Influence of Substrate Temperature on Adhesion Strength of TiN Coating of Biomedical Ti-13Zr-13Nb Alloy

被引:7
|
作者
Shah, A. [1 ]
Izman, S. [2 ]
Abdul-Kadir, Mohammed Rafiq [3 ]
Mas-Ayu, H. [4 ]
机构
[1] Univ Pendidikan Sultan Idris, Fac Tech & Vocat, Tanjong Malim 35900, Perak, Malaysia
[2] Univ Teknol Malaysia, Fac Mech Engn, Skudai 81310, Johor, Malaysia
[3] Univ Teknol Malaysia, Fac Biosci & Med Engn, Skudai 81310, Johor, Malaysia
[4] Univ Malaysia Pahang, Fac Mech Engn, Pekan 26300, Pahang, Malaysia
关键词
Biomaterial; Ti-13Zr-13Nb; Adhesion strength; Sustainable; TiN and CAPVD; FRETTING FATIGUE DAMAGE; NITRIDE THIN-FILMS; TI-6AL-4V ALLOY; TITANIUM-ALLOYS; SLIDING WEAR; STEEL; BEHAVIOR; PVD; CORROSION; FLUID;
D O I
10.1007/s13369-017-2647-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Adhesion strength between the coating and the substrate is considered as a significant factor, which may help determine both the successful implantation and the long-term stability of any coated implant. A weakly adhered coating on a medical implant may delaminate after the process of implantation, which in turn may severely limit the effectiveness along with the life of the implant itself. Related previous studies have shown that process parameters may have a direct influence on the quality of TiN coating. In the present work, the effect of substrate temperature on adhesion strength of TiN coating on Ti-13Zr-13Nb biomedical grade alloy was investigated. The coating parameter, which varied in this study, was the substrate temperature (i.e., 100, 200 and 300 degrees C). The adhesion strength of TiN coating was examined by means of scratch testing method. In addition, calibrated optical images were also used to verify the total coating failures on the scratched coated samples. Results indicated that an increase observed in the substrate temperature may have resulted in a decrease in the microdroplet form on TiN coating. In contrast, the adhesion strength of TiN coating was observed to equally increase when substrate temperature increased. It is believed that the higher mobility of atom at a higher substrate temperature (i.e., 300 degrees C) filling up the defect appears on the surface to provide a mechanical interlock and thus providing better adhesion strength.
引用
收藏
页码:4737 / 4742
页数:6
相关论文
共 50 条
  • [21] Influence of microstructure on tensile strength and fracture toughness of a Ti-13Nb-13Zr alloy
    Fu, YY
    Yu, ZT
    Zhou, L
    Wang, KG
    RARE METAL MATERIALS AND ENGINEERING, 2005, 34 (06) : 881 - 885
  • [22] Electrochemical Preparation of Porous Ti-13Zr-13Nb Alloy and It's Corrosion Behavior in Ringer's Solution
    Yu, Tang
    Yin, Huayi
    Zhou, Yi
    Wang, Yining
    Zhu, Hua
    Wang, Dihua
    MATERIALS TRANSACTIONS, 2017, 58 (03) : 326 - 330
  • [23] Determinants of the surface quality, density and dimensional correctness in selective laser melting of the Ti-13Zr-13Nb alloy
    Seramak, Tomasz
    Zasinska, Katarzyna
    Mesnard, Michel
    Bednarz, Karolina
    Fic, Paulina
    Zielinski, Andrzej
    MATERIAUX & TECHNIQUES, 2018, 106 (04):
  • [24] Constitutive modeling and fracture behavior of a biomedical Ti-13Nb-13Zr alloy
    Bobbili, Ravindranadh
    Madhu, Vemuri
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2017, 700 : 82 - 91
  • [25] Effects of heat treatment on evolution of microstructure of boron free and boron containing biomedical Ti-13Zr-13Nb alloys
    Majumdar, Pallab
    MICRON, 2012, 43 (08) : 876 - 886
  • [26] Investigation of passive films grown on biocompatible Ti-50Zr and Ti-13Zr-13Nb alloys by XPS
    Oliveira, NTC
    Biaggio, SR
    Nascente, PAP
    Rocha, RC
    Bocchi, N
    SURFACE AND INTERFACE ANALYSIS, 2006, 38 (04) : 410 - 412
  • [27] Influence of hydroxyapatite on the corrosion resistance of the Ti-13Nb-13Zr alloy
    Laís T. Duarte
    Sonia R. Biaggio
    Romeu C. Rocha-Filho
    Nerilso Bocchi
    Journal of Materials Science: Materials in Medicine, 2009, 20 : 1009 - 1015
  • [28] Influence of hydroxyapatite on the corrosion resistance of the Ti-13Nb-13Zr alloy
    Duarte, Lais T.
    Biaggio, Sonia R.
    Rocha-Filho, Romeu C.
    Bocchi, Nerilso
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 (05) : 1009 - 1015
  • [29] Wear response of heat-treated Ti-13Zr-13Nb alloy in dry condition and simulated body fluid
    Majumdar, P.
    Singh, S. B.
    Chakraborty, A.
    WEAR, 2008, 264 (11-12) : 1015 - 1025
  • [30] Microstructure tailoring to enhance strength and ductility in Ti-13Nb-13Zr for biomedical applications
    Lee, Taekyung
    Heo, Yoon-Uk
    Lee, Chong Soo
    SCRIPTA MATERIALIA, 2013, 69 (11-12) : 785 - 788