Determination of lead in cookies by electrothermal atomic absorption spectrometry with various chemical modifiers

被引:17
|
作者
Acar, O
Kiliç, Z [1 ]
Türker, AR
机构
[1] Gazi Univ, Gazi Educ Fac, TR-06500 Ankara, Turkey
[2] Ankara Nucl Res & Training Ctr, TAEA, TR-06100 Besevlar Ankara, Turkey
[3] Gazi Univ, Sci & Art Fac, TR-06500 Ankara, Turkey
关键词
ETAAS-Zeeman background correction; lead; cookie samples; chemical modifiers;
D O I
10.1016/S0308-8146(00)00117-5
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The determination of lead in some Turkish cookies has been studied in the presence of some chemical modifiers. In order to decrease the interferences of sample matrix and to stabilize the atomic absorption signal of lead, W, Pd, W + Pd and W + Pd + tartaric acid (TA) have been tested as matrix modifier. Modifiers have been compared in terms of pyrolysis temperature, atomization and background profiles, precision and accuracy. The W + Pd + TA modifier mixture was found to be preferable for the determination of lead in cookies. The recovery and limit of detection of lead were about 99% and 1.2 mu g/l, respectively. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 50 条
  • [41] DETERMINATION OF LEAD IN FISH BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    CABRERA, C
    LORENZO, ML
    GALLEGO, C
    LOPEZ, MC
    LILLO, E
    ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 375 - 378
  • [42] The determination of lead and cadmium in biota by electrothermal atomic absorption spectrometry
    Milton, A
    Collings, SE
    Johnson, MS
    ANALES DE QUIMICA-INTERNATIONAL EDITION, 1998, 94 (4-5): : 349 - 353
  • [43] Determination of Manganese in Urine and Whole Blood Samples by Electrothermal Atomic Absorption Spectrometry: Comparison of Chemical Modifiers
    Frederico Garcia Pinto
    Ulisses Villela Rey
    Eduardo Freitas Fernandes
    Josianne Nicácio Silveira
    Leiliane Amorim
    José Bento Borba da Silva
    Analytical Sciences, 2006, 22 : 1605 - 1609
  • [44] COMPARISON OF CHEMICAL MODIFIERS FOR THE DETERMINATION OF GOLD IN BIOLOGICAL-FLUIDS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    THOMAIDIS, NS
    PIPERAKI, EA
    EFSTATHIOU, CE
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (03) : 221 - 226
  • [45] Behavior of thorium, zirconium, and vanadium as chemical modifiers in the determination of arsenic by electrothermal atomization atomic absorption spectrometry
    Castro, MA
    García-Olalla, C
    Robles, LC
    Aller, AJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) : 1 - 14
  • [46] Determination of manganese in urine and whole blood samples by electrothermal atomic absorption spectrometry: Comparison of chemical modifiers
    Pinto, Frederico Garcia
    Rey, Ulisses Villela
    Fernandes, Eduardo Freitas
    Silveira, Josianne Nicácio
    Amorim, Leiliane
    Da Silva, José Bento Borba
    Anal. Sci., 1600, 12 (1605-1609):
  • [47] Determination of manganese in urine and whole blood samples by electrothermal atomic absorption spectrometry: Comparison of chemical modifiers
    Pinto, Frederico Garcia
    Rey, Ulisses Villela
    Fernandes, Eduardo Freitas
    Silveira, Josianne Nicacio
    Amorim, Leiliane
    Borba da Silva, Jos Bento
    ANALYTICAL SCIENCES, 2006, 22 (12) : 1605 - 1609
  • [48] Comparison of chemical modifiers for the determination of vanadium in water and oil samples by electrothermal atomization atomic absorption spectrometry
    Thomaidis, NS
    Piperaki, EA
    ANALYST, 1996, 121 (02) : 111 - 117
  • [49] Study of chemical modifiers for the determination of chromium in biological materials by tungsten coil electrothermal atomic absorption spectrometry
    C. G. Bruhn
    J. Y. Neira
    M. I. Guzmán
    M. M. Darder
    J. A. Nóbrega
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 273 - 278
  • [50] Comparison of different chemical modifiers for the direct determination of arsenic in sea water by electrothermal atomic absorption spectrometry
    BermejoBarrera, P
    MoredaPineiro, J
    MoredaPineiro, A
    BermejoBarrera, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (02): : 174 - 179