Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction

被引:0
|
作者
Cañero, C
Nofrerías, E
Mauri, J
Radeva, P
机构
[1] UAB, Comp Vis Ctr, Cerdanyola Del Valles 08190, Spain
[2] Univ Autonoma Barcelona, Dept Comp Sci, E-08193 Barcelona, Spain
[3] Hosp Univ Germans Tries & Pujol, Badalona, Spain
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper is concerned with the calibration of the intrinsic and extrinsic parameters of a X-ray angiographic system for 3D reconstruction of coronary vessel centerlines. We discuss whether the isocentric model is an accurate model for the movement of the C-arm, and analyse the assumptions made by this model. We propose a methodology which takes into account these facts and we propose for each model a calibration method. The calibration only needs a phantom that is commonly available by the physicians, since it is used to calibrate geometrical distortion. Then, we test the models with the calibration grid, as well as with a phantom imaged three months later. Experimental results show that by using the proposed models, it is not necessary neither a calibration nor a refinement at each acquisition.
引用
收藏
页码:322 / 335
页数:14
相关论文
共 50 条
  • [21] Online C-arm calibration using a marked guide wire for 3D reconstruction of pulmonary arteries
    Vachon, Etienne
    Miro, Joaquim
    Duong, Luc
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [22] Low contrast 3D-reconstruction from C-arm data
    Zellerhoff, M
    Scholz, B
    Rührnschopf, EP
    Brunner, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 646 - 655
  • [23] A method for extracting 3D information of cylinder in C-arm image
    Wu, Jian
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 544 - +
  • [24] 3D-Rotational Angiography: First clinical application with use of a standard Philips C-arm system
    Kemkers, R
    Op de Beek, J
    Aerts, H
    Koppe, R
    Klotz, E
    Grass, M
    Moret, J
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 182 - 187
  • [25] Intraoperative 3D C-arm imaging. State of the art
    von Recum, J.
    Wendl, K.
    Vock, B.
    Gruetzner, P. A.
    Franke, J.
    UNFALLCHIRURG, 2012, 115 (03): : 196 - 201
  • [26] 3-D geometry calibration and markerless electromagnetic tracking with a mobile C-arm
    Cheryauka, Arvi
    Barrett, Johnny
    Wang, Zhonghua
    Litvin, Andrew
    Hamadeh, Ali
    Beaudet, Daniel
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [27] C-arm CT soft tissue 3-D imaging with a mobile C-arm
    Ritter, D
    Mitschke, M
    Graumann, R
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 3 - 6
  • [28] 3D Robotic Catheter Shape Reconstruction and Localisation Using Appearance Priors and Adaptive C-Arm Positioning
    Vandini, Alessandro
    Giannarou, Stamatia
    Lee, Su-Lin
    Yang, Guang-Zhong
    AUGMENTED REALITY ENVIRONMENTS FOR MEDICAL IMAGING AND COMPUTER-ASSISTED INTERVENTIONS, 2013, 8090 : 172 - 181
  • [29] Exact 3D cone-beam reconstruction from two short-scans using a C-arm imaging system
    Ramamurthi, K
    Strobel, N
    Prince, JL
    COMPUTATIONAL IMAGING III, 2005, 5674 : 87 - 98
  • [30] 3D C-Arm Conebeam CT Angiography as an Adjunct in the Precise Anatomic Characterization of Spinal Dural Arteriovenous Fistulas
    Aadland, T. D.
    Thielen, K. R.
    Kaufmann, T. J.
    Morris, J. M.
    Lanzino, G.
    Kallmes, D. F.
    Schueler, B. A.
    Cloft, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (03) : 476 - 480