Optic Disc Morphology in Open-Angle Glaucoma Compared with Anterior Ischemic Optic Neuropathies

被引:56
|
作者
Danesh-Meyer, Helen V. [1 ]
Boland, Michael V. [2 ]
Savino, Peter J. [3 ]
Miller, Neil R. [2 ]
Subramanian, Prem S. [2 ]
Girkin, Christopher A. [4 ]
Quigley, Harry A. [2 ]
机构
[1] Univ Auckland, Dept Ophthalmol, New Zealand Natl Eye Ctr, Auckland 1020, New Zealand
[2] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[3] Thomas Jefferson Med Sch, Wilmer Eye Inst, Philadelphia, PA USA
[4] Univ Alabama Birmingham, Dept Ophthalmol, Birmingham, AL 35294 USA
基金
美国国家卫生研究院;
关键词
FIBER LAYER THICKNESS; LAMINA-CRIBROSA; VISUAL-FIELD; NERVE HEAD; PREVALENCE; TOPOGRAPHY; SIZE; EYES;
D O I
10.1167/iovs.09-3492
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare optic disc topography performed by confocal laser ophthalmoscopy in eyes with nonarteritic anterior ischemic optic neuropathy (NAION), arteritic anterior ischemic optic neuropathy (AAION), and open-angle glaucoma (OAG), adjusting for the amount of retinal ganglion cell (RGC) loss, as measured by nerve fiber layer (NFL) thickness and average visual field loss. METHODS. At four referral centers, patients who met specific diagnostic criteria for OAG (103 persons, 152 eyes), NAION (53 persons, 57 eyes), or AAION (18 persons, 20 eyes) underwent Heidelberg Retinal Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany), Stratus Optical Coherence Tomography (OCT; Carl Zeiss Meditec, Inc., Dublin, CA), and Humphrey visual field testing (HFA; Carl Zeiss Meditec, Inc.). HRT parameters were compared in univariate and multivariate models, accounting for degree of RGC loss by either OCT NFL thickness or visual field mean deviation (MD). Acute AION occurred at least 6 weeks before testing. RESULTS. After adjustment for degree of injury according to either MD or mean NFL thickness, all HRT parameters were significantly different between OAG and both NAION and AAION. With similar damage, OAG eyes had larger, deeper cups; smaller rims; more cup volume; and less rim volume (all P <= 0.001). There were differences in disc topography between NAION and AAION, but they were not consistent for both measures of damage. Disc area and MD were also significantly associated with many HRT parameters. NFL thickness was greater at the same MD for both AAION and NAION compared with OAG. CONCLUSIONS. NAION and AAION cause loss of RGCs, but have significantly different disc topography compared with OAG at a given level of RGC loss. (Invest Ophthalmol Vis Sci. 2010; 51: 2003-2010) DOI:10.1167/iovs.09-3492
引用
收藏
页码:2003 / 2010
页数:8
相关论文
共 50 条
  • [31] MEASUREMENT OF OPTIC DISC AREA AND ITS CLINICAL RELEVANCE IN OPEN-ANGLE GLAUCOMA
    NANGIA, V
    SCHWARTZ, B
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (03) : 255 - 262
  • [32] Different types of optic disc shape in patients with advanced open-angle glaucoma
    Toru Nakazawa
    Nobuo Fuse
    Kazuko Omodaka
    Naoko Aizawa
    Souichiro Kuwahara
    Kohji Nishida
    Japanese Journal of Ophthalmology, 2010, 54 : 291 - 295
  • [33] Optic Disc Fluorescein Leakage and Intraocular Pressure in Primary Open-Angle Glaucoma
    Plange, Niklas
    Bienert, Marion
    Remky, Andreas
    Arend, Kay Oliver
    CURRENT EYE RESEARCH, 2012, 37 (06) : 508 - 512
  • [34] Pattern of peripapillary capillary density loss in ischemic optic neuropathy compared to that in primary open-angle glaucoma
    Fard, Masoud Aghsaei
    Suwan, Yanin
    Moghimi, Sasan
    Geyman, Lawrence S.
    Chui, Toco Y.
    Rosen, Richard B.
    Ritch, Robert
    PLOS ONE, 2018, 13 (01):
  • [35] Morphometric characteristics of optic disc in patients with myopia and primary open-angle glaucoma
    Gvozdenovic, Ranko
    Risovic, Dusica
    Marjanovic, Ivan
    Vukovic, Dragan
    Stankovic, Branislav
    VOJNOSANITETSKI PREGLED, 2013, 70 (01) : 51 - 56
  • [36] Fluorescein leakage of the optic disc: Time course in primary open-angle glaucoma
    Plange, N
    Kaup, M
    Doehmen, B
    Remky, A
    Arend, O
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [37] Retrobulbar haemodynamics and morphometric optic disc analysis in primary open-angle glaucoma
    Plange, N.
    Kaup, M.
    Weber, A.
    Arend, K. O.
    Remky, A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) : 1501 - 1504
  • [38] Visual Field Progression Pattern Associated With IQ Optic Disc Tilt Morphology in Myopic Open-Angle Glaucoma
    Han, Jong Chul
    Lee, Eun Jung
    Kim, Seung Hoon
    Kee, Changwon
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 : 33 - 45
  • [39] Variations in optic nerve head morphology by intraocular pressure in open-angle glaucoma
    Aaron Wong
    Kaliopy Matheos
    Zak Prime
    Helen V. Danesh-Meyer
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 2219 - 2226
  • [40] Variations in optic nerve head morphology by intraocular pressure in open-angle glaucoma
    Wong, Aaron
    Matheos, Kaliopy
    Prime, Zak
    Danesh-Meyer, Helen V.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (11) : 2219 - 2226