Radon in tube-well drinking water and indoor air

被引:12
|
作者
Sonkawade, RG
Ram, R
Kanjilal, DK
Ramola, RC
机构
[1] Ctr Nucl Sci, New Delhi 110067, India
[2] HNB Garhwal Univ, Dept Phys, Tehri Garhwal, India
关键词
indoor air; tube-wells; drinking water; pH;
D O I
10.1177/1420326X04046464
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High radon concentration in well water influences the indoor radon concentration when used as a domestic water supply. Radon levels were measured in indoor air and different tube-well water samples at the Nuclear Science Centre (NSC) premises. The ground-water from these tube-wells is used for drinking by the residents of the NSC premises. The radon concentrations in drinking water and the indoor air of the NSC premises were measured by using AlphaGuard. Radon levels recorded were more or less the same in all water samples and were found to vary from 1645Bq.m(-3) to 3869Bq.m(-3). Even when de-ionised, the radon concentration in the water was measured in the range from 1569Bq.m(-3) to 2213Bq.m(-3). The pH value of the water samples was also measured: no correlation was observed between radon concentration and the pH of the water samples. In addition, radon levels were also measured in some houses at the NSC premises using the same technique. The indoor radon level was found to vary from 3Bq.m(-3) to 75Bq.m(-3). The radon levels in kitchens and bedrooms were found to be slightly higher than those in other parts of the house. The indoor radon concentration was found to be highest at night and lowest in the afternoon. However, the measured radon levels in both the drinking water and the indoor air are well below the UNSCEAR recommended levels.
引用
收藏
页码:383 / 385
页数:3
相关论文
共 50 条
  • [21] Contamination by arsenic and other trace elements in tube-well water and its risk assessment to humans in Hanoi, Vietnam
    Agusa, T
    Kunito, T
    Fujihara, J
    Kubota, R
    Minh, TB
    Trang, PTK
    Iwata, H
    Subramanian, A
    Viet, PH
    Tanabe, S
    ENVIRONMENTAL POLLUTION, 2006, 139 (01) : 95 - 106
  • [22] FUNCTIONAL STUDY OF FACTORS AFFECTING BENEFITS FROM TUBE-WELL IRRIGATION IN ORISSA
    CHAMPATI, M
    HOTA, BC
    INDIAN JOURNAL OF AGRICULTURAL SCIENCES, 1976, 46 (10): : 471 - 476
  • [23] Waterborne radon pollution of indoor air
    Mose, DG
    Sullivan, KT
    Mushrush, GW
    Slone, JE
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1996, 31 (06): : 1407 - 1421
  • [24] Deep hand tube-well water for achieving sustainable development goal in arsenic affected villages: Bangladesh experience
    Hoque, B. A.
    Khanam, S.
    Zahid, M. A.
    Hoque, M. M.
    Akter, N.
    Mahmud, M. N.
    Huque, S.
    Ahmed, S.
    ENVIRONMENTAL ARSENIC IN A CHANGING WORLD (AS2018), 2018, : 633 - 635
  • [25] Determination of Arsenic and Other Heavy Metals in Hand Pump and Tube-Well Ground Water of Khairpur, Sindh, Pakistan
    Jakhrani, Mushatque Ali
    Chaudhray, Abdul Jabbar
    Mukhtar-ul-Hassan
    Malik, Khan Muhammad
    Jakhrani, Ashfaque Ahmed
    Mazari, Muhammad Qasim
    PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND COMPUTER SCIENCE, 2009, : 271 - +
  • [26] Cancer risks from radon in indoor air and drinking water in Sweden.: The Swedish Radiation Protection Authority's risk assessment
    Mjönes, L
    Falk, R
    Natural Radiation Environment VII, 2005, 7 : 604 - 611
  • [27] RADON CONCENTRATIONS IN WATER AND INDOOR AIR IN NORTH-WEST REGIONS OF ROMANIA
    Nita, D. C.
    Moldovan, M.
    Sferle, T.
    Ona, V. D.
    Burghele, B. D.
    ROMANIAN JOURNAL OF PHYSICS, 2013, 58 : S196 - S201
  • [28] RADON FROM DRINKING-WATER - EVALUATION OF WATER-BORNE TRANSFER INTO HOUSE AIR
    HESS, CT
    VIETTI, MA
    MAGE, DT
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 1987, 9 (3-4) : 68 - 73
  • [29] RADON IN WATER AND AIR
    MAY, JC
    CHEMICAL & ENGINEERING NEWS, 1992, 70 (47) : 2 - 2
  • [30] Measurement of radon and thoron concentrations in the indoor atmosphere and drinking water of eastern Doon valley, India
    Choubey, VM
    Bartarya, SK
    Negi, MS
    Ramola, RC
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) : 191 - 196