Measuring Spinal Mobility Using an Inertial Measurement Unit System: A Reliability Study in Axial Spondyloarthritis

被引:12
|
作者
O'Grady, Megan [1 ]
O'Dwyer, Tom [1 ]
Connolly, James [2 ]
Condell, Joan [3 ]
Esquivel, Karla Munoz [3 ]
O'Shea, Finbar D. [4 ]
Gardiner, Philip [5 ]
Wilson, Fiona [1 ]
机构
[1] Trinity Coll Dublin, Discipline Physiotherapy, Dublin D08 W9RT, Ireland
[2] Letterkenny Inst Technol, Letterkenny F92 FC93, Donegal, Ireland
[3] Ulster Univ, Fac Comp Engn & Built Environm, Intelligent Syst Res Ctr, Magee Campus, Derry BT48 7JL, Londonderry, North Ireland
[4] St James Hosp, Rheumatol Dept, Dublin D08 NHY1, Ireland
[5] Western Hlth & Social Care Trust, Derry BT47 6SB, Londonderry, North Ireland
关键词
axial spondyloarthritis; spinal mobility; inertial measurement unit; reliability; SPONDYLITIS METROLOGY INDEX; ANKYLOSING-SPONDYLITIS; CORRELATION-COEFFICIENTS; RHEUMATOID-ARTHRITIS; SELF-MANAGEMENT; BATH; MOTION;
D O I
10.3390/diagnostics11030490
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objectives of this study were to evaluate the reliability of wearable inertial motion unit (IMU) sensors in measuring spinal range of motion under supervised and unsupervised conditions in both laboratory and ambulatory settings. A secondary aim of the study was to evaluate the reliability of composite IMU metrology scores (IMU-ASMI (Amb)). Forty people with axSpA participated in this clinical measurement study. Participant spinal mobility was assessed by conventional metrology (Bath Ankylosing Spondylitis Metrology Index, linear version-BASMI(Lin)) and by a wireless IMU sensor-based system which measured lumbar flexion-extension, lateral flexion and rotation. Each sensor-based movement test was converted to a normalized index and used to calculate IMU-ASMI (Amb) scores. Test-retest reliability was evaluated using intra-class correlation coefficients (ICC). There was good to excellent agreement for all spinal range of movements (ICC > 0.85) and IMU-ASMI (Amb) scores (ICC > 0.87) across all conditions. Correlations between IMU-ASMI (Amb) scores and conventional metrology were strong (Pearson correlation >= 0.85). An IMU sensor-based system is a reliable way of measuring spinal lumbar mobility in axSpA under supervised and unsupervised conditions. While not a replacement for established clinical measures, composite IMU-ASMI (Amb) scores may be reliably used as a proxy measure of spinal mobility.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Respiration detection using Inertial Measurement Unit
    Itou, Satoshi
    Inoue, Shoshi
    Washino, Kaei
    2019 INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND ELECTRONICS ENGINEERING (ISEE 2019), 2019, : 119 - 123
  • [42] A Wearable System Based on Multiple Magnetic and Inertial Measurement Units for Spine Mobility Assessment: A Reliability Study for the Evaluation of Ankylosing Spondylitis
    Martinez-Hernandez, Adriana
    Perez-Lomeli, Juan S.
    Burgos-Vargas, Ruben
    Padilla-Castaneda, Miguel A.
    SENSORS, 2022, 22 (04)
  • [43] Localization of iRobot Create using inertial measuring unit
    Guran, Matej
    Fico, Tomas
    Chovancova, Anezka
    Duchon, Frantisek
    Hubinsky, Peter
    Dubravsky, Jozef
    2014 23RD INTERNATIONAL CONFERENCE ON ROBOTICS IN ALPE-ADRIA-DANUBE REGION (RAAD), 2014,
  • [44] Reliability and Validity of a Posture Matching Method Using Inertial Measurement Unit-Based Motion Tracking System for Construction Jobs
    Lee, Wonil
    Lin, Jia-Hua
    Bao, Stephen
    Lin, Ken-Yu
    COMPUTING IN CIVIL ENGINEERING 2019: DATA, SENSING, AND ANALYTICS, 2019, : 589 - 597
  • [45] Initial calibration of an inertial measurement unit using an optical position tracking system
    Kim, A
    Golnaraghi, MF
    PLANS 2004: POSITION LOCATION AND NAVIGATION SYMPOSIUM, 2004, : 96 - 101
  • [46] Assessment of Breathing Parameters Using an Inertial Measurement Unit (IMU)-Based System
    Cesareo, Ambra
    Previtali, Ylenia
    Biffi, Emilia
    Aliverti, Andrea
    SENSORS, 2019, 19 (01)
  • [47] Visual odometry system using multiple stereo cameras and inertial measurement unit
    Oskiper, Taragay
    Zhu, Zhiwei
    Samarasekera, Supun
    Kumar, Rakesh
    2007 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-8, 2007, : 899 - +
  • [48] Inspection System for Automatic Measurement of Level Differences in Belt Conveyors Using Inertial Measurement Unit
    Yasutomi, Andre Yuji
    Enoki, Hideo
    Yamaguchi, Shigeki
    Tamura, Kazuma
    2018 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2018, : 6155 - 6161
  • [49] Indoor-localization system using a Micro Inertial Measurement Unit (IMU)
    Hoeflinger, Fabian
    Zhang, Rui
    Reindl, Leonhard M.
    2012 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2012, : 443 - 447
  • [50] Reliability analysis of spherical six axis redundant inertial measurement unit
    Xu, Jintao
    Tian, Ailing
    THIRD INTERNATIONAL CONFERENCE ON SENSORS AND INFORMATION TECHNOLOGY, ICSI 2023, 2023, 12699