Partial discharge characteristics of inverter-fed motor coil samples under AC and surge voltage conditions

被引:63
|
作者
Hayakawa, N [1 ]
Okubo, H
机构
[1] Nagoya Univ, Dept Elect Engn, Nagoya, Aichi 464, Japan
[2] Nagoya Univ, EcoTopia Sci Inst, Nagoya, Aichi 464, Japan
关键词
motors; twisted pairs; partial discharges; inception voltage; periodic surge voltages; AC voltage;
D O I
10.1109/MEI.2005.1389265
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The partial discharge (PD) characteristics of twisted pair samples for inverter-fed motor coil under AC and surge voltage conditions were studied. The PD inception voltage (PDIV) was measured and verified to agree well with the theoretical value using electric-field analysis and Paschen's law. The PDIV under surge voltage was measured for different repetition rates. It was found that the PDIV for 60-pps repetition was lower than those for 6 pps and for the single shot. The PDIV under surge voltages was 1.6 to 1.8 times and 2.3 to 2.7 times higher than those under AC voltage application for the used and virgin samples.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 50 条
  • [32] Reduction Method of Fluctuation in Partial Discharge Inception Voltage for Inverter-Fed Rectangular Wire Motors
    Wakimoto, Toru
    Kojima, Hiroki
    Hayakawa, Naoki
    ELECTRICAL ENGINEERING IN JAPAN, 2017, 198 (02) : 3 - 10
  • [33] Experience With Online Partial-Discharge Measurement in High-Voltage Inverter-Fed Motors
    Stone, Greg C.
    Sedding, Howard G.
    Chan, Connor
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (01) : 866 - 872
  • [34] Partial discharge diagnostics on inverter-fed drives of electric vehicles
    Zajadatz, Maurizio
    Woehr, Erik
    Suriyah, Michael
    Leibfried, Thomas
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2023, 140 (7-8): : 626 - 633
  • [35] CONTROL CHARACTERISTICS OF INVERTER-FED INDUCTION-MOTOR
    KRISHNAN, R
    STEFANOVIC, VR
    LINDSAY, JF
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1983, 19 (01) : 94 - 104
  • [36] Low voltage PWM inverter-fed motor insulation issues
    Melfi, MJ
    INDUSTRY APPLICATIONS SOCIETY 51ST ANNUAL PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE, 2004, : 137 - 142
  • [37] Study on voltage distribution in windings of inverter-fed traction motor
    Tong, Lai-Sheng
    Wu, Guang-Ning
    Lin, Tong-Guang
    Zhang, Guo-Qin
    Liu, Xi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (12): : 134 - 138
  • [38] Partial Discharge Inception Characteristics and Charge Behavior for Magnet Wire under Repetitive Inverter Surge Voltage Condition
    Shimizu, Fuminobu
    Nakamura, Yusuke
    Inano, Hiroshi
    Hayakawa, Naoki
    Okubo, Hitoshi
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 195 - 195
  • [39] Partial Discharge Characteristics of Twisted Enameled Magnet Wires for Inverter-fed Random Wound Motors
    Kikuchi, Yusuke
    Miyamae, Masanori
    Fukuda, Yuki
    Nagata, Masayoshi
    Tuda, Toshihiro
    Tsutsui, Hirotsugu
    Ikegami, Tomomi
    Sakurai, Takayuki
    Yamada, Shinichiro
    Yoshimitsu, Tetsuo
    PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 125 - 127
  • [40] Characteristic Research on the Sensor for Inter-turn Partial Discharge Measurement of Inverter-fed Motor Winding
    Yuan, Pengfei
    Liu, Xuezhong
    Zhang, Tianlong
    Liu, Ping
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 13 - 17