Characterization of the Response of Active Detectors and Passive Dosemeters Used for Dose Measurement in Small Photon Beams

被引:5
|
作者
Derreumaux, S.
Bassinet, C.
Huet, C.
Chea, M.
Boisserie, G.
Brunet, G.
Baumann, M.
Trompier, F.
Roch, P.
Clairand, I.
机构
关键词
D O I
10.1118/1.3612113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-163
引用
收藏
页码:3523 / U124
页数:2
相关论文
共 50 条
  • [21] Dose response of alanine detectors irradiated with carbon ion beams
    Herrmann, Rochus
    Jaekel, Oliver
    Palmans, Hugo
    Sharpe, Peter
    Bassler, Niels
    MEDICAL PHYSICS, 2011, 38 (04) : 1859 - 1866
  • [22] Determination of Output Factors with Different Types of Active Detectors and Passive Dosemeters for Stereotactic Systems Equipped with MicroMLC and Circular Cones
    Bassinet, C.
    Huet, C.
    Derreumaux, S.
    Brunet, G.
    Chea, M.
    Baumann, M.
    Trompier, F.
    Roch, P.
    Boisserie, G.
    Clairand, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [23] Bias dependance of the response of superconducting tunnel junctions used as photon detectors
    Poelaert, A
    den Hartog, R
    Peacock, A
    Kozorezov, A
    Wigmore, JK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 442 (1-3): : 275 - 278
  • [24] Recent developments of passive and active detectors used in the monitoring of external environmental radiation
    Sáez-Vergara, JC
    RADIATION PROTECTION DOSIMETRY, 2000, 92 (1-3) : 83 - 88
  • [25] Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations
    Wang, Lilie L. W.
    Beddar, Sam
    MEDICAL PHYSICS, 2011, 38 (03) : 1596 - 1599
  • [26] Characterization of Optically-Stimulated Luminescent Detectors (OSLDs) in Photon & Proton Beams
    Kerns, J.
    Ibbott, G.
    Johnson, V.
    Kry, S.
    Sahoo, N.
    Followill, D.
    MEDICAL PHYSICS, 2010, 37 (06) : 3452 - +
  • [27] Emulsion detectors for dose distribution characterization in the halo of proton pencil beams
    Braccini, S.
    Ariga, A.
    Ariga, T.
    Ereditato, A.
    Giacoppo, F.
    Nesteruk, K. P.
    Pistillo, C.
    Scampoli, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (01) : 87 - 87
  • [28] Characterization of small active detectors for electronic brachytherapy dosimetry
    Yip, F. Garcia
    Schneider, T.
    Reginatto, M.
    Behrens, R.
    Buermann, L.
    Grote, F.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (03):
  • [29] Investigating the lateral dose response functions of point detectors in proton beams
    Kretschmer, Jana
    Brodbek, Leonie
    Looe, Hui Khee
    van der Graaf, Emiel
    van Goethem, Marc Jan
    Kiewiet, Harry
    Olivari, Francesco
    Meyer, Christoph
    Poppe, Bjoern
    Brandenburg, Sytze
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [30] Characterization of small active detectors for electronic brachytherapy dosimetry
    Yip, F. Garcia
    Schneider, T.
    Reginatto, M.
    Behrens, R.
    Buermann, L.
    Grote, F.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S98 - S100