Evaluation of high density DRAMs as a nuclear radiation detector

被引:2
|
作者
Chou, HP [1 ]
Chou, TC [1 ]
Hau, TH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Engn, Hsinchu 300, Taiwan
关键词
D O I
10.1016/S0969-8043(97)00160-7
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The research is based on the nuclear radiation induced soft error phenomenon associated with dynamic random access memory devices (DRAMs). Samples of 255 kbit and 1 Mbit decapped DRAMs from several manufacturers were exposed to standard alpha sources and showed a linear response with an intrinsic detection efficiency approaching 10%. Sensitivity studies were performed to evaluate the effects of DRAM operating voltage, refresh frequency and the data pattern stored prior to irradiation. The associated mechanism of soft error phenomenon is discussed. Samples were also exposed to gamma rays up to 10(5) rad to examine the total dose effect. The annealing phenomenon after gamma exposure is also presented. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1601 / 1604
页数:4
相关论文
共 50 条
  • [41] HIGH TEMPERATURE NUCLEAR PARTICLE DETECTOR
    CANEPA, PC
    CAMPBELL, RB
    MALINARIC, P
    OSTROSKI, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1964, NS11 (03) : 262 - +
  • [42] A SMALL, LINEAR, WIDE RANGE NUCLEAR RADIATION DETECTOR
    RABSON, TA
    NUCLEAR INSTRUMENTS & METHODS, 1962, 16 (01): : 37 - 38
  • [43] PROPER RESOLVING TIME OF DIAMOND DETECTOR OF NUCLEAR RADIATION
    KOZLOV, SF
    LIKHOSHE.VN
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (05): : 61 - 62
  • [44] Epitaxial gallium arsenide for nuclear radiation detector applications
    Lauter, J
    Bauser, E
    Forster, A
    Hardtdegen, H
    Hollfelder, M
    Luth, H
    Protic, D
    Zehender, S
    NUCLEAR PHYSICS B, 1995, : 381 - 385
  • [45] POSSIBILITY OF A NUCLEAR RADIATION DETECTOR BY MEANS OF ELECTROLUMINESCENT PHOSPHORS
    LOW, W
    PHYSICAL REVIEW, 1955, 98 (02): : 556 - 556
  • [46] FEASIBILITY OF A DETECTOR FOR NUCLEAR RADIATION BASED ON SUPERCONDUCTING GRAINS
    SEIDEL, W
    OBERAUER, L
    VONFEILITZSCH, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (08): : 1471 - 1476
  • [47] Onyx as radiation detector for high doses
    Teixeira, Maria Ines
    Souza, Divanizia N.
    Caldas, Linda V. E.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1894 - 1896
  • [48] Effect of the Radiation Power Density on the Sensitivity of a Diamond Detector
    M. I. Lomaev
    D. V. Rybka
    V. F. Tarasenko
    E. I. Lipatov
    M. Krishnan
    J. Thompson
    D. Parks
    Russian Physics Journal, 2004, 47 (1) : 89 - 93
  • [49] SOFT ERROR SUSCEPTIBILITY MAPPING OF DRAMS USING A HIGH-ENERGY NUCLEAR MICROPROBE
    SAYAMA, H
    KIMURA, H
    OHNO, Y
    SATOH, S
    TAKAI, M
    MICROELECTRONIC ENGINEERING, 1993, 20 (04) : 329 - 338
  • [50] Graphics DRAMs address density, performance trends