Is Device Removal Necessary after Fixed-Angle Locking Plate Osteosynthesis of Proximal Humerus Fractures?

被引:2
|
作者
Kim, Beom-Soo [1 ]
Kim, Du-Han [1 ]
Choi, Jung-Hoon [2 ]
Choi, Byung-Chan [1 ]
Cho, Chul-Hyun [1 ]
机构
[1] Keimyung Univ, Dongsan Hosp, Dept Orthoped Surg, Sch Med, Daegu 42601, South Korea
[2] Bogang Hosp, Dept Orthoped Surg, 102 Wolbae Ro, Daegu 42801, South Korea
来源
MEDICINA-LITHUANIA | 2022年 / 58卷 / 03期
基金
新加坡国家研究基金会;
关键词
shoulder; proximal humerus fracture; locking plate; device removal; INTERNAL-FIXATION; ARTHROSCOPIC REMOVAL; HARDWARE REMOVAL; CAPSULAR RELEASE; IMPLANT REMOVAL; OPEN REDUCTION; COMPLICATIONS;
D O I
10.3390/medicina58030382
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The aim of this study was to evaluate whether device removal in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture improves the clinical outcomes. Materials and Methods: Seventy-one patients who underwent fixed-angle locking plate osteosynthesis of a proximal humerus fracture were included. Thirty-three patients underwent device removal at a mean time of 10.4 months after index surgery (removal group). Thirty-eight patients who retained the device after index surgery (retention group) were included in the control group. Visual analog scale (VAS) pain score, University of California at Los Angeles (UCLA) score, American Shoulder and Elbow Surgeons (ASES) score, and range of motion (ROM) were evaluated pre- and postoperatively. Results: At the final follow-up, mean UCLA score, ASES score, and all ROMs were significantly higher in the removal group compared to the retention group (p < 0.001). However, no significant difference in mean VAS pain score was observed between the two groups. Comparison of the clinical outcomes before and after device removal surgery showed significant improvement in all clinical scores and ROMs after device removal (p < 0.001). Conclusions: Device removal surgery in symptomatic patients following locking plate osteosynthesis of a proximal humerus fracture can result in significant improvement in functional outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Biomechanical investigation of fixed-angle plate osteosynthesis of the proximal humerus
    Roederer, G.
    AbouElsoud, M.
    Gebhard, F.
    Claes, L.
    Aschoff, A. J.
    Kinzl, L.
    UNFALLCHIRURG, 2010, 113 (02): : 133 - 138
  • [2] Locking plate osteosynthesis for fractures of the proximal humerus
    Lungershausen, W
    Bach, O
    Lorenz, CO
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 28 - 33
  • [3] Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?
    Helwig, Peter
    Bahrs, Christian
    Epple, Bjoern
    Oehm, Justus
    Eingartner, Christoph
    Weise, Kuno
    ACTA ORTHOPAEDICA, 2009, 80 (01) : 92 - 96
  • [4] Results after treatment of instable fractures of the proximal humerus using a fixed-angle plate
    Hessler, C.
    Schmucker, U.
    Matthes, G.
    Ekkernkamp, A.
    Guetschow, R.
    Eggers, C.
    UNFALLCHIRURG, 2006, 109 (10): : 867 - +
  • [5] Fixed-angle plate fixation in simulated fractures of the proximal humerus: A biomechanical study of a new device
    Chudik, SC
    Weinhold, P
    Dahners, LE
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (06) : 578 - 588
  • [6] Proximal humerus fracture. Is fixed-angle plate osteosynthesis superior to conservative treatment?
    Krettek, C.
    Wiebking, U.
    UNFALLCHIRURG, 2011, 114 (12): : 1059 - 1067
  • [7] Surgical treatment of two-part fractures of the proximal humerus: Comparison of fixed-angle plate osteosynthesis and Zifko nails
    Matziolis, Doerte
    Kaeaeb, Max
    Zandi, Souska Sophie
    Perka, Carsten
    Greiner, Stefan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1041 - 1046
  • [8] Arthroscopic implant removal after fixed-angle plate osteosynthesis of the proximal humerus. Technique and initial results in comparison to open implant removal.
    Katthagen, J. C.
    Jensen, G.
    Hennecke, D.
    Lill, H.
    Voigt, C.
    UNFALLCHIRURG, 2012, 115 (01): : 47 - 54
  • [9] Fixed-angle plate fixation of proximal humeral fractures
    Voigt, C.
    Lill, H.
    TRAUMA UND BERUFSKRANKHEIT, 2005, 7 : S10 - S14
  • [10] Fixed-angle locking proximal humerus plate: an evaluation of functional results and implant-related outcomes
    Pak, Ponnaren
    Eng, Kevin
    Page, Richard S.
    ANZ JOURNAL OF SURGERY, 2013, 83 (11) : 878 - 882