The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacement

被引:45
|
作者
Ma, H.-M. [1 ]
Lu, Y.-C. [1 ]
Kwok, T.-G. [1 ]
Ho, F.-Y. [1 ]
Huang, C.-Y. [1 ]
Huang, C.-H. [1 ]
机构
[1] Mackay Mem Hosp, Biomech Lab, Dept Orthopaed Surg, Taipei, Taiwan
来源
关键词
D O I
10.1302/0301-620X.89B3.18276
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the most controversial issues in total knee replacement is whether or not to resurface the patella. In order to determine the effects of different designs of femoral component on the conformity of the patellofemoral joint, five different knee prostheses were investigated. These were Low Contact Stress, the Miller-Galante II, the NexGen, the Porous-Coated Anatomic, and the Total Condylar prostheses. Three-dimensional models of the prostheses and a native patella were developed and assessed by computer. The conformity of the curvature of the five different prosthetic femoral components to their corresponding patellar implants and to the native patella at different angles of flexion was assessed by measuring the angles of intersection of tangential lines. The Total Condylar prosthesis had the lowest conformity with the native patella ( mean 8.58 degrees; 0.14 degrees to 29.9 degrees) and with its own patellar component ( mean 11.36 degrees; 0.55 degrees to 39.19 degrees). In the other four prostheses, the conformity was better ( mean 2.25 degrees; 0.02 degrees to 10.52 degrees) when articulated with the corresponding patellar component. The Porous-Coated Anatomic femoral component showed better conformity ( mean 6.51 degrees; 0.07 degrees to 9.89 degrees) than the Miller-Galante II prosthesis ( mean 11.20 degrees; 5.80 degrees to 16.72 degrees) when tested with the native patella. Although the Nexgen prosthesis had less conformity with the native patella at a low angle of flexion, this improved at mid ( mean 3.57 degrees; 1.40 degrees to 4.56 degrees) or high angles of flexion ( mean 4.54 degrees; 0.91 degrees to 9.39 degrees), respectively. The Low Contact Stress femoral component had the best conformity with the native patella ( mean 2.39 degrees; 0.04 degrees to 4.56 degrees). There was no significant difference ( p > 0.208) between the conformity when tested with the native patella or its own patellar component at any angle of flexion. The geometry of the anterior flange of a femoral component affects the conformity of the patellofemoral joint when articulating with the native patella. A more anatomical design of femoral component is preferable if the surgeon decides not to resurface the patella at the time of operation.
引用
收藏
页码:408 / 412
页数:5
相关论文
共 50 条
  • [21] The effect of insert conformity and material on total knee replacement wear
    Abdelgaied, Abdellatif
    Brockett, Claire L.
    Liu, Feng
    Jennings, Louise M.
    Jin, Zhongmin
    Fisher, John
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) : 98 - 106
  • [22] THE PATELLOFEMORAL COMPONENT OF TOTAL KNEE ARTHROPLASTY
    BRICK, GW
    SCOTT, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (231) : 163 - 178
  • [23] THE PATELLOFEMORAL JOINT IN TOTAL KNEE ARTHROPLASTY
    RAND, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (04): : 612 - 620
  • [24] Total knee arthroplasty for the patellofemoral joint
    Hanby, CK
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (07): : 1391 - 1392
  • [25] Component design affecting patellofemoral complications after total knee arthroplasty
    Theiss, SM
    Kitziger, KJ
    Lotke, PS
    Lotke, PA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (326) : 183 - 187
  • [26] Conformity design can change the effect of tibial component malrotation on knee biomechanics after total knee arthroplasty
    Zhang, Qida
    Peng, Yinghu
    Chen, Zhenxian
    Jin, Zhongmin
    Qin, Ling
    CLINICAL BIOMECHANICS, 2023, 105
  • [27] External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty
    Terashima, Takashi
    Onodera, Tomohiro
    Sawaguchi, Naohiro
    Kasahara, Yasuhiko
    Majima, Tokifumi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) : 3266 - 3272
  • [28] External rotation of the femoral component decreases patellofemoral contact stress in total knee arthroplasty
    Takashi Terashima
    Tomohiro Onodera
    Naohiro Sawaguchi
    Yasuhiko Kasahara
    Tokifumi Majima
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3266 - 3272
  • [29] The patellofemoral joint in total knee arthroplasty - Is the design of the trochlea the critical factor?
    Kulkarni, SK
    Freeman, MAR
    Poal-Manresa, JC
    Asencio, JI
    Rodriguez, JJ
    JOURNAL OF ARTHROPLASTY, 2000, 15 (04): : 424 - 429
  • [30] The effects of conformity and load in total knee replacement
    Kuster, MS
    Horz, S
    Spalinger, E
    Stachowiak, GW
    Gächter, A
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (375) : 302 - 312