Moxifloxacin hydrochloride electrochemical detection based on newly designed molecularly imprinted polymer

被引:43
|
作者
Hammam, Mennatallah A. [1 ]
Wagdy, Hebatallah A. [2 ,3 ]
El Nashar, Rasha M. [4 ]
机构
[1] German Univ Cairo, Fac Pharm & Biotechnol, Pharmaceut Chem Dept, New Cairo City, Egypt
[2] British Univ Egypt, Fac Pharm, Pharmaceut Chem Dept, POB 43, Cairo 11837, Egypt
[3] British Univ Egypt, Fac Pharm, CDRD, POB 43, Cairo 11837, Egypt
[4] Cairo Univ, Fac Sci, Chem Dept, Giza, Egypt
关键词
Avalox; Moxifloxacin hydrochloride; Molecularly imprinted polymer; Potentiometric sensor; Standard addition method; ION-SELECTIVE ELECTRODES; SENSOR; PERFORMANCE; FLUOROQUINOLONES; RECOGNITION; EXTRACTION; BINDING; AGENT; BULK;
D O I
10.1016/j.snb.2018.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Moxifloxacin HCl, a fourth generation fluoroquinolone antibacterial agent developed to treat some respiratory and dermatological infections. In this paper, a molecularly imprinted polymer was developed for specific recognition and quantification of moxifloxacin HCl in different matrices. Nine molecularly imprinted polymers were synthesized using moxifloxacin HCl as the template, methacrylic acid or 4- vinylpyridine as the functional monomers, ethylene glycol dimethacrylate as the cross linker and mixture of dimethyl sulfoxide and acetonitrile as the porogen. Following the non-covalent approach, polymers were prepared using thermal free radical bulk polymerization method. Best binding performance was for the polymer prepared using the ratio of 1:4:20 (template: functional monomer: crosslinker) in both water and methanol. This molecularly imprinted polymer was used as the recognition material in potentiometric based PVC membranes. Effect of the amount of polymer, type of plasticizer, soaking time and pH of the sample solution were studied. The sensor containing 1% MIP, 33% PVC and 66% DOP showed the nearest slope (55.9 +/- 0.86 mV/decade) to the Nernestian values over concentration range (1.0 x 10(-5)to 1.0 x 10(-2)M). It was used for the determination of moxifloxacin HCl in its pure form, Avalox tablets (400 mg/tablet) and spiked human urine samples using the standard addition method with mean percentage recoveries ranging from 96.6 to 102.8%. Lifetime of the sensor was found to be 4 months when kept dry in air.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [31] Facile construction of a molecularly imprinted polymer–based electrochemical sensor for the detection of milk amyloid A
    Zhengrong Zhang
    Shisheng Chen
    Jianluan Ren
    Fang Han
    Xiaofeng Yu
    Fang Tang
    Feng Xue
    Wei Chen
    Jielin Yang
    Yuan Jiang
    Hongmei Jiang
    Bo Lv
    Jianguo Xu
    Jianjun Dai
    Microchimica Acta, 2020, 187
  • [32] Preparation and Properties of Doxorubicin Hydrochloride Sensor Based on Molecularly Imprinted Polymer
    Zhang Yan
    Zheng Jing
    Wang Juan
    Guo Mandong
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2016, 37 (05): : 860 - 866
  • [33] Molecularly imprinted polymer-based electrochemical sensors for biopolymers
    Scheller, Frieder W.
    Zhang, Xiaorong
    Yarman, Aysu
    Wollenberger, Ulla
    Gyurcsanyi, Robert E.
    CURRENT OPINION IN ELECTROCHEMISTRY, 2019, 14 : 53 - 59
  • [34] Electrochemical Sensor Based on Molecularly Imprinted Polymer for Determination of Nonylphenol
    Liu, Benzhi
    Yang, Jinlong
    Wang, Min
    Wu, Xiangyang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (12): : 11953 - 11960
  • [35] Molecularly imprinted polymer-based electrochemical sensor for peptides
    Huang, Liming
    Hunter, Kenneth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [36] Selective electrochemical detection of bisphenol A using a molecularly imprinted polymer nanocomposite
    Ali, Haydar
    Mukhopadhyay, Soumita
    Jana, Nikhil R.
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (03) : 1536 - 1543
  • [37] Molecularly Imprinted Polymer-Hybrid Electrochemical Sensor for the Detection of β-Estradiol
    Azevedo, Sonia Des
    Lakshmi, Dhana
    Chianella, Iva
    Whitcombe, Michael J.
    Karim, Kal
    Ivanova-Mitseva, Petya K.
    Subrahmanyam, Sreenath
    Piletsky, Sergey A.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (39) : 13917 - 13923
  • [38] Electrochemical Detection of Vascular Endothelial Growth Factor by Molecularly Imprinted Polymer
    Bozal-Palabiyik, Burcin
    Lettieri, Mariagrazia
    Uslu, Bengi
    Marrazza, Giovanna
    ELECTROANALYSIS, 2019, 31 (08) : 1475 - 1481
  • [39] A versatile electrochemical sensing receptor based on a molecularly imprinted polymer
    Udomsap, Dutduan
    Branger, Catherine
    Culioli, Gerald
    Dollet, Pascal
    Brisset, Hugues
    CHEMICAL COMMUNICATIONS, 2014, 50 (56) : 7488 - 7491
  • [40] Electrochemical Quantitative Detection of Glial Fibrillary Acidic Protein Based on Molecularly Imprinted Polymer Sensor
    Wang, Tao
    Fang, Yuan
    He, Zhongzheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08): : 7341 - 7350