Biomechanical investigation on refixation of tuberosities on shoulder prostheses

被引:0
|
作者
Fleischer, J. [1 ]
Schleyer, A. [2 ]
Nassutt, R. [3 ]
Grundei, H. [3 ]
Grittner, U. [4 ]
Hopp, S. J. [5 ]
机构
[1] Marienkrankenhaus St Wendel, Klin Orthopadie & Unfallchirurg, D-66606 St Wendel, Germany
[2] FH Lubeck, Biomech Labor, Lubeck, Germany
[3] ESKA Implants AG, Abt Forsch & Entwicklung, Lubeck, Germany
[4] Charite Univ Med Berlin, Inst Biometrie & Klin Epidemiol, Berlin, Germany
[5] Univ Klinikum Saarlandes, Klin Unfall Hand & Wiederherstellungschirurg, Homburg, Germany
来源
UNFALLCHIRURG | 2010年 / 113卷 / 08期
关键词
Proximal humerus fracture; Shoulder endoprosthesis; Tuberosity refixation; Biomechanical tests; Suture materials; PROXIMAL HUMERUS; PRIMARY HEMIARTHROPLASTY; GREATER TUBEROSITY; PROGNOSTIC-FACTORS; FRACTURES; ARTHROPLASTY; HEAD; FIXATION; PART;
D O I
10.1007/s00113-010-1817-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Elderly patients suffering from complex, non-reconstructable fractures of the proximal humerus are commonly treated by primary implantation of a shoulder endoprosthesis. One of the most critical factors for success or failure of treatment is still the refixation of the tuberosities. Using sheep infraspinatus tendons with attached tuberosities three different suture materials were investigated. For 2 of the suture materials 4 tests were accomplished and 5 tests were carried out for the third suture material. A material testing machine was used to perform cyclic loading tests (20 mm/min, F-min = 50 N, F-max = 100 N, respectively after 50 cycles: F-max + 50 N until failure). The results showed large variations in the average maximum forces (152.4 N for suture 1, 219.9 N for suture 2 and 452.3 N for suture 3). All tests showed a high initial lengthening and caused incision-like defects in the bone or tendon and led to failure and high displacement of the tuberosities. Due to these results suture materials have a limited usefulness for refixation of tuberosities as an increased risk of obstruction for bony consolidation can result.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 50 条
  • [31] ISOELASTIC PROSTHESES FOR SHOULDER JOINT
    BURRI, C
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1977, 345 : 601 - 601
  • [32] CONSTRUCTION OF SHOULDER AND BREAST PROSTHESES
    KNIGHT, NK
    SETZLER, DM
    SABELLA, SR
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1975, 29 (04): : 209 - 212
  • [33] REPLACEMENT PROSTHESES IN SHOULDER INJURIES
    GILFILLAN, C
    AMERICAN JOURNAL OF SURGERY, 1956, 91 (06): : 900 - 905
  • [34] 3D optical measurement of relative displacement for the tuberosities in the shoulder prosthesis
    Yao XueFeng
    Meng LiBo
    Yu LiuPing
    Zhu YiMing
    Jiang ChunYan
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2011, 54 (04) : 647 - 652
  • [35] 3D optical measurement of relative displacement for the tuberosities in the shoulder prosthesis
    XueFeng Yao
    LiBo Meng
    LiuPing Yu
    YiMing Zhu
    ChunYan Jiang
    Science China Physics, Mechanics and Astronomy, 2011, 54 : 647 - 652
  • [36] Initial Instability in Total Ankle Replacement: A Cadaveric Biomechanical Investigation of the STAR and Agility Prostheses
    McInnes, Kurtis A.
    Younger, Alastair S. E.
    Oxland, Thomas R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (17): : e147.1 - e147.8
  • [37] Influence of glenosphere diameter and lateralization on instability of reverse shoulder arthroplasty A biomechanical investigation
    Wegmann, K.
    Alikhah, A.
    Leschinger, T.
    Harbrecht, A.
    Mueller, L. P.
    Hackl, M.
    Ott, N.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2020, 15 (03): : 199 - 206
  • [38] BIOMECHANICAL COMPATIBILITY OF CRUCIATE LIGAMENT PROSTHESES
    COOKE, PH
    GOODSHIP, AE
    RITCHIE, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 496 - 496
  • [39] Biomechanical compatibility of cruciate ligament prostheses
    Cooke, P.H.
    Goodship, A.E.
    Engineering in Medicine, 1986, 15 (02): : 95 - 98
  • [40] BIOMECHANICAL ANALYSIS OF LOOSENING OF FEMUR PROSTHESES
    HUGGLER, AH
    JACOB, HAC
    SCHREIBER, A