A ratiometric multicolor fluorescence biosensor for visual detection of alkaline phosphatase activity via a smartphone

被引:101
|
作者
Hou, Li [1 ]
Qin, Yuxin [1 ]
Li, Jinying [1 ]
Qin, Siyuan [1 ]
Huang, Yuanlin
Lin, Tianran [1 ]
Guo, Liangqia [2 ]
Ye, Fanggui [1 ]
Zhao, Shulin [1 ]
机构
[1] Guangxi Normal Univ, Coll Chem & Pharmaceut Sci, State Key Lab Chem & Mol Engn Med Resources, Guilin 541004, Peoples R China
[2] Fuzhou Univ, Coll Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Minist Educ,Key Lab Analyt Sci Food Safety & Biol, Fuzhou 350116, Fujian, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Multicolor fluorescent biosensor; Smartphone; Alkaline phosphatase; Visual detection; Metal organic framework; METAL-ORGANIC FRAMEWORKS; ASSAY; CONSTRUCTION; HYDROGELATION; NANOPARTICLES;
D O I
10.1016/j.bios.2019.111605
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Herein we designed a selective and smartphone-based strategy for visual detection of alkaline phosphatase (ALP) by utilizing the property of amino-functionalized copper (II)-based metal-organic frameworks (NH2-Cu-MOFs) with oxidase mimic property and fluorescence property. Surprisingly, the oxidase mimic property of NH2-Cu-MOFs can work well at a high pH value 8.0. Thus, a cascade reaction between ALP and NH2-Cu-MOFs was realized for the construction of a ratiometric multicolor sensing platform through the controllable catalytic activity of NH2-Cu-MOFs by pyrophosphate (PPi) and ALP. The catalytic activity of NH2-Cu-MOFs was greatly inhibited because of the binding ability of Cu2+ with PPi. When the ALP was added, the catalytic activity of NH2-Cu-MOFs was restored and then further catalyzed the o-phenylenediamine to form the 2, 3-diaminophenazine due to the hydrolysis function of ALP towards PPi into orthophosphates. RGB analysis of the fluorescent sample images was adopted for ALP quantitative analysis. Besides, a hydrogel test kit and mobile app for ALP detection were designed as conceptual products for point-of-care. The LODs of the fluorescence sensing platform was 0.078 mU mL(-1) and 0.35 mU mL(-1) by solution analysis and hydrogel test kit analysis, respectively. This fluorescent visual method was applied to ALP detection in serum samples with satisfying results, which opened a promising horizon for the diagnosis of other biomarkers in clinical serum samples based on ALP-mediated enzyme-linked immunosorbent assay for the development of biomedicine and clinical diagnosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A novel and sensitive ratiometric fluorescent quantum dot-based biosensor for alkaline phosphatase detection in biological samples via the inner-filter effect
    Hu, Penghui
    Huang, Ruiyan
    Xu, Ye
    Li, Tengfei
    Yin, Jun
    Yang, Yu
    Liang, Yuan
    Mao, Xiaohan
    Ding, Li
    Shu, Chang
    RSC ADVANCES, 2023, 13 (04) : 2311 - 2317
  • [32] ZIF-8@GMP-Tb nanocomplex for ratiometric fluorescent detection of alkaline phosphatase activity
    Ling, Yu
    He, Lin Zhao
    Wan, Chu Chu
    Han, Lei
    Wang, Xiao Hu
    Xu, Zi Yi
    Li, Xiao Lin
    Li, Nian Bing
    Luo, Hong Qun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 264
  • [33] Lanthanide doped metal-organic frameworks as a ratiometric fluorescence biosensor for visual and ultrasensitive detection of serotonin
    Song, Lijun
    Tian, Fuli
    Liu, Zhiliang
    JOURNAL OF SOLID STATE CHEMISTRY, 2022, 312
  • [34] Switch-conversional ratiometric fluorescence biosensor for miRNA detection
    Chen, Xian
    Xu, Ke
    Li, Jing
    Yang, Ming
    Li, Xing
    Chen, Qin
    Lu, Chunhua
    Yang, Huanghao
    BIOSENSORS & BIOELECTRONICS, 2020, 155
  • [35] Fluorescence detection of alkaline phosphatase activity with β-cyclodextrin-modified quantum dots
    Jia, Lan
    Xu, Jian-Ping
    Li, Di
    Pang, Shao-Peng
    Fang, Yuan
    Song, Zhe-Gang
    Ji, Jian
    CHEMICAL COMMUNICATIONS, 2010, 46 (38) : 7166 - 7168
  • [36] CDs-MnO2-TPPS Ternary System for Ratiometric Fluorescence Detection of Ascorbic Acid and Alkaline Phosphatase
    Lu, Hongzhi
    Xu, Shoufang
    ACS OMEGA, 2021, 6 (25): : 16565 - 16572
  • [37] Recent progress and prospects of alkaline phosphatase biosensor based on fluorescence strategy
    Han, Yangxia
    Chen, Jia
    Li, Zhan
    Chen, Hongli
    Qiu, Hongdeng
    BIOSENSORS & BIOELECTRONICS, 2020, 148
  • [38] Rapid and On-Site Detection of Uranyl Ions via Ratiometric Fluorescence Signals Based on a Smartphone Platform
    Chen, Xinfeng
    Mei, Qingsong
    Yu, Long
    Ge, Hongwei
    Yue, Ji
    Zhang, Kui
    Hayat, Tasawar
    Alsaedi, Ahmed
    Wang, Suhua
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (49) : 42225 - 42232
  • [39] A ratiometric fluorescence method based on nitrogen-doped carbon quantum dots for the determination of the activity of alkaline phosphatase
    Lv, Yuntai
    Chen, Junyang
    Zhou, Xiaobin
    Su, Xingguang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (28) : 7989 - 7998
  • [40] A ratiometric fluorescence method based on nitrogen-doped carbon quantum dots for the determination of the activity of alkaline phosphatase
    Yuntai Lv
    Junyang Chen
    Xiaobin Zhou
    Xingguang Su
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7989 - 7998