Moxifloxacin hydrochloride electrochemical detection based on newly designed molecularly imprinted polymer

被引:43
|
作者
Hammam, Mennatallah A. [1 ]
Wagdy, Hebatallah A. [2 ,3 ]
El Nashar, Rasha M. [4 ]
机构
[1] German Univ Cairo, Fac Pharm & Biotechnol, Pharmaceut Chem Dept, New Cairo City, Egypt
[2] British Univ Egypt, Fac Pharm, Pharmaceut Chem Dept, POB 43, Cairo 11837, Egypt
[3] British Univ Egypt, Fac Pharm, CDRD, POB 43, Cairo 11837, Egypt
[4] Cairo Univ, Fac Sci, Chem Dept, Giza, Egypt
关键词
Avalox; Moxifloxacin hydrochloride; Molecularly imprinted polymer; Potentiometric sensor; Standard addition method; ION-SELECTIVE ELECTRODES; SENSOR; PERFORMANCE; FLUOROQUINOLONES; RECOGNITION; EXTRACTION; BINDING; AGENT; BULK;
D O I
10.1016/j.snb.2018.08.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Moxifloxacin HCl, a fourth generation fluoroquinolone antibacterial agent developed to treat some respiratory and dermatological infections. In this paper, a molecularly imprinted polymer was developed for specific recognition and quantification of moxifloxacin HCl in different matrices. Nine molecularly imprinted polymers were synthesized using moxifloxacin HCl as the template, methacrylic acid or 4- vinylpyridine as the functional monomers, ethylene glycol dimethacrylate as the cross linker and mixture of dimethyl sulfoxide and acetonitrile as the porogen. Following the non-covalent approach, polymers were prepared using thermal free radical bulk polymerization method. Best binding performance was for the polymer prepared using the ratio of 1:4:20 (template: functional monomer: crosslinker) in both water and methanol. This molecularly imprinted polymer was used as the recognition material in potentiometric based PVC membranes. Effect of the amount of polymer, type of plasticizer, soaking time and pH of the sample solution were studied. The sensor containing 1% MIP, 33% PVC and 66% DOP showed the nearest slope (55.9 +/- 0.86 mV/decade) to the Nernestian values over concentration range (1.0 x 10(-5)to 1.0 x 10(-2)M). It was used for the determination of moxifloxacin HCl in its pure form, Avalox tablets (400 mg/tablet) and spiked human urine samples using the standard addition method with mean percentage recoveries ranging from 96.6 to 102.8%. Lifetime of the sensor was found to be 4 months when kept dry in air.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [1] Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Moxifloxacin
    Sadiq, Nauman
    Akbar, Muafia
    Shafique, Muhammad
    Mustafa, Ghulam
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2024, 60 (09) : 728 - 736
  • [2] Electrochemical Determination of Moxifloxacin Hydrochloride Based on Molecularly Imprinted Polymer Modified Carbon Paste Electrode
    Zhou, Qing
    Long, Ning
    Liu, Lan
    Zhai, Haiyun
    Zhu, Mingfang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (06): : 5069 - 5076
  • [3] Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Cefalexin
    Feier, Bogdan
    Blidar, Adrian
    Pusta, Alexandra
    Carciuc, Paula
    Cristea, Cecilia
    BIOSENSORS-BASEL, 2019, 9 (01):
  • [4] Molecularly imprinted conducting polymer based electrochemical sensor for detection of atrazine
    Pardieu, Elodie
    Cheap, Helene
    Vedrine, Christophe
    Lazerges, Mathieu
    Lattach, Youssef
    Garnier, Francis
    Ramita, Samy
    Pernelle, Christine
    ANALYTICA CHIMICA ACTA, 2009, 649 (02) : 236 - 245
  • [5] Molecularly Imprinted Polymer-Based Sensor for Electrochemical Detection of Cortisol
    Yulianti, Elly Septia
    Rahman, Siti Fauziyah
    Whulanza, Yudan
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [6] Molecularly imprinted polymer-based sensor for electrochemical detection of erythromycin
    Ayankojo, Akinrinade George
    Reut, Jekaterina
    Ciocan, Valeriu
    Opik, Andres
    Syritski, Vitali
    TALANTA, 2020, 209
  • [7] Novel Electrochemical Sensor Based on Molecularly Imprinted Polymer for Detection of Gefitinib
    Roushani, Mahmoud
    Tam, Kowsar
    Karazan, Zahra Mirzaei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2024, 11 (04): : 387 - 394
  • [8] Electrochemical Detection of the Anesthetic Drug Procaine Hydrochloride Based on Molecularly Imprinted Polymer/Diamond-Graphite Composite Electrode
    Zhu, Ying
    Xu, Yang
    Liu, Guangxuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (12):
  • [9] Fabrication of Molecularly Imprinted Electrochemical Sensor for Selective Detection of Propranolol Hydrochloride
    Li Hui-Xiang
    Xu Xiao-Li
    Chen Hui
    Zhang Song
    Kong Ji-Lie
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) : 817 - 822
  • [10] Potentiometric sensing of levamisole hydrochloride based on molecularly imprinted polymer
    Sadeghi, Susan
    Fathi, Fatemeh
    Abbasifar, Javad
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 158 - 164