Rotational malalignment of the femoral component in total knee arthroplasty

被引:162
|
作者
Fehring, TK
机构
[1] Charlotte Orthoped Specialists Hip & Knee Ctr, Charlotte, NC USA
[2] Charlotte Orthoped Res Inst, Charlotte, NC USA
关键词
D O I
10.1097/00003086-200011000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ligamentous balancing is a crucial part of total knee arthroplasty, To ensure proper kinematics, balance must be achieved in flexion and extension. Failure to do so may result in limited range of motion, premature polyethylene wear, or patellofemoral tracking problems, Balancing in extension is dependent on the type and extent of correctional ligamentous release. Flexion balance is dependent on proper femoral rotation, There are two methods to determine femoral rotation, In the classic method, the knee is tensed in flexion after Ligamentous release in extension. The anteroposterior cut then is made parallel to the cut tibial surface. Alternatively, the anteroposterior cut can be based off fixed femoral landmarks, The purpose of the current study was to determine the variance between balancing the flexion gap with the classic method versus the technique of using fixed femoral landmarks to determine rotation, One hundred consecutive posterior stabilized knee arthroplasties were performed using the classic method, The resected posterior condyles in each case were measured, The actual difference between the resected condyles using the classic method was compared with the calculated difference of resected bone using bony landmarks to determine rotation. A variance analysis then was performed. Compared with classically balanced knees, rotational errors of at least 3 degrees occurred in 45% of patients when rotation was determined from fixed bony landmarks, These patients had trapezoidal rather than rectangular flexion gaps, Such errors may have implications regarding polyethylene wear, range of motion, and long-term clinical results.
引用
收藏
页码:72 / 79
页数:8
相关论文
共 50 条
  • [21] Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial
    Joon Kyu Lee
    Sahnghoon Lee
    Sae Hyung Chun
    Ki Tae Kim
    Myung Chul Lee
    BMC Musculoskeletal Disorders, 18
  • [22] Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial
    Lee, Joon Kyu
    Lee, Sahnghoon
    Chun, Sae Hyung
    Kim, Ki Tae
    Lee, Myung Chul
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [23] Fracture of femoral component in a resurfacing total knee arthroplasty
    Michos, John
    Rallis, John
    Fassoulas, Apostolos
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1068 - 1071
  • [24] Femoral Component Survival in Hybrid Total Knee Arthroplasty
    Perry, Clayton R.
    Perry, Kevin I.
    ORTHOPEDICS, 2016, 39 (03) : 181 - 186
  • [25] Femoral component rotation during total knee arthroplasty
    Olcott, CW
    Scott, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (367) : 39 - 42
  • [26] Femoral component failure in hybrid total knee arthroplasty
    Campbell, MD
    Duffy, GP
    Trousdale, RT
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 58 - 65
  • [27] FRACTURE OF THE FEMORAL COMPONENT IN CEMENTLESS TOTAL KNEE ARTHROPLASTY
    WHITESIDE, LA
    FOSCO, DR
    BROOKS, JG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (286) : 71 - 77
  • [28] Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty
    Daniel Hernandez-Vaquero
    Alfonso Noriega-Fernandez
    Jose Manuel Fernandez-Carreira
    Jose Manuel Fernandez-Simon
    Jimena Llorens de los Rios
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 3127 - 3134
  • [29] Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Manuel Fernandez-Carreira, Jose
    Manuel Fernandez-Simon, Jose
    Llorens de los Rios, Jimena
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3127 - 3134
  • [30] Intraoperative Measurements of Femoral Anterior Tangent (FAT) Line for Determining the Rotational Alignment of Femoral Component of Total Knee Arthroplasty
    Watanabe, Hiroki
    Gejo, Ryuichi
    Tokunaga, Ayano
    Hirano, Norikazu
    Kimura, Tomoatsu
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10): : 1757 - 1759