Point of care blood ketone testing of diabetic patients in the emergency department

被引:40
|
作者
Bektas, F
Eray, O
Sari, R
Akbas, H
机构
[1] Univ Akdeniz, Sch Med, Dept Emergency Med, Antalya, Turkey
[2] Univ Akdeniz, Sch Med, Dept Endocrinol, Antalya, Turkey
[3] Univ Akdeniz, Sch Med, Dept Biochem, Antalya, Turkey
关键词
capillary ketone level; emergency room; diabetes; ketoacidosis; beta-hydroxybutyrate;
D O I
10.1081/ERC-200035231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to determine the utility of point-of-care blood ketone testing in diabetic patients presenting to the emergency department. In this prospective, observational clinical study, patients with known or newly diagnosed diabetes mellitus presenting to our tertiary care university emergency department with any nontrauma related medical complaint and a high fingerstick glucose ( > 200 mg/dL) were eligible for inclusion. Capillary blood beta-hydroxybutyrate (beta-HBA), venous blood beta-HBA level, venous blood glucose level, arterial blood gas analysis, and urine ketone dipstickstick were measured in each patient as primary outcome measures. Of the 479 diabetic patients presenting during the study period, a total of 139 diabetic patients with high capillary blood glucose level ( greater than or equal to 200 mg/dL) and a positive capillary blood beta-HBA ( greater than or equal to 0.1 mmol/L) were included in the study. Hyperketonemia ( greater than or equal to 0.42 mmol/L) was found in 48 of these patients by Sigma Diagnostics reference testing (diabetic ketosis in 35%). The calculated blood pH was less than 7.3 in 18 of these 48 patients (ketoacidosis in 31%). Capillary and venous blood beta-hydroxybutyrate levels were not statistically different from each other (P = 0.824). There was a positive correlation between capillary and venous blood beta-HBA levels (r = 0.488, P < 0.001). The sensitivity and specificity of urine ketone dipstick testing and capillary blood ketone testing in determining diabetic ketoacidosis were 66% and 78%, and 72% and 82%; and in determining hyperketonemia (both in diabetic ketosis and diabetic ketoacidosis) were 82% and 54%, and 91% and 56%, respectively. A rapid, bedside capillary blood ketone test for beta-HBA can accurately measure blood concentrations of beta-HBA in diabetic patients in an emergency department setting. This device can be used as a reliable diagnostic test to detect emergency metabolic problems in diabetic patients, such as diabetic ketosis or ketoacidosis.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [11] Blood ketone and leptin levels in diabetic patients with suspected metabolic disorder in the emergency department.
    Eray, O
    Sari, R
    Bektas, F
    Balci, MK
    DIABETOLOGIA, 2003, 46 : A241 - A241
  • [12] Point-of-care testing outcomes in an emergency department
    van Heyningen, C
    Watson, ID
    Morrice, AE
    CLINICAL CHEMISTRY, 1999, 45 (03) : 437 - 438
  • [13] Training and testing for capillary blood glucose and ketone levels on triage: impact on the early management of diabetic ketoacidosis in an emergency department
    Ena, Javier
    Amillo, Monica
    Panadero, Ana
    Rosales, Maria
    Patricia Guzman-Libreros, Angela
    Jose Navarro-Diaz, Francisco
    EMERGENCIAS, 2016, 28 (04): : 243 - 246
  • [14] Accuracy of Point-of-Care Testing for Anemia in the Emergency Department
    Osborn, Zachary T.
    Villalba, Nuria
    Derickson, Pamela R.
    Sewatsky, Thomas P.
    Wager, Abigail P.
    Freeman, Kalev
    RESPIRATORY CARE, 2019, 64 (11) : 1343 - 1350
  • [15] The portable laboratory and emergency department point-of-care testing
    van Heyningen, C
    Watson, ID
    ANNALS OF CLINICAL BIOCHEMISTRY, 1999, 36 : 531 - 531
  • [16] Reliability of point-of-care hemoglobin testing in the emergency department
    Luber, S.
    de, Give D.
    Roppolo, L.
    Todd, C.
    Sharda, R.
    Patyrak, S.
    Byrne, D.
    Pepe, P.
    ANNALS OF EMERGENCY MEDICINE, 2008, 51 (04) : 497 - 497
  • [17] Appropriateness of point-of-care testing (POCT) in an emergency department
    Di Serio, F
    Antonelli, G
    Trerotoli, P
    Tampoia, M
    Matarrese, A
    Pansini, N
    CLINICA CHIMICA ACTA, 2003, 333 (02) : 185 - 189
  • [18] Point-of-Care Influenza Testing in the Pediatric Emergency Department
    Patel, Prina
    Laurich, Vincent Matt
    Smith, Sharon
    Sturm, Jesse
    PEDIATRIC EMERGENCY CARE, 2020, 36 (11) : 515 - 518
  • [19] Impact of point-of-care testing on patients' length of stay in a large emergency department
    Parvin, CA
    Lo, SF
    Deuser, SM
    Weaver, LG
    Lewis, LM
    Scott, MG
    CLINICAL CHEMISTRY, 1996, 42 (05) : 711 - 717
  • [20] Point-of-care testing improves accuracy of STI care in an emergency department
    Huppert, Jill S.
    Taylor, Regina G.
    St Cyr, Sarah
    Hesse, Elizabeth A.
    Reed, Jennifer L.
    SEXUALLY TRANSMITTED INFECTIONS, 2013, 89 (06) : 489 - 494