based Pulse Transit Time is a Superior Marker of Blood Pressure than Conventional Pulse Arrival Time
    Stephanie L.-O. Martin
    Andrew M. Carek
    Chang-Sei Kim
    Hazar Ashouri
    Omer T. Inan
    Jin-Oh Hahn
    Ramakrishna Mukkamala
    Scientific Reports, 8
  • [9] Exact transit time measurement of the pulse wave with the mechanical pulse meter
    Braun, Thomas
    INNERE MEDIZIN, 2024, 65 : S12 - S13
  • [10] Arterial pulse transit time evaluation by peripheral pulse wave measurement
    Gircys, R.
    Kazanavicius, E.
    Obcarskas, L.
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2013, 1 (01) : 52 - 58