Reproducibility and comparability of insulin sensitivity indices measured by stable-label intravenous glucose tolerance test

被引:0
|
作者
Hovorka, R [1 ]
Bannister, P [1 ]
Eckland, DJA [1 ]
Halliday, D [1 ]
Murley, DN [1 ]
Rees, SE [1 ]
Young, MA [1 ]
机构
[1] City Univ London, Ctr Measurement & Informat Med, Metab Modelling Grp, London EC1V 0HB, England
关键词
minimal model; insulin sensitivity; reproducibility; 6,6-H-2-glucose; hepatic glucose output;
D O I
10.1002/(SICI)1096-9136(199803)15:3<234::AID-DIA564>3.0.CO;2-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have investigated the reproducibility of (1) insulin sensitivity (S-I*) and glucose effectiveness (S-G*) as measured by the stable-label (one compartment) minimal model, and (2) insulin sensitivity (S-lb*), plasma clearance rate (PCR), basal hepatic output (HGO(b)), and total hepatic glucose output (HGO(0-240)) as measured by the novel stable-label two compartment model of glucose disappearance during labelled intravenous glucose tolerance test (IVGTT) using 6,6-H-2-glucose. Ten normal male subjects were studied on two occasions one week apart. Both models provided estimates of all indices with acceptable precision (CV of parameter estimates less than or equal to 50 %). The within subject CVs of S-1* and S-lb* were comparable (17 % vs 19 %) as were the within subject CVs of S-G* and PCR (13 % vs 16 %). A highly significant linear relationship was observed between S-lb* and S-1* (0.303 +/- 0.046 ml k(-1) min(-1) per mU l(-1) vs 13.04 +/- 1.89 10(-4) min(-1) per mU l(-1), y = 0.0037 x + 0.0002, r = 0.90, p <0.001; mean +/- SE), but not between PCR and S-G* (1.98 +/- 0.15 ml kg(-1) min(-1) vs 0.0089 +/- 0.0005 min(-1), r(s) = 0.34, NS). The two compartment model provided a plausible time-profile of hepatic glucose output during IVGTT, reproducible estimates of HGO(b) (1.96 +/- 0.18 mg kg(-1) min(-1), 15 %; mean +/- SE, within subject CV), and a highly reproducible HGO(0-240) (7 %; within subject CV). We conclude that the stable-label (one compartment) minimal model and the stable-label two compartment model provide reproducible estimates of parameters of glucose kinetics in normal subjects. Insulin sensitivity indices estimated by the two models are strongly linearly related. (C) 1998 by John Wiley & Sons, Ltd.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 50 条
  • [31] Validation of insulin sensitivity indices from oral glucose tolerance test parameters in obese children and adolescents
    Yeckel, CW
    Weiss, R
    Dziura, J
    Taksali, SE
    Dufour, S
    Burgert, TS
    Tamborlane, WV
    Caprio, S
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (03): : 1096 - 1101
  • [32] Validation of simple indices to assess insulin sensitivity based on the oral glucose tolerance test in the Japanese population
    Kanauchi, M
    Tsujimoto, N
    Hashimoto, T
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2002, 55 (03) : 229 - 235
  • [33] Glucose absorption and insulin sensitivity from oral glucose tolerance test
    Natalucci, S
    Di Nardo, F
    Staffolani, P
    De Marzi, C
    Morosini, P
    Burattini, R
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 2758 - 2760
  • [34] Evaluation of insulin sensitivity and glucose effectiveness during a standardized breakfast test: comparison with the minimal model analysis of an intravenous glucose tolerance test
    Aloulou, K
    Brun, JF
    Mercier, J
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2006, 55 (05): : 676 - 690
  • [35] The importance of intravenous glucose tolerance test glucose stimulus for the evaluation of insulin secretion
    Godsland, Ian F.
    Johnston, Desmond G.
    Alberti, Kgmm
    Oliver, Nick
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [36] INSULIN SENSITIVITY AND GLUCOSE CLEARANCE QUANTIFIED IN HUMANS FROM LABELED INTRAVENOUS GLUCOSE-TOLERANCE TEST AND MINIMAL MODEL
    CAUMO, A
    GIACCA, A
    MORGESE, M
    RIVOLTA, G
    POZZA, G
    MICOSSI, P
    COBELLI, C
    DIABETOLOGIA, 1987, 30 (07) : A506 - A506
  • [37] Estimating insulin sensitivity from oral glucose tolerance test
    Boroujerdi, MA
    Bowes, SB
    Umpleby, AM
    RussellJones, DL
    Jones, RH
    Lowy, C
    Sonksen, PH
    DIABETOLOGIA, 1997, 40 : 1103 - 1103
  • [38] Familial resemblance for glucose and insulin metabolism indices derived from an intravenous glucose tolerance test in Blacks and Whites of the HERITAGE Family Study
    Hong, Y
    Weisnagel, SJ
    Rice, T
    Sun, G
    Mandel, SA
    Gu, C
    Rankinen, T
    Gagnon, J
    Leon, AS
    Skinner, JS
    Wilmore, JH
    Bergman, RN
    Bouchard, C
    Rao, DC
    CLINICAL GENETICS, 2001, 60 (01) : 22 - 30
  • [39] Comparison among the euglycemic-hyperinsulinemic clamp, insulin-modified frequently sampled intravenous glucose tolerance test, and oral glucose tolerance test for assessment of insulin sensitivity in healthy Standardbreds
    Pratt-Phillips, Shannon E.
    Geor, Ray J.
    McCutcheon, L. Jill
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (01) : 84 - 91
  • [40] Comparison of estimates of insulin sensitivity and B-cell function derived from the oral glucose tolerance test versus the intravenous glucose tolerance test and minimal model
    Howell, WM
    Prigeon, RL
    Fujimoto, WY
    Kahn, SE
    DIABETES, 1998, 47 : A179 - A179