Use of sponge iron dosing in baffled subsurface-flow constructed wetlands for treatment of wastewater treatment plant effluents during autumn and winter

被引:3
|
作者
Feng, Muyu [1 ,2 ]
Liang, Jinming [1 ,2 ]
Wang, Peng [1 ,2 ]
Wang, Ya'e [1 ,2 ]
Li, Jie [1 ,2 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Environm & Municipal Engn, Lanzhou 730070, Peoples R China
[2] Key Lab Yellow River Water Environm Gansu Prov, Lanzhou, Peoples R China
关键词
Autotrophic denitrification; BSFCW; low temperature; sponge iron; wastewater treatment plant effluents; ZERO-VALENT IRON; NITROGEN REMOVAL; NITRATE REDUCTION; PHOSPHORUS RELEASE; OXIDATION PROCESS; CARBON SOURCE; TAIL-WATER; PERFORMANCE; ANAMMOX; DENITRIFICATION;
D O I
10.1080/15226514.2022.2031866
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sponge iron (SI) is widely used in water treatment. As effluents from wastewater treatment plant (WWTP) require advanced treatment methodology, three forms of constructed wetlands (CWs): wetlands with sponge iron (SI), copper sulfate modified sponge iron (Cu/SI), and sponge iron coupled with solid carbon sources (C/SI), have been investigated in this paper for the removal effects of organic matter and nutrients in WWTP effluents, and the corresponding mechanisms have been analyzed. The results showed the effect of baffled subsurface-flow constructed wetland (BSFCW) with SI dosing to purify the WWTP effluents after the stable operation. The water flow of this BSFCW is the repeated combination of upward flow and downward flow, which can provide a longer treatment pathway and microbial exposure time. The average removal rates of total inorganic nitrogen (TIN) were 27.80%, 30.17%, and 44.83%, and the average removal rates of chemical oxygen demand (COD) were 19.96%, 23.73%, and 18.38%. The average removal rates of total phosphorus (TP) were 85.94%, 82.14%, and 83.95%. Cu/SI improved the dissolution of iron, C/SI improved denitrification, and a winter indoor temperature retention measure was adopted to increase the effectiveness of wetland treatment during the winter months. After comprehensively analyzing X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and two-dimensional numerical simulation diagrams, a plausible conjecture that microbes use electrons from SI for autotrophic denitrification is presented. Moreover, the stress effect of wetlands dosed with SI on plants decreased stepwise along the course since C/SI used on wetlands had less impact on plant stress. NOVELTY STATEMENT 1. Treatment of sequencing batch biofilm reactor reaction effluent indoors in low temperature using a combination of three wetland fillers, sponge iron + gravel, copper sulfate modified sponge iron + gravel, and sponge iron coupled carbon source + gravel. 2. The use of the baffled subsurface-flow constructed wetland, combined with the distribution simulation diagram, especially the distribution simulation diagram of iron, gives an explanation to the degradation mechanism of the pollutants and the transformation of iron into wetlands. 3. An conjecture of electron transport during microbial autotrophic denitrification involving iron is presented, plausibly explaining the variation in treatment effects.
引用
收藏
页码:1405 / 1417
页数:13
相关论文
共 50 条
  • [31] Comparison of operational design criteria for subsurface flow constructed wetlands for wastewater treatment
    Leonard, KM
    Swanson, GW
    WATER SCIENCE AND TECHNOLOGY, 2001, 43 (11) : 301 - 307
  • [32] Comparison of first-order kinetic models for sewage treatment in horizontal subsurface-flow constructed wetlands
    Ferreira, Aline Gomes
    Borges, Alisson Carraro
    Rosa, Andre Pereira
    ENVIRONMENTAL TECHNOLOGY, 2021, 42 (28) : 4511 - 4518
  • [33] Performance of pilot-scale horizontal subsurface flow constructed wetlands in wastewater treatment
    Akratos, C. S.
    Tsihrintzis, V. A.
    Papaspyros, J. N. E.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL A - ORAL PRESENTATIONS, PTS A AND B, 2005, : A38 - A43
  • [34] Considerations on design and implementation parameters of domestic wastewater treatment by subsurface flow constructed wetlands
    Athaydes Fadanelli, Lis Eveline
    de Andrade Filho, Alceu Gomes
    Wiecheteck, Giovana Katie
    Ribas Doll, Maria Magdalena
    ENGENHARIA SANITARIA E AMBIENTAL, 2019, 24 (04) : 809 - 819
  • [35] Evaluating wastewater treatment efficiency of two field scale subsurface flow constructed wetlands
    Tilak, A. S.
    Wani, S. P.
    Patil, M. D.
    Datta, A.
    CURRENT SCIENCE, 2016, 110 (09): : 1764 - 1772
  • [36] Treatment of domestic wastewater in tropical, subsurface flow constructed wetlands planted with Canna and Heliconia
    Konnerup, Dennis
    Koottatep, Thammarat
    Brix, Hans
    ECOLOGICAL ENGINEERING, 2009, 35 (02) : 248 - 257
  • [37] Series Type Vertical Subsurface Flow Constructed Wetlands for Dairy Farm Wastewater Treatment
    Galve, Julius Cezar A.
    Sundo, Marloe B.
    Camus, Donny Rey D.
    De Padua, Victor Mikael N.
    Morales, Richard Dean F.
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2021, 7 (02): : 292 - 303
  • [38] Hybrid constructed wetlands for highly polluted river water treatment and comparison of surface-and subsurface-flow cells
    Yucong Zheng
    Xiaochang Wang
    Jiaqing Xiong
    Yongjun Liu
    Yaqian Zhao
    Journal of Environmental Sciences , 2014, (04) : 749 - 756
  • [39] Hybrid constructed wetlands for highly polluted river water treatment and comparison of surface-and subsurface-flow cells
    Yucong Zheng
    Xiaochang Wang
    Jiaqing Xiong
    Yongjun Liu
    Yaqian Zhao
    Journal of Environmental Sciences, 2014, 26 (04) : 749 - 756
  • [40] REVIEW PAPER ON HORIZONTAL SUBSURFACE FLOW CONSTRUCTED WETLANDS: POTENTIAL FOR THEIR USE IN CLIMATE CHANGE MITIGATION AND TREATMENT OF WASTEWATER
    Engida, T.
    Wu, J. M.
    Xu, D.
    Wu, Z. B.
    APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2020, 18 (01): : 1051 - 1089