Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation

被引:59
|
作者
Lee, Sun-Ho [1 ]
Kim, Eun Sang [1 ]
Sung, Joo-Kyung [2 ]
Park, Yeun-Mook [2 ]
Eoh, Whan [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Neurosurg, Samsung Med Ctr, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Neurosurg, Taegu, South Korea
关键词
Atlantoaxial; Fixation; Harms technique; Instability; Transarticular screw; POLYAXIAL SCREW; TECHNICAL NOTE; FUSION; COMPLEX; STABILIZATION; ARTHRODESIS; SUITABILITY; SUBLUXATION; EXPERIENCE; GRAFT;
D O I
10.1016/j.jocn.2009.10.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the clinical and radiological results of posterior atlantoaxial fixation surgery using transarticular screws to those using a polyaxial screw-rod system in 55 patients with symptomatic atlantoaxial instability Patients underwent posterior C1-C2 fixation 28 patients (group 1) underwent C1-C2 transarticular screw fixation and 27 patients (group 2) underwent C1 lateral mass-C2 pedicle screw fixation Patients were followed-up for at least 24 months The clinical and radiological results were evaluated in the early postoperative period and at 3, 6, 12 and 24 months after surgery Long-term postoperative stability and bone fusion were examined After surgery, 93% of patients in group 1 and 96% of patients in group 2 were free of neck pain The solid fusion rates were 82% for group 1 patients and 96% for group 2 patients at 12 months (p < 0.092) In group 1, three patients showed fibrous union Four patients had hardware failure due to a screw malposition (one in group 1) and pseudoarthrodesis (two in group 1 and one in group 2) One patient in group 1 had cerebrospinal fluid leakage One patient in group 2 had occipital neuralgia One vertebral artery injury occurred during the screw placement in group 1 and another in group 2 during the muscle dissection C1-C2 transarticular screw fixation and C1 lateral mass-C2 pedicle screw fixation both produced excellent results for stabilization of the atlantoaxial complex, but the radiological outcome tended to be superior in C1 lateral mass-C2 pedicle screw fixation (C) 2009 Elsevier Ltd All rights reserved
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [21] C1-c2 transarticular screw fixation for atlantoaxial instability: A 6-year experience - In reply
    Subach, BR
    Haid, RW
    Rodts, GE
    NEUROSURGERY, 2002, 50 (03) : 673 - 673
  • [22] Computer-assisted C1-C2 Transarticular Screw Fixation "Magerl Technique" for Atlantoaxial Instability
    Uehara, Masashi
    Takahashi, Jun
    Hirabayashi, Hiroki
    Hashidate, Hiroyuki
    Ogihara, Nobuhide
    Mukaiyama, Keijiro
    Kato, Hiroyuki
    ASIAN SPINE JOURNAL, 2012, 6 (03) : 168 - 177
  • [24] Clinical outcome of posterior C1-C2 pedicle screw fixation and fusion for atlantoaxial instability: A retrospective study of 86 patients
    Zheng, Yonghong
    Hao, Dingjun
    Wang, Biao
    He, Baorong
    Hu, Huimin
    Zhang, Haiping
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 32 : 47 - 50
  • [25] C1-c2 transarticular screw fixation: Technical aspects
    Haid, RW
    NEUROSURGERY, 2001, 49 (01) : 71 - 74
  • [26] Clinical outcome of posterior fixation of the C1 lateral mass and C2 pedicle by polyaxial screw and rod
    Jeon, Sei Woong
    Jeong, Je Noon
    Choi, Gi Hoon
    Moon, Seung Myung
    Hwang, Hyung Sik
    Choi, Sun Kil
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2012, 114 (06) : 539 - 544
  • [27] Evaluation of the Efficacy of Titanium Mesh Cages with Posterior C1 Lateral Mass and C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Yi, Hyoung-Joong
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2016, 90 : 103 - 108
  • [28] Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability
    Isik, Hasan Serdar
    Sandal, Evren
    Cagli, Sedat
    TURKISH NEUROSURGERY, 2018, 28 (04) : 602 - 609
  • [29] Three-point atlantoaxial fixation with C1-C2 transarticular screws and C1 lateral mass screws
    Harati, Ali
    Oni, Paul
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [30] Atlantoaxial arthrodesis using C1-C2 transarticular screw fixation in a case of Morquio syndrome
    Arvind G. Kulkarni
    Siddharth M. Shah
    Indian Journal of Orthopaedics, 2011, 45 : 470 - 472