Measurements of pelvic flexion angle using three-dimensional computed tomography

被引:187
|
作者
Nishihara, S
Sugano, N
Nishii, T
Ohzono, K
Yoshikawa, H
机构
[1] Osaka Univ, Sch Med, Dept Orthopaed Surg, Osaka 5650871, Japan
[2] Osaka Natl Hosp, Dept Orthopaed Surg, Osaka, Japan
关键词
D O I
10.1097/01.blo.0000069891.31220.fd
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the current study was to evaluate whether safe acetabular component position depends on differences in pelvic location between the supine, standing, and sitting positions. The subjects of the current study were 101 patients who had total hip arthroplasty. Anteroposterior radiographs of the pelvis with the patients in the supine, standing, and sitting positions were obtained preoperatively and 1 year after total hip arthroplasty. Computed tomography images of the pelvis were obtained preoperatively. Using image matching between the three-dimensional computed tomography model and anteroposterior radiograph, pelvic flexion angles with the patient in the supine, standing, and sitting positions were calculated. The mean preoperative pelvic flexion angle was 5degrees +/- 9degrees (range, -37degrees-30degrees) in the supine position, 3degrees +/- 12degrees (range, -46degrees-33degrees) in the standing position, and -29degrees +/- 12degrees (range, -62degrees-10degrees) in the sitting position. Because there was much intersubject variability in pelvic flexion angle, it is not appropriate to determine orientation of the acetabular component from anatomic landmarks. In 90% of the cases, the difference in pelvic flexion angle between the supine and standing positions preoperatively was 10degrees or less. In 90% of the cases, there was 20degrees or greater extension of the pelvis from the supine position to the sitting position preoperatively, and the safe range of flexion of the hip from anterior prosthetic impingement in the sitting position was 20degrees or greater than that in the supine position. Preoperative pelvic position in each case was almost completely maintained 1 year after total hip arthroplasty. It is reasonable to regard the pelvic position in the supine position as the functional pelvic position and proper pelvic reference frame in determining optimal orientation of the acetabular component in 90% of cases before and 1 year after total hip arthroplasty, although an adjustment of orientation of the acetabular component was needed for the remaining cases.
引用
收藏
页码:140 / 151
页数:12
相关论文
共 50 条
  • [31] Three-Dimensional Computed Tomography of the Carpal Ligaments
    Nanno, Mitsuhiko
    Viegas, Steven F.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2009, 13 (01) : 3 - 17
  • [32] Anthropometric measurements of patellar ridge using computed tomography-based three-dimensional computer models
    Xiaoliang Mei
    Hao Ding
    Jia Meng
    Jianning Zhao
    Journal of Orthopaedic Surgery and Research, 16
  • [33] Three-dimensional computed tomography of the pulmonary veins
    Tada, H
    Oral, H
    Knight, BP
    Morady, F
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (05) : 521 - 521
  • [34] A comparison of two-dimensional radiography and three-dimensional computed tomography in angular cephalometric measurements
    Nalcaci, R.
    Ozturk, F.
    Sokucu, O.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) : 100 - 106
  • [35] Computed Tomography Measurements as a Standard of Exophthalmos? Two-Dimensional Versus Three-Dimensional Techniques
    Guo, Jie
    Qian, Jiang
    Yuan, Yifei
    CURRENT EYE RESEARCH, 2018, 43 (05) : 647 - 653
  • [36] Three-dimensional visualization of soil pore structure using computed tomography
    Han, Qiaoling
    Zhou, Xibo
    Liu, Lei
    Zhao, Yandong
    Zhao, Yue
    JOURNAL OF FORESTRY RESEARCH, 2019, 30 (03) : 1053 - 1061
  • [37] Three-dimensional alveolar bone morphology analysis using computed tomography
    Naito, T
    Hosokawa, R
    Yokota, M
    JOURNAL OF PERIODONTOLOGY, 1998, 69 (05) : 584 - 589
  • [38] Anatomical Studies of the Orbital Cavity Using Three-Dimensional Computed Tomography
    Kang, Hyo-Sun
    Han, Jeong Joon
    Oh, Hee-Kyun
    Kook, Min-Suk
    Jung, Seunggon
    Park, Hong-Ju
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (06) : 1583 - 1588
  • [39] Three-dimensional visualization of soil pore structure using computed tomography
    Qiaoling Han
    Xibo Zhou
    Lei Liu
    Yandong Zhao
    Yue Zhao
    Journal of Forestry Research, 2019, 30 : 1053 - 1061
  • [40] Terahertz computed tomography in three-dimensional using a pyroelectric array detector
    Li, Bin
    Wang, Dayong
    Zhou, Xun
    Rong, Lu
    Huang, Haochong
    Wan, Min
    Wang, Yunxin
    HOLOGRAPHY: ADVANCES AND MODERN TRENDS V, 2017, 10233