Shear Wave Elastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects

被引:17
|
作者
Baur, Daniel [1 ]
Schwabl, Christoph [1 ]
Kremser, Christian [1 ]
Taljanovic, Mihra S. [2 ]
Widmann, Gerlig [1 ]
Sconfienza, Luca Maria [3 ,4 ]
Sztankay, Judith [5 ]
Feuchtner, Gudrun [1 ]
Klauser, Andrea S. [1 ]
机构
[1] Med Univ Innsbruck, Radiol Dept, Anichstr 35, A-6020 Innsbruck, Austria
[2] Univ Arizona, Banner Univ Med Ctr, Coll Med, Dept Med Imaging, Tucson, AZ 85724 USA
[3] IRCCS Ist Ortoped Galeazzi, Unit Diagnost & Intervent Radiol, I-20097 Milan, Italy
[4] Univ Milan, Dipartimento Sci Biomed Salute, I-20133 Milan, Italy
[5] Med Univ Innsbruck, Dept Radiotherapy, A-6020 Innsbruck, Austria
关键词
color doppler ultrasonography; elastography; plantar fasciitis; plantar fascia; shear wave; REAL-TIME SONOELASTOGRAPHY; HEEL PAIN; ULTRASOUND;
D O I
10.3390/jcm10112351
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of this study was to evaluate plantar fasciae of healthy subjects and patients with plantar fasciitis by shear wave velocity (SWV) and stiffness with correlation to B-Mode and color Doppler ultrasonography (CDUS) and to establish cut-off values. Methods: This observational study was conducted with the approval of the Institutional Review Boards (IRBs) of our institution. 108 unilateral plantar fasciae were evaluated by including 87 consecutive patients (mean age 51.7; range: 29-82) (66 women and 21 men) with plantar fasciitis and 21 asymptomatic age matched healthy volunteers (mean age 47.3; range: 32-58) (15 women and 6 men). All patients were prospectively imaged between July 2018 and March 2019. B-mode US was used to measure thickness and CDUS to grade vascularity. SWE measurements were repeated 3 times and mean was used for statistical analysis. Results: Mean SWV value in healthy subjects was 6.94 m/s and in patients 4.98 m/s with a mean stiffness value of 152.88 kPa and 93.54 kPa respectively (p < 0.001). For SWV a cut-off value of 6.16 m/s had a specificity of 80.95% and sensitivity of 79.31%. For stiffness a cut-off value of 125.57 kPa had a specificity of 80.95% and sensitivity of 80.46%. No correlation to CDUS was found. The mean thickness of healthy fascias was 3.3 mm (range 2.4-3.9) compared to 6.1 mm (range 2.0-22.0) in plantar fasciitis (p < 0.001) with no correlation to SWV or to stiffness (r(2) = 0.02, p = 0.06). Conclusion: SWE allows quantitative assessment of plantar fascia stiffness, which decreases in patients with plantar fasciitis. No correlation to the thickness of the plantar fascia was found, therefore it represents an independent factor for the diagnosis of plantar fasciitis and could be helpful in addition to thickness measurement in unclear cases.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Real-time Sonoelastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects
    Sconfienza, Luca Maria
    Silvestri, Enzo
    Orlandi, Davide
    Fabbro, Emanuele
    Ferrero, Giulio
    Martini, Chiara
    Sardanelli, Francesco
    Cimmino, Marco Amedeo
    RADIOLOGY, 2013, 267 (01) : 195 - 200
  • [2] Evaluation of plantar fasciopathy shear wave elastography: a comparison between patients and healthy subjects
    Schillizzi, Giuseppe
    Alviti, Federica
    D'Ercole, Chiara
    Elia, Daniela
    Agostini, Francesco
    Mangone, Massimiliano
    Paoloni, Marco
    Bernetti, Andrea
    Pacini, Patrizia
    Polti, Giorgia
    Minafra, Paolo
    Cantisani, Vito
    JOURNAL OF ULTRASOUND, 2021, 24 (04) : 417 - 422
  • [3] Evaluation of plantar fasciopathy shear wave elastography: a comparison between patients and healthy subjects
    Giuseppe Schillizzi
    Federica Alviti
    Chiara D’Ercole
    Daniela Elia
    Francesco Agostini
    Massimiliano Mangone
    Marco Paoloni
    Andrea Bernetti
    Patrizia Pacini
    Giorgia Polti
    Paolo Minafra
    Vito Cantisani
    Journal of Ultrasound, 2021, 24 : 417 - 422
  • [4] Shear Wave Elastography (SWE) for the Evaluation of Patients with Plantar Fasciitis
    Gatz, Matthias
    Bejder, Ljudmila
    Quack, Valentin
    Schrading, Simone
    Dirrichs, Timm
    Tingart, Markus
    Kuhl, Christiane
    Betsch, Marcel
    ACADEMIC RADIOLOGY, 2020, 27 (03) : 363 - 370
  • [5] Shear wave elastography for treatment monitoring of plantar fasciitis
    Gatz, Matthias
    Betsch, Marcel
    Quack, Valentin
    Bejder, Ljudmila
    Schrading, Simone
    Tingart, Markus
    Dirrichs, Timm
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2020, 60 (08): : 1137 - 1147
  • [6] Plantar Fascia Thickness and Stiffness in Healthy Individuals vs Patients With Plantar Fasciitis
    Thanwisate, Tanwarat
    Siriwanarangsun, Palanan
    Piyaselakul, Sitha
    Tharmviboonsri, Theerawoot
    Chuckpaiwong, Bavornrit
    FOOT & ANKLE INTERNATIONAL, 2024, 45 (11) : 1270 - 1278
  • [7] Effect of plantar fascia-specific stretching and Achilles tendon stretching on shear wave elasticity of the plantar fascia in healthy subjects
    Sugino, Yuki
    Yoshimura, Ichiro
    Hagio, Tomonobu
    Ishimatsu, Tetsuro
    Nagatomo, Masaya
    Yamamoto, Takuaki
    FOOT AND ANKLE SURGERY, 2023, 29 (03) : 208 - 212
  • [8] Elasticity evaluation of the plantar fascia: A shear wave elastography study involving 33 early-stage plantar fasciopathy subjects
    Jiang, Zhen-Zhen
    Shen, Hua-Liang
    Zhang, Qi
    Ye, Gang
    Li, Xiu-Cheng
    Liu, Xia-Tian
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [9] Utility of Shear Wave Elastography for the Diagnosis of Plantar Fasciitis: Comparison Between Symptomatic and Asymptomatic Sides in Unilaterally Affected Patients
    Thakur, Rajani
    Aluka, Sundeep Kund Reddy
    Srikanth, Rama
    Hussain, Syed Maqsood
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [10] The Correlation Between Plantar Fascia Thickness and Symptoms of Plantar Fasciitis
    Mahowald, Sarah
    Legge, Bradford S.
    Grady, John F.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2011, 101 (05) : 385 - 389