The Non-Contact Bridging Plate.: A new fixed-angle device for the minimally-invasive treatment of fractures of the proximal humerus -: technique and preliminary results

被引:0
|
作者
Roderer, G.
Gebhard, F.
Erhardt, J.
Al-Agha, S.
AbouElsoud, M.
Kinzl, L.
机构
[1] Univ Ulm Klinikum, Zentrum Chirurg, Klin Unfallchirurg Hand Plast & Wiederherstellung, D-89075 Ulm, Germany
[2] Kantonsspital St Gallen, Klin Orthopad Chirurg & Traumatol Bewegungsappara, St Gallen, Switzerland
[3] Ain Shams Univ Hosp, Dept Orthopaed Surg, Cairo, Egypt
来源
UNFALLCHIRURG | 2007年 / 110卷 / 06期
关键词
humeral fracture; angular-stable; minimally-invasive; MIS; plate;
D O I
10.1007/s00113-006-1227-x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Fractures of the proximal humerus are common in elderly patients, especially in osteoporotic bone. Requirements for surgical treatment are high primary stability to allow early functional physiotherapy. The Non-Contact Bridging (NCB (R)) Plate for the proximal humerus (PH) is a new head locking system for treating fractures of the proximal humerus which allows minimally invasive surgery (MIS). Methods. In this contribution, the implant and technique are described, as well as the analysis of the first clinical results after 61 procedures. Results. In a mainly elderly patient population (mean: 73 years, range: 50-91 years) 61 minimally-invasive procedures were performed. The placement of screws led to a high primary stability. Primary implant failure occurred in one case (1.69%). The average constant score after 6 months was 62 points (age related mean 72). Conclusions. Using the MIS-technique, the NCB (R)-PH plate provides high primary stability, allowing functional treatment without postoperative limitations. The first clinical results show a good functional outcome in a mainly elderly patient population.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 15 条
  • [1] Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate
    Hessler, C.
    Schmucker, U.
    Matthes, G.
    Ekkernkamp, A.
    Guetschow, R.
    Eggers, C.
    UNFALLCHIRURG, 2006, 109 (10): : 867 - +
  • [2] Fixed-angle plate fixation in simulated fractures of the proximal humerus: A biomechanical study of a new device
    Chudik, SC
    Weinhold, P
    Dahners, LE
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (06) : 578 - 588
  • [3] Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?
    Kim, Beom-Soo
    Kim, Du-Han
    Choi, Jung-Hoon
    Choi, Byung-Chan
    Cho, Chul-Hyun
    MEDICINA-LITHUANIA, 2022, 58 (03):
  • [4] Can the outcome of proximal humeral fractures be improved using a minimally invasive surgical technique for fixed-angle plate osteosynthesis?
    Ketterl, Rupert
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2013, 8 (03): : 158 - 164
  • [5] Minimally invasive application of the non-contact-bridging (NCB) plate to the proximal humerus: An anatomical study
    Roederer, Goetz
    AbouElsoud, Maged
    Gebhard, Florian
    Boeckers, Tobias M.
    Kinzl, Lothar
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (09) : 621 - 627
  • [6] A new osteosynthesis device for the treatment of proximal humerus fractures. Description of the technique and preliminary results.
    Russo R.
    Lombardi L.V.
    Ciccarelli M.
    Giudice G.
    Cautiero F.
    La Chirurgia degli Organi di Movimento, 2008, 91 (1): : 27 - 34
  • [7] Surgical treatment of two-part fractures of the proximal humerus: Comparison of fixed-angle plate osteosynthesis and Zifko nails
    Matziolis, Doerte
    Kaeaeb, Max
    Zandi, Souska Sophie
    Perka, Carsten
    Greiner, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1041 - 1046
  • [8] Fixation of periprosthetic femur fractures with the less invasive stabilization system (LISS) - a new minimally invasive treatment with locked fixed-angle screws
    Kolb, W
    Guhlmann, H
    Friedel, R
    Nestmann, H
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 53 - 59
  • [9] Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant
    Erhardt, J. B.
    Grob, K.
    Roderer, G.
    Hoffmann, A.
    Forster, T. N.
    Kuster, M. S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) : 409 - 416
  • [10] Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant
    J. B. Erhardt
    K. Grob
    G. Roderer
    A. Hoffmann
    T. N. Forster
    M. S. Kuster
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 409 - 416