Comparison of the accuracies of two methods for the determination of the surface normal for X-ray photoelectron spectroscopy

被引:2
|
作者
Seah, M. P. [1 ]
机构
[1] Natl Phys Lab, Div Qual Life, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1088/0026-1394/44/3/011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Determining the true angle of detection of emitted electrons is a major factor for the accurate determination of film thicknesses in the range below 10 nm by x- ray photoelectron spectroscopy. To do this, the orientation of the surface normal in the instrument first requires determination. A comparison is made of two recent methods for the definition of the surface normal in x- ray photoelectron spectrometers. The first method, which we call the crystal axis method, involves the measurement of the Si 2p oxide and substrate intensities in the range +/- 5 degrees around the surface normal for a (100) Si wafer with approximately 1 nm of thermal oxide. The second method, which we call the overlayer thickness consistency method, involves measuring similar intensities at 10 degrees, 20 degrees, 30 degrees and 40 degrees from the surface normal, for an amorphous oxide on amorphous Si sample, with a view to obtaining a consistent thickness. It is shown that both can readily define the surface normal alignment better than 1 degrees but that the crystal axis method, for similar data quality and numbers of spectra, generates uncertainties a factor of approximately three times better than that of the overlayer consistency method and has fewer bias contributions. Possible improvements in the method are shown to be best by recording more data in the crystal axis method rather than, for example, by changing the materials.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 50 条
  • [41] Surface Analysis of Nanocomplexes by X-ray Photoelectron Spectroscopy (XPS)
    Korin, Efrat
    Froumin, Natalya
    Cohen, Smadar
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2017, 3 (06): : 882 - 889
  • [42] X-RAY PHOTOELECTRON-SPECTROSCOPY OF A DOPED SILICON SURFACE
    BUZANEVA, EV
    KOSTIKOV, YP
    STRIKHA, VI
    STRYKANOV, VS
    SHUSTROV, BA
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1981, 15 (02): : 155 - 158
  • [43] Algorithm for automatic x-ray photoelectron spectroscopy data processing and x-ray photoelectron spectroscopy imaging
    Tougaard, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2005, 23 (04): : 741 - 745
  • [44] X-ray photoelectron spectroscopy in the hard X-ray regime
    Fadley, C. S.
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2007, 156 : XXXVI - XXXVI
  • [45] Methionine by X-ray Photoelectron Spectroscopy
    Naval Surface Warfare Center, Carderock Division, West Bethesda
    MD
    20817-5700, United States
    Surf. Sci. Spectra, 1 (96-101):
  • [46] X-RAY PHOTOELECTRON-SPECTROSCOPY
    WATTS, JF
    VACUUM, 1994, 45 (6-7) : 653 - 671
  • [47] Introduction to x-ray photoelectron spectroscopy
    Stevie, Fred A.
    Donley, Carrie L.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2020, 38 (06):
  • [48] X-ray photoelectron spectroscopy of conodonts
    Leel, GSH
    Mar, GL
    Rose, HR
    Marshall, CP
    Young, BR
    Skilbeck, CG
    Wilson, MA
    ORGANIC GEOCHEMISTRY, 1998, 28 (11) : 759 - 765
  • [49] X-ray photoelectron spectroscopy of ferroelectrics
    Grigas, Jonas
    Talik, Ewa
    Lazauskas, Valentinas
    FERROELECTRICS, 2007, 347 : 86 - 100
  • [50] X-RAY PHOTOELECTRON-SPECTROSCOPY
    DOMEN, K