A versatile and automated microfluidic platform for a quantitative magnetic bead based protocol: application to gluten detection

被引:8
|
作者
Parent, Charlotte [1 ]
Laurent, Patricia [1 ]
Goujon, Charles-Elie [2 ]
Mermet, Xavier [3 ]
Keiser, Armelle [1 ]
Boizot, Francois [1 ]
Charles, Raymond [1 ]
Audebert, Lucas [4 ]
Fouillet, Yves [1 ]
Cubizolles, Myriam [1 ]
机构
[1] Univ Grenoble Alpes, Technol Healthcare & Biol Div, Microfluid Syst & Bioengn Lab, CEA,LETI, F-38000 Grenoble, France
[2] Univ Grenoble Alpes, YSPOT, CEA Tech, CEA, F-38000 Grenoble, France
[3] Univ Grenoble Alpes, Technol Healthcare & Biol Div, LSIV, CEA,LETI, F-38000 Grenoble, France
[4] Univ Grenoble Alpes, Technol Healthcare & Biol Div, LS2P, CEA,LETI, F-38000 Grenoble, France
关键词
DIGITAL MICROFLUIDICS; CHIP; ELISA; IMMUNOASSAYS; DESIGN; SYSTEM; ASSAYS; LAB;
D O I
10.1039/d2lc00328g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microfluidic platform for the integration of multi-step biological assays has been developed. The presented system is a unique instrument compatible with microfluidic chips for various applications based on bead manipulation. Two examples of microfluidic cartridges are presented here. The first one contains two rows of eight chambers (40 and 80 mu L), six reagent inlets, eight testing solution (calibrators and samples) inlets and eight outlets to reproduce precisely each step of a biological assay. This configuration is versatile enough to integrate many different biological assays and save a lot of development time. The second architecture is dedicated to one specific protocol and is completely automated from the standard and sample dilutions to the optical detection. Linear dilutions have been integrated to prepare automatically a range of standard concentrations and outlets have been modified for integrated colorimetric detection. The technology uses pneumatically collapsible chambers to perform all the fluidic operations for a fully automated protocol such as volume calibrations, fluid transport, mixing, and washing steps. A programmable instrument with a software interface has been developed to adapt rapidly a protocol to this cartridge. As an example, these new microfluidic cartridges have been used to successfully perform an immunoassay for gluten detection in the dynamic range of 10-30 ppm with good sensitivity (2 ppm) and specificity.
引用
收藏
页码:3147 / 3156
页数:11
相关论文
共 50 条
  • [31] An integrated and sensitive detection platform for biosensing application based on Fe@Au magnetic nanoparticles as bead array carries
    Liu, Hongna
    Li, Song
    Liu, Lishang
    Tian, Lan
    He, Nongyue
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1442 - 1448
  • [32] Microfluidic bead-based sensing platform for monitoring kinase activity
    Lee, Seung Hwan
    Rhee, Hyun-Woo
    van Noort, Danny
    Lee, Hong Jai
    Park, Hee Ho
    Shin, Ik-Soo
    Hong, Jong-In
    Park, Tai Hyun
    BIOSENSORS & BIOELECTRONICS, 2014, 57 : 1 - 9
  • [33] Automated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkers
    Reza Riahi
    Seyed Ali Mousavi Shaegh
    Masoumeh Ghaderi
    Yu Shrike Zhang
    Su Ryon Shin
    Julio Aleman
    Solange Massa
    Duckjin Kim
    Mehmet Remzi Dokmeci
    Ali Khademhosseini
    Scientific Reports, 6
  • [34] Application of Magnonic Crystals in Magnetic Bead Detection
    Manzin, Alessandra
    Ferrero, Riccardo
    Vicentini, Marta
    NANOMATERIALS, 2022, 12 (19)
  • [35] DropLab: an automated magnetic digital microfluidic platform for sample-to-answer point-of-care testing-development and application to quantitative immunodiagnostics
    Hu, Xuyang
    Gao, Xiangyu
    Chen, Songlin
    Guo, Jinhong
    Zhang, Yi
    MICROSYSTEMS & NANOENGINEERING, 2023, 9 (01)
  • [36] An integrated microfluidic biochemical detection system with magnetic bead-based sampling and analysis capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, : 447 - 450
  • [37] A Magnetic-bead Based Microfluidic System for Automatic C-reactive protein Detection
    Lee, Wen-Bin
    Lin, Hsin-I
    Shiesh, Shu-Chu
    Lee, Gwo-Bin
    MNHMT2009, VOL 1, 2010, : 257 - 260
  • [38] Automated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkers
    Riahi, Reza
    Shaegh, Seyed Ali Mousavi
    Ghaderi, Masoumeh
    Zhang, Yu Shrike
    Shin, Su Ryon
    Aleman, Julio
    Massa, Solange
    Kim, Duckjin
    Dokmeci, Mehmet Remzi
    Khademhosseini, Ali
    SCIENTIFIC REPORTS, 2016, 6
  • [39] Integrated microfluidic chip for cell culture and stimulation and magnetic bead-based biomarker detection
    Ruffert, Christine
    Ramadan, Qasem
    Ruegg, Matthieu
    Vergères, Guy
    Gijs, Martin A. M.
    Micro and Nanosystems, 2014, 6 (01) : 61 - 68
  • [40] Digital microfluidic platform for automated detection of human chorionic gonadotropin
    Piao, Yuhao
    Wang, Xingbo
    Xia, Huanming
    Wang, Weiqiang
    MICROFLUIDICS AND NANOFLUIDICS, 2019, 23 (01)