A novel ultrasonic strain gauge for single-sided measurement of a local 3D strain field

被引:7
|
作者
Kersemans, Mathias [1 ]
Allaer, Klaas [1 ]
Van Paepegem, Wim [1 ]
Van den Abeele, Koen [2 ]
Pyl, Lincy [3 ]
Zastavnik, Filip [3 ]
Sol, Hugo [3 ]
Degrieck, Joris [1 ]
机构
[1] Univ Ghent, Dept Mat Sci & Engn, B-9052 Zwijnaarde, Belgium
[2] Catholic Univ Leuven KULAK, Dept Phys, B-8500 Kortrijk, Belgium
[3] Vrije Univ Brussel, Dept Mech Mat & Construct, B-1050 Brussels, Belgium
关键词
Ultrasound; Local 3D strain measurement; DC06; steel; Lankford ratio; LARGE PLASTIC-DEFORMATION; FRACTURE RESPONSE; ANOMALIES;
D O I
10.1007/s11340-014-9953-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel method is introduced for the measurement of a 3D strain field by exploiting the interaction between ultrasound waves and geometrical characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incident pulsed waves in frequency domain provides a measure of the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed ultrasonic strain gauge yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are needless. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2 % up to 35 %. The ultrasonically measured strains have been validated with various other strain measurement techniques, including manual micrometer, longitudinal and transverse mechanical extensometer and optical mono- and stereovision digital image correlation. Good agreement has been obtained between the ultrasonically determined strain values and the results of the conventional methods. As the ultrasonic strain gauge provides all three normal strain field components, it has been employed for the extraction of Lankford ratios at different applied longitudinal plastic strain levels, revealing a strain dependent plastic anisotropy of the investigated DC06 steel sheet.
引用
收藏
页码:1673 / 1685
页数:13
相关论文
共 50 条
  • [21] Contrast-enhanced echocardiography in 3D strain measurement
    Paakkanen, R.
    He, A.
    Paterson, I.
    Pituskin, E.
    Mirhadi, E.
    Choy, J.
    Mackey, J.
    Becher, H.
    EUROPEAN HEART JOURNAL, 2016, 37 : 656 - 656
  • [22] Strain Measurement Using 3D Stereo Image Correlation
    Kumari, Gitanjali
    Banik, Sunanda
    Premi, M. S. Godwin
    2015 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION, EMBEDDED AND COMMUNICATION SYSTEMS (ICIIECS), 2015,
  • [23] Laser test studies on the single-sided dual-column 3D stripixelsilicon detector
    Liu, Shuhuan
    Li, Zheng
    Chen, Wei
    Montalbano, A.
    Xu, Hao
    Li, Shaorui
    Cui, Yonggang
    FUSION ENGINEERING AND DESIGN, 2017, 125 : 615 - 624
  • [24] Single-sided Multi-layer Electric Circuit by Hot Stamping with 3D Printer
    Imai, Yuhei
    Manabe, Hiroyuki
    ADJUNCT PROCEEDINGS OF THE 34TH ANNUAL ACM SYMPOSIUM ON USER INTERFACE SOFTWARE AND TECHNOLOGY, UIST 2021, 2021, : 126 - 128
  • [25] Optical measurement of the dynamic strain field of a fan blade using a 3D scanning vibrometer
    Vuye, C.
    Vanlanduit, S.
    Presezniak, F.
    Steenackers, G.
    Guillaume, P.
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (07) : 988 - 997
  • [26] CB/PDMS Based Strain Gauge Using 3D Printed Mold
    Liu, B.
    Bose, A. K.
    Zhang, X.
    Zhang, Z.
    2021 IEEE INTERNATIONAL CONFERENCE ON ELECTRO INFORMATION TECHNOLOGY (EIT), 2021, : 197 - 201
  • [27] A Mohr circle method for 3D strain measurement using the geometry of no finite longitudinal strain and the RXZ strain ratio
    Sarkarinejad, Khalil
    Samani, Babak
    Faghih, Ali
    JOURNAL OF STRUCTURAL GEOLOGY, 2011, 33 (04) : 424 - 432
  • [28] Three-dimensional strain imaging and related strain artifacts using an ultrasonic 3D abdominal probe
    Lorenz, A
    Pesavento, A
    Pesavento, M
    Ermert, H
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1657 - 1660
  • [29] 3D-strain field measurement of parallelepipedal tensile specimen
    Gründer, KP
    Geburtig, A
    TECHNISCHES MESSEN, 2002, 69 (10): : 418 - 420
  • [30] Line strain representation and shear strain representation of 3D strain states
    Li, Shunqun
    Cheng, Xuelei
    Fu, Jianbao
    Pan, Lin
    Hai, Ran
    PLOS ONE, 2021, 16 (11):