Implant Angulation Effect on the Fracture Resistance of Monolithic Zirconia Custom Abutments: An In Vitro Study

被引:7
|
作者
Katsavochristou, Anastasia [1 ,2 ]
Sierraalta, Marianella [2 ]
Saglik, Berna [2 ]
Koumoulis, Dimitrios [3 ]
George, Furat [2 ]
Razzoog, Michael [2 ]
机构
[1] Univ Kentucky, Div Prosthodont, Coll Dent, Lexington, KY 40536 USA
[2] Univ Michigan, Sch Dent, Biol & Mat Sci, Div Prosthodont, Ann Arbor, MI 48109 USA
[3] Univ Kentucky, Ctr Appl Energy Res, 3572 Iron Works Pike, Lexington, KY 40511 USA
关键词
angulation; bioengineering mechanics; fracture resistance; implant; monolithic; zirconia abutment; INTERNAL CONNECTION; MAXILLARY ANTERIOR; STRENGTH; TITANIUM; CROWNS; RESTORATIONS; LOAD;
D O I
10.1111/jopr.13127
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To investigate the fracture resistance and performance of zirconia when employed for the fabrication of implant abutments with different angulations, simulating anterior maxillary oral rehabilitation. Materials and Methods Forty-five monolithic zirconia custom abutments of internal conical implant connection were CAD/CAM designed and fabricated. The specimens were divided into three groups (n = 15/group) according to implant-to-abutment angulation. The angulations used were; 0 degrees, 15 degrees, and 25 degrees. The abutments were loaded until failure at 135 degrees using the Universal Testing Machine (Instron, Canton, MA). Collected data were statistically analyzed using one-way ANOVA and post hoc Tukey test. Results Mean (+/- standard deviation) load at fracture of the zirconia abutments for the three groups were 962.37 +/- 93.81 N (Gr15) > 718.25 +/- 93.71 N (Gr25) > 534.05 +/- 133.77 N (Gr0). Statistically significant difference (p < 0.0001) was found between all groups; Gr0 vs. Gr15, Gr0 vs. Gr25, Gr15 vs. Gr25. Conclusions Contrary to expectations, the non-angulated monolithic zirconia abutments presented the lowest fracture resistance values. Angulating the abutments 15 or 25 degrees, following the palatal resorption pattern of the premaxilla, significantly increased the in vitro fracture resistance.
引用
收藏
页码:394 / 400
页数:7
相关论文
共 50 条
  • [41] Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry
    Frank P. Nothdurft
    Konrad Neumann
    Andreas W. Knauber
    Clinical Oral Investigations, 2014, 18 : 1467 - 1472
  • [42] Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments
    Elsayed, Adham
    Wille, Sebastian
    Al-Akhali, Majed
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) : 20 - 27
  • [43] Comparative Study of Dental Custom CAD-CAM Implant Abutments and Dental Implant Stock Abutments
    Tartea, Daniel Adrian
    Ionescu, Mihaela
    Manolea, Horia Octavian
    Mercut, Veronica
    Obadan, Eugenia
    Amarascu, Marina Olimpia
    Marasescu, Petre Costin
    Daguci, Luminita
    Popescu, Sanda Mihaela
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [44] In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
    Choi, Jae-Won
    Kim, So-Yeun
    Bae, Ji-Hyeon
    Bae, Eun-Bin
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04): : 244 - 251
  • [45] Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging
    Atsu, Saadet Saglam
    Aksan, M. Emin
    Bulut, Ali Can
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 622 - 630
  • [46] Comparison of Fracture Resistance and Fit Accuracy of Customized Zirconia Abutments with Prefabricated Zirconia Abutments in Internal Hexagonal Implants
    Park, Jong-Il
    Lee, Yoon
    Lee, Jin-Han
    Kim, Yu-Lee
    Bae, Ji-Myung
    Cho, Hye-Won
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 769 - 778
  • [47] The impact of luting agents and stiffness of implant-abutments on marginal adaptation, chipping, and fracture resistance of zirconia crowns
    Schaefer, Lina
    Winkler, Cornelia
    Brandl, Genoveua
    Eckl, Sebastian
    Preis, Verena
    Behr, Michael
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 279 - 291
  • [48] In vitro fracture resistance of implant-supported terminal zirconia cantilevered frameworks
    Al Bayati, Tabark Shihab
    Muhsin, Saja Ali
    EUROPEAN ORAL RESEARCH, 2025, 59 (01) : 27 - 32
  • [49] Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments
    Nossair, Shereen Ahmed
    Aboushelib, Moustafa N.
    Morsi, Tarek Salah
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 543 - 548
  • [50] Fracture Strength of Monolithic All-Ceramic Crowns on Titanium Implant Abutments
    Weyhrauch, Michael
    Igiel, Christopher
    Scheller, Herbert
    Weibrich, Gernot
    Lehmann, Karl Martin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (02) : 304 - 309