Effect of a pocket compression device on hematomas, skin reactions, and comfort in patients receiving a cardiovascular implantable electronic device: a randomized controlled trial

被引:3
|
作者
Hu, Jingwen [1 ]
Zheng, Jie [2 ]
Liu, Xiaoxue [1 ]
Li, Guoliang [1 ]
Xiao, Xianghua [3 ]
机构
[1] Xi An Jiao Tong Univ, Dept Cardiol, Affiliated Hosp 1, Xian, Peoples R China
[2] Xi An Jiao Tong Univ, Clin Res Ctr, Affiliated Hosp 1, Xian, Peoples R China
[3] Xian City First Hosp, Shaanxi Eye Inst, Xian, Peoples R China
关键词
cardiovascular implantable electronic device; pocket compression device; hematomas; skin reactions; and comfort;
D O I
10.1007/s10840-021-00973-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim/objective Aim to evaluate the safety and effectiveness of a pocket compression device in patients undergoing cardiovascular implantable electronic device (CIED) implantation. Material and methods This randomized controlled trial included 54 patients in the control group (elastic adhesive tape) and 54 patients in the experimental group (pocket compression device). A sandbag was positioned over the pocket after CIED implantation, using elastic adhesive tape in the control group and a novel pocket compression device in the experimental group. The primary outcome was the incidence of pocket hematomas, and the secondary outcomes were adverse skin reactions, the need for sandbag positional adjustments, and patient comfort. Results The distributions of age, sex, and clinical and procedure characteristics was not significantly different between the two groups (P>0.05). The occurrence of hematomas was lower when using the pocket compression device than in the control group (13.0% vs. 44.4%, P<0.001). The incidence rates of hematomas of grades 1 and the grade 2 hematomas were significantly lower in the experimental group than in the control group (13.0% vs. 31.5%, 0% vs. 11.1% respectively, [all P<0.05]). The incidence rates of adverse skin reactions and sandbag positional adjustments were much lower and the patient comfort score was significantly higher in the experimental group than in the control group (all P<0.001). Conclusion A pocket compression device can significantly decrease the incidence of pocket hematomas, adverse skin reactions, and positional adjustments when patients are undergoing CIED, which can improve patient comfort and decrease the nursing workload.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 50 条
  • [1] Effect of a pocket compression device on hematomas, skin reactions, and comfort in patients receiving a cardiovascular implantable electronic device: a randomized controlled trial
    Jingwen Hu
    Jie Zheng
    Xiaoxue Liu
    Guoliang Li
    Xianghua Xiao
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 275 - 281
  • [2] Effect of a Novel Pocket Compression Device on Hematomas Following Cardiac Electronic Device Implantation in Patients Receiving Direct Oral Anticoagulants
    Fei, Ye-Ping
    Wang, Lei
    Zhu, Chun-Yan
    Sun, Jing-Chao
    Hu, Hui-Lin
    Zhai, Chang-Lin
    He, Chao-Jie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [3] Effect of pocket compression device on pocket hematoma after cardiac implantable electronic device implantation
    Prasertwitayakij, Narawudt
    Yanyongmathe, Jakkapun
    Pongbangli, Natnicha
    Nantsupawat, Teerapat
    Gunaparn, Siriluck
    Pisespongsa, Cheeranun
    Tawaditap, Chanya
    Phrommintikul, Arintaya
    Wongcharoen, Wanwarang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [4] Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection
    Garrigos, Zerelda Esquer
    George, Merit P.
    Khalil, Sarwat
    Vijayvargiya, Prakhar
    Abu Saleh, Omar M.
    Friedman, Paul A.
    Steckelberg, James M.
    DeSimone, Daniel C.
    Wilson, Walter R.
    Baddour, Larry M.
    Sohail, M. Rizwan
    OPEN FORUM INFECTIOUS DISEASES, 2019, 6 (04):
  • [5] Risk Profiles and Outcomes of Patients Receiving Antibacterial Cardiovascular Implantable Electronic Device Envelopes
    Woodard, David
    Kim, Grace
    Murrow, Jonathan R.
    Nilsson, Kent R.
    CIRCULATION, 2021, 144
  • [6] Use of Novel Compression Device Reduces the Incidence of Pocket Hematoma in Anticoagulated Patients Receiving Implantable Electronic Cardiac Devices: A Pilot Study
    Lakkireddy, Dhanunjaya
    Bartus, Krzysztof
    Nagarajan, Venkat
    Afzal, Rizwan
    Atkins, Donita
    Gunasekaran, Vidhya
    Mahapatra, Srijoy
    Swarup, Vijay
    CIRCULATION, 2016, 134
  • [7] Same-Day Device Reimplantation Following Cardiovascular Implantable Electronic Device Extraction for Isolated Pocket Infection
    Kim, Susan S.
    Philips, Binu
    Smelley, Matthew
    Shah, Dipak
    Weisberg, Ian
    Mishra, Akshay
    Lin, Albert C.
    Beshai, John F.
    Knight, Bradley P.
    Burke, Martin C.
    CIRCULATION, 2009, 120 (18) : S649 - S649
  • [8] MICROBIOLOGICAL DIFFERENCES OF POCKET VS. NON-POCKET CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICE INFECTIONS
    Kaji, A.
    Lee, D. H.
    Kohut, A.
    Kutalek, S.
    CARDIOLOGY, 2013, 125 : 335 - 335
  • [9] Factors related to the skin thickness of cardiovascular implantable electronic device pockets
    Yatomi, Atsusuke
    Takami, Mitsuru
    Fukuzawa, Koji
    Kiuchi, Kunihiko
    Sakai, Jun
    Nakamura, Toshihiro
    Sonoda, Yusuke
    Takahara, Hiroyuki
    Nakasone, Kazutaka
    Yamamoto, Kyoko
    Suzuki, Yuya
    Tani, Kenichi
    Iwai, Hidehiro
    Nakanishi, Yusuke
    Hirata, Ken-ichi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (08) : 1847 - 1856
  • [10] Differences of Mortality Rates between Pocket and Nonpocket Cardiovascular Implantable Electronic Device Infections
    Lee, Dong Heun
    Gracely, Edward J.
    Aleem, Sarah Y.
    Kutalek, Steven P.
    Vielemeyer, Ole
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (12): : 1456 - 1463